transistor k43
Abstract: K43A K43B K43c NC-SPDT MIL-R-83725 nok43 CII Technologies relay
Contextual Info: 10 kV Kilovac K43A, K43B Features: Make & Break Load Switching 10 kV, 25 Amps continuous current relay RF ratings to 32 MHz Vacuum dielectric for power switching low current loads 2 million cycle mechanical life QPL version available, M83725/17 &
|
Original
|
m83725/17m83725/10mil-r-83725m83725/16+7transistor k43k43ak43bk43cnc-spdtnok43cii technologies relay
|
PDF
|
k47a
Abstract: MIL-R-83725 5510-00 kilovac k47b
Contextual Info: 8 kV Kilovac K47A Make & Break Load Switching Kilovac K47B Make & Break Load Switching Features: Widely used in antenna coupler applications Short actuator, low profile, 8 kV relay Vacuum dielectric for power switching low current loads Normally open contacts
|
Original
|
mil-r-83725m83725/18-003k47a5510-00+1kilovac k47b
|
PDF
|
RJ1A-26S
Abstract: RJ1H RJ1H-26S MIL-R-83725 RJ1H-15S RJ1H-26N877 M83725 JENNINGS rj1a26s
Contextual Info: SPDT Vacuum Relays RJ 1A, 1H SPECIFICATIONS 5 kV n Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF)
|
Original
|
rj1a-26smil-r-16m83725/5-001m83725/4-001+9m83725/4-002rj1h-26srj1h-26n877rj1hmil-r-83725rj1h-15sm83725jenningsrj1a26s
|
PDF
|
kilovac
Abstract: kilovac hc-3 MIL-R-83725 hc-3
Contextual Info: 3.5 kV Kilovac HC-1 Kilovac HC-3 No Load Switching Features: Make & Break Load Switching HC-1 Widely used for RF applications Vacuum dielectric for low leakage current applications Copper contacts for high current capability Not designed for power switching
|
Original
|
mil-r-83725m83725/5-001kilovackilovac hc-3+1hc-3
|
PDF
|
kilovac
Abstract: MIL-R-83725 H-17 H-19
Contextual Info: 20 / 25 kV Kilovac H-19 Features: Make & Break Load Switching 20 kV operating voltage Vacuum dielectric and tungsten contacts for power switching low current loads Double pole, double throw contacts Available with corona shield connectors Meets requirements of MIL-R-83725
|
Original
|
mil-r-83725m83725/2kilovach-17+1h-19
|
PDF
|
RF65-12S
Abstract: RF62-26S JENNINGS rfid-26s JENNINGS RF72-26S RF63-26S RF63 MIL-R-83725 RF65D-12S RF62 rf622
Contextual Info: SPDT Vacuum Relays RF 62, 63, 65 SPECIFICATIONS Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf65-12srf62-26sm83725/16-002m83725/16-004+12m83725/16-001m83725/16-003m83725/13-001m83725/13-002rf63-26sjennings rfid-26sjennings rf72-26srf63mil-r-83725rf65d-12srf62rf622
|
PDF
|
kilovac
Contextual Info: KILOVAC High Voltage Relays and Contactors Table of Contents High Voltage DC Contactors Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4, 7-5 MAP Aerospace Military Contactors MAP101 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6, 7-7
|
Original
|
map101map100map200map201+1kilovac
|
PDF
|
kilovac
Abstract: MIL-R-83725 SF6 gas
Contextual Info: 3.5 kV Kilovac HC-1 Kilovac HC-3 No Load Switching Features: Make & Break Load Switching HC-1 Widely used for RF applications Vacuum dielectric for low leakage current applications Copper contacts for high current capability Not designed for power switching
|
Original
|
mil-r-83725m83725/5-001/12vdc12vdc+4/115vdc115vdckilovacsf6 gas
|
PDF
|
Kilovac K41C
Abstract: K41A MIL-R-83725
Contextual Info: 5 kV Kilovac K41A, K41B Kilovac K41C Features: Make & Break Load Switching High current carry rating Vacuum dielectric for power switching low current loads Glazed ceramics for low current leakage Compact, space-saving design Meets requirements of MIL-R-83725
|
Original
|
mil-r-83725m83725/21m83725/22m83725/23+2kilovac k41ck41a
|
PDF
|
rf61-26s
Abstract: RF60D-26S MIL-R-83725 RF61 RF60D 11002 JENNINGS RF72-26S RF61D-26S RF60 TUNED ANTENNA
