Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MERSEN Search Results

    MERSEN Datasheets (5)

    Mersen USA Newburyport-MA L.L.C.
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    AJT100N
    Mersen USA Newburyport-MA L.L.C. 600VAC 100A CLASS J TD FUSE Original PDF 252.35KB 2
    AJT200N
    Mersen USA Newburyport-MA L.L.C. 600VAC 200A CLASS J TD FUSE Original PDF 252.35KB 2
    AJT30N
    Mersen USA Newburyport-MA L.L.C. 600VAC 30A CLASS J TD FUSE Original PDF 252.35KB 2
    ATDR30
    Mersen USA Newburyport-MA L.L.C. CC TD FUSE 600V 30A ATDR Original PDF 137.05KB 2
    TRS30R
    Mersen USA Newburyport-MA L.L.C. 600V 30A 5X13/16 TD FUSE Original PDF 286.11KB 2

    MERSEN Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    LC1-D09 01

    Abstract: ED63A 8536SC03
    Contextual Info: Mersen UltraSafeTM Fuse Modules have a unique, compact design suited for use with 45mm wide IEC contactors and motor starters. The USFMCC I has a stand-alone short circuit current rating (SCCR) of 200kA. Mersen Class CC motor protection fuses offer time delay characteristics in a compact body with a 200kA interrupting rating.


    Original
    200kaul508a600vaccht-sccrusfm-01+3lc1-d09 01ed63a8536sc03 PDF

    CNL500

    Contextual Info: Forklift Truck Fuses Mersen Forklift Truck and Battery Isolator fuses are specially designed for the heavy duty loads associated with DC battery powered equipment such as forklift trucks, hand trucks, motorized work platforms, and other DC battery operated systems.


    Original
    cnl500 PDF

    Contextual Info: New ratings now available! HP6J 600V DC Class J Photovoltaic Fuses About the HP6J Fuse Mersen’s HP6J photovoltaic PV fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to


    Original
    600vdc61016j62001j62011j+464031j64011j6631j6611j PDF

    9F61BWW460

    Abstract: 9F60BHH905 9F60BDD001 transformer e33
    Contextual Info: Potential Transformer Amp-Trap and 9F60 Series PT Fuses 0.625kV – 2.4kV – 2.75kV – 4.8kV – 5.0kV – 5.5kV – 7.2kV – 8.25kV and 15.5kV ferrule mounted fuses: Mersen PT fuses are current-limiting fuses with high interrupting rating, used for the


    Original
    625kv9f60bhh9059f61adg1019f60bhh001+89f60bhh0029f60bhh003120ka9f61bww4609f61bnw4509f61adj1019f60bdd001transformer e33 PDF

    9F60DMH905

    Contextual Info: Transformer Protection Amp-Trap CS-3 Series and 9F60/9F62 Series 2.75kV, 5.5kV, 8.25kV, 15.5kV, 25.8kV and 38kV Ferrule Mounted Fuses Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can


    Original
    9f60/9f62a155f1d0r0-65ea155f1d0r0-100ea155f2d0r0-175e+5a155f2d0r0-200ea155f2d0r0-150ea155f2d0r0-125ea155f1d0r0-80e9f60dmh905 PDF

    Contextual Info: TGL, TGN, TGS Telecommunications Fuses Mersen Telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment, rectifiers, distribution switching panels, battery back-up modules, power supplies and


    Original
    170vdc100ka1-600atgs25+5tgs30tgs40tgs50tgs10tgs60 PDF

    ETI fuse

    Contextual Info: HP10NH1 1000V DC Size NH1 Photovoltaic Fuses About the HP10NH1 Fuse Mersen’s HP10NH1 photovoltaic PV fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to


    Original
    hp10nh11000vdchp10nh1gpv50z1028283+4hp10nh1gpv63a1028284hp10nh1gpv80eti fuse PDF

    mersen

    Abstract: inventory
    Contextual Info: Get Control of Your Inventory and Costs Fact Sheet Fuse Control TM Mersen’s Fuse Control program is a powerful combination of circuit protection products and services designed to help you get control of your plant inventory, operating costs, code compliance and


    Original
    300kafs-fc-002merseninventory PDF

    HP10M15

    Abstract: US101HEL HP10M10 HP10M20 HP10M4 Photovoltaic US101IHEL HP10M12 HP10M7 HP10M5
    Contextual Info: HP10M 1000VDC Photovoltaic Fuses Engineered to protect photovoltaic applications Mersen’s HP10M photovoltaic PV fuse series was engineered and designed specifically for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal for continuous temperature and current cycling withstand adding to


    Original
    hp10m1000vdchp10m1hp10m7+10hp10m8hp10m10hp10m15us101helhp10m20hp10m4photovoltaicus101ihelhp10m12hp10m5 PDF

    PCF30/50-H

    Contextual Info: PCF Fast-Acting PC Mount Fuses Fast-acting fuses for direct mounting on printed circuit boards. Mersen’s PCF series of fast-acting direct-mountable fuses addresses the increasing need for electrical protection at the PC board as current and voltage requirements


    Original
    pcf10-spcf12-spcf15-spcf20-s+7pcf25-spcf30-spcf30-rpcs40-rpct30-rpcf30-hpcf30/50-h PDF

    Contextual Info: Capacitor Protection Amp-Trap and 9F60 Series Medium voltage capacitor fuses: Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses


    Original
    c37-41a430c6-75a430c8-75a430c10-75+6a430c12-75a430c18-75a430c20-75a430c25-75a430c30-75a430c35-75 PDF

    Contextual Info: A4BX Welder Protectors Welder protectors Mersen Welder Protectors are special purpose limiters used to provide isolation of faulted welding equipment and protection for the cable drop supplying the welder. Welder Protectors have a high thermal capacity and are less affected by high ambient