Contextual Info: SPDT Vacuum Relays RF 60, 61, 64 SPECIFICATIONS Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf61-26srf64-12srf60-26sm83725/11-001+14m83725/11-002m83725/12-001m83725/12-002m83725/12-003m83725/12-004rf60d-26smil-r-83725rf61rf60d11002jennings rf72-26srf61d-26srf60tuned antenna
|
PDF
|
Kilovac K41C
Abstract: K41A MIL-R-83725 K41B
Contextual Info: 5 kV Kilovac K41A, K41B Kilovac K41C Features: Make & Break Load Switching High current carry rating Vacuum dielectric for power switching low current loads Glazed ceramics for low current leakage Compact, space-saving design Meets requirements of MIL-R-83725
|
Original
|
mil-r-83725m83725/21m83725/22m83725/23+3kilovac k41ck41ak41b
|
PDF
|
RF5A
Abstract: rf6a26s rf6a-26s RF6A RF44-26S RF5A-26S RF44 RF6C RF5AD-26S RF6C-12S
Contextual Info: SPST Vacuum Relays RF 5A, 5C, 6A, 6C, 44 SPECIFICATIONS Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf5c-12srf6a-26srf5a-26srf6c-12s+10rf44-26sm83725/18-001m83725/18-002rf44d-26srf5arf6a26srf6arf44rf6crf5ad-26s
|
PDF
|
RF1D
Abstract: RF1D-26S RF1G rf1e-26s COIL-12VDC ms flange M83725/3-002 MIL-R-83725 RF1G-12S RF1GD-12S
Contextual Info: SPDT Vacuum Relays RF 1D, 1E, 1G SPECIFICATIONS Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf1d-26smil-r-83725rf1e-26srf1g-12s+7rf1gd-12sm83725/3-001m83725/3-002rf1drf1gcoil-12vdcms flange
|
PDF
|
JENNINGS
Abstract: RF48 RF46 MIL-R-83725 RF48D-12S JENNINGS RF72-26S RF48-12S rf42
Contextual Info: SPST Vacuum Relays RF 41, 42, 46, 48 SPECIFICATIONS MODEL NUMBER Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf46-26srf42-26srf41-26sm83725/7-001+12m83725/7-002m83725/8-001m83725/8-002rf41d-26sjenningsrf48rf46mil-r-83725rf48d-12sjennings rf72-26srf48-12srf42
|
PDF
|
|
|
dc relay economizing coil
Abstract: S06CBA kilovac kc-2
Contextual Info: KILOVAC High Voltage Relays and Contactors Table of Contents High Voltage DC Contactors Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4, 7-5 MAP Aerospace Military Contactors MAP101 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6, 7-7
|
Original
|
map101map100map200map201+3dc relay economizing coils06cbakilovac kc-2
|
PDF
|
K41P
Abstract: kilovac K41R DSA004594 MIL-R-83725
Contextual Info: 5 kV Kilovac K41P Features: Make & Break Load Switching Fast, 6 millisecond operate time Vacuum dielectric for power switching low current loads Latching actuator for low power consumption Ideal for frequency agile communication systems Meets requirements of MIL-R-83725
|
Original
|
mil-r-83725m83725/24k41pkilovac+2k41rdsa004594
|
PDF
|
RF51-26S
Abstract: JENNINGS RF72-26S RF57 RF51D-26S RF50 RF5616 RF57D-12S RF50D rf56 MIL-R-83725
Contextual Info: SPST Vacuum Relays RF 50, 51, 56, 57 SPECIFICATIONS Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf56-12srf56d-12srf57-12srf57d-12s+11rf50-26srf50d-26srf51-26srf51d-26sjennings rf72-26srf57rf50rf5616rf50drf56mil-r-83725
|
PDF
|
RB1D-26N400
Abstract: RB1D-26N300 RB1D jennings rf10b-26s MIL-R-83725 RF10B-26S JENNINGS RB1D RB1E-26N400 RB1D-26S JENNINGS
Contextual Info: SPDT Vacuum Relays RF 10 SPECIFICATIONS 20 kV Model Number Test Voltage kV Peak 60 Hz Rated Operating Voltage (kV Peak) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Continous Current, Carry (Amps, RMS) DC or 60 Hz 2.5 MHz 16 MHz 32 MHz Contact Capacitance (pF) Between Open Contacts
|
Original
|
rf10brf10b-26sm83725/1-004m83725/1-005+15m83725/1-006m83725/1-001m83725/1-002m83725/1-003m83725/15-001m83725/15-002rb1d-26n400rb1d-26n300rb1djennings rf10b-26smil-r-83725jennings rb1drb1e-26n400rb1d-26sjennings
|
PDF
|