    Original
    a4bx100-150a4bx125-150a4bx150-150a4bx200-150+4a4bx200-150ja4bx225-1504bx600-150600vac200ka PDF

    S 20 KV 431

    Contextual Info: Capacitor Protection Amp-Trap and 9F60 Series Medium voltage capacitor fuses: Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses


    Original
    c37-419f60rjd0409f60rjf0159f60rjf040+29f60rjf025s 20 kv 431 PDF

    9F62FCB300

    Abstract: A055F1D0R0100E A055F2D0R0-450E
    Contextual Info: Transformer Protection Amp-Trap CS-3 Series and 9F60/9F62 Series 2.75kV, 5.5kV, 8.25kV, 15.5kV, 25.8kV and 38kV Ferrule Mounted Fuses Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can


    Original
    9f60/9f629f60fjd0409f60fjd0309f60djd025+99f60djd0209f60djd0159f60djd0059f60djd0039f60djd0029f60djd0019f62fcb300a055f1d0r0100ea055f2d0r0-450e PDF

    Contextual Info: A60C Low Voltage Capacitor Fuses 600V Low Voltage Capacitor Fuses Mersen low voltage capacitor fuses provide advanced safety for power correction and harmonic filtering equipment. A capacitor fuse isolates a shorted capacitor before it can damage surrounding equipment or personnel. Typical capacitor failures occur


    Original
    a60c35-121tia60c40-121a60c40-121tia60c50-121+6a60c50-121tia60c60-121a60c60-121tia60c75-121tia60c80-121a60c80-121ti PDF

    SP670PV

    Abstract: STP1000YPVM SP350PV IEC 61643-1 SP745PV STP600YPVM microswitch subminiature PV charge controllers 600C 4047 BE
    Contextual Info: Data Sheet Surge-Trap PV Pluggable SPD About the Surge-Trap PV Pluggable SPD This Surge-Trap SPD provides advanced overvoltage protection to photovoltaic systems by utilizing Mersen’s patented TPMOV design. The Surge-Trap Pluggable base is designed to be mounted on 35mm DIN-rail


    Original
    stp600ypvmstp1000ypvmstp1200ypvmds-stp-pv-002+8sp670pvsp350pviec 61643-1sp745pvmicroswitch subminiaturepv charge controllers600c4047 be PDF

    Contextual Info: Capacitor Protection Amp-Trap and 9F60 Series Medium voltage capacitor fuses: Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting operating without noise or discharge and are designed to be used indoors in a general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses


    Original
    c37-41a300c95-20a300c100-20a300c115-20+6a300c125-20a300c130-20a300c150-20a300c175-20a300c50-60a300c60-60 PDF

    Contextual Info: Motor Protection Amp-Trap and 9F60 Series 2.4kV, 2.54kV, 4.8kV, 5.08kV and 7.2kV Ferrule mounted fuses: Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers.


    Original
    9f60lcl3099f60mcl3249f60mcl3189f60lcl312+69f60lcl3049f60lcl3039f60mcb5189f60lcb5129f60lcb5049f60lcb503 PDF

    A155B

    Contextual Info: Transformer Protection Amp-Trap and 9F62 Bolt-In Series 5.0kV, 5.5kV, 7.2kV, 8.25kV, and 15.5kV Bolt-In fuses: Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can


    Original
    9f62ked3009f61ahg0019f61chl009a155b PDF

    30321 mersen

    Contextual Info: DCT Special Purpose Midget Fuses Mersen DCT fuses were developed to meet requirements coming from new applications such as protection of photovoltaic cells, multi meters and compact on board traction equipment for auxiliary circuits. This high performance DC fuse in its


    Original
    dct10-2dct12-2dct15-2dct20-2+5dct25-2dct30-2e6031410x38mm30321 mersen PDF

    30321 mersen

    Contextual Info: VSP MOV Protector Fuse Surge Suppression Fuses Mersen surge suppression fuses are specially designed to address the protection of SPD systems. Our surge suppression fuses have been specially designed to withstand 8x20 µSec surge pulses without opening, allowing the SPD system to


    Original
    600vac200ka5-100ka60305j+760315j60325j60306j60316j60326j60307j30321 mersen PDF

    Contextual Info: A2Y/A6Y Form 600 Form 600 fuses Mersen Form 600 fuses are the original current-limiting fuses, pre-dating all the standards. Their 500V DC rating through 600A is a useful feature for special fusing applications. Form 600 fuses provide a high degree of current limitation in AC and DC


    Original
    a2y200-3a6y200-3a2y200-4a6y200-4+6a6y200-5a6y225-3a6y225-4vac/50025-600a50-1200a PDF

    HP6M

    Abstract: ELEVATOR Elevator motors Ferraz Shawmut HP10M INVERTER TRANSFORMERS design COMBINER BOX wiring shunt trip Ferraz Shawmut SPD elevator inverter
    Contextual Info: Circuit Protection Products Electricity runs the world. At Mersen formerly Ferraz Shawmut , we keep it safe and reliable with a comprehensive range of products and services to protect your products and systems and the people who use them. Explore what we can do for you!


    Original
    lc-prdcts-001hp6melevatorelevator motors+7ferraz shawmuthp10minverter transformers designcombiner boxwiring shunt tripferraz shawmut spdelevator inverter PDF

    Contextual Info: gl-gG, aM NH Dimension Knife-Blade Fuse-Links NH Dimension Knife-Blade fuse-links, fuse bases, and accessories Mersen NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator


    Original
    120ka5-100a25-315a250/300a+215-425a00-800a PDF