LUCENT GALAXY CONT Search Results
LUCENT GALAXY CONT Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| HM2LS22A8JLF | Amphenol Communications Solutions | HM2LS22A8JLF-SHIELDING CONT TYPE, HM2 | |||
| HM2LS25A8JLF | Amphenol Communications Solutions | HM2LS25A8JLF-LOWER SHIELD CONT, HM2 | |||
| ICD26S13E4GX00LF | Amphenol Communications Solutions | D-Sub High Density Board Mount Connectors, Input Output Connectors, 26 way, Right Angle, Solder socket, >200 Mating Cycles, Harpoons + Insert UNC 4 - 40 + Elec cont | |||
| ICD44S13E6GL00LF | Amphenol Communications Solutions | D-Sub High Density Board Mount Connectors, Input Output Connectors, 44 way, Right Angle, Solder socket, >500 Mating Cycles, Harpoons + Insert M3 + Elec cont | |||
| ICD44S13E4GX00LF | Amphenol Communications Solutions | D-Sub High Density Board Mount Connectors, Input Output Connectors, 44 way, Right Angle, Solder socket, >200 Mating Cycles, Harpoons + Insert UNC 4 - 40 + Elec cont |
Documents mentioning LUCENT GALAXY CONT
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| galaxy power | Galaxy Power System 2424 (GPS 2424) H569-437 User’s Guide Select Code 167-792-159 Comcode 108305251 Issue 5 June 2000 © 2000 Lucent Technologies User’s Guide Select Code 167-792-159 Comcode 108305251 Issue 5 June 2000 Lucent Technologies Galaxy Power System 2424 |
Original | ||||
| Galaxy Power System Verification Procedures | Galaxy Power System Verification Procedures User’s Guide Select Code 167-792-010 Comcode 108639659 Issue 1 March 2000 © 2000 Lucent Technologies User’s Guide Select Code 167-792-010 Comcode 108639659 Issue 1 March 2000 Galaxy Power System Verification Procedures |
Original | ||||
| h569-429 | Product Manual H569-429 Select Code 167-792-120 Comcode 107966541 Issue 2 June 1998 Lucent Technologies 600-Ampere, 140-Volt Galaxy Control and Distribution Bay for New and Retrofit 4ESS™ Applications Notice: Every effort was made to ensure that the information in this |
Original | ||||
| Lucent Technologies Power Systems Literature | Lucent Technologies Power Systems Literature Selection Guide August 2000 Lucent Technologies Power Systems Literature Selection Guide TITLE STATUS DATE August - 2000 DOCUMENT # CONTENTS PAGE — INTEGRATED CIRCUITS — POWER PRODUCTS… 3 |
Original | ||||
| galaxy power | Product Manual 167-792-150 Comcode 107933376 Issue 1 November 1996 Galaxy Power System 4824 (GPS 4824) Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change. |
Original | ||||
| evolutionary control system | ECS Battery Plant 500G Series (ECS) –48 V Output, 600 A Maximum The Evolutionary Control System (ECS) 500 G Series integrates advanced rectifier technology and a modular plug-in design in an efficient, easy-to-manage battery plant. ■ Microprocessor and datalogger |
Original | ||||
| 596a | GALAXY Switchmode Rectifier 596 Series Model 596A: –48 Vdc, 50 Adc, 208 Vac/240 Vac Model 596B: +24 Vdc, 100 Adc, 208 Vac/240 Vac The new GALAXY Switchmode Rectifier 596 Series provides the highest quality dc power for telecommunications and data processing systems and their |
Original | ||||
| galaxy power | dc Distribution and Battery Connections for GPS 4848, GPS 4812, GPS 4824, and GPS 2424 A variety of dc distribution and battery connection modules are available for use with the GALAXY Power Systems family to meet a wide range of applications. Preconfigured dc Distribution |
Original | ||||
| j85500a-2 | Lineage 2000® Battery Plant J85500A-2 Product Manual Select Code 167-790-032 Comcode 108190596 Issue 4 April 1999 © 1999 Lucent Technologies Product Manual Select Code 167-790-032 Comcode 108190596 Issue 4 April 1999 Lineage® 2000 Battery Plant J85500A-2 |
Original | ||||
| VOL.3 JAN.-MAR.’00 ™ E n e r g y S y s t e m s D | VOL.3 JAN.-MAR.’00 ™ E n e r g y S y s t e m s D i v i s i o n One.Tel selects Lucent for Australia network When One.Tel of Australia was ready to roll out a GSM network in its hometown of Sydney, it selected Lucent Technologies as its partner in technology. One.Tel is a global |
Original | ||||
| 596d | Galaxy 596D SMR Rectifier -48Vdc, 100Adc, 208 Vac / 240 Vac Packing More Power and Efficiency into Small Spaces The Galaxy 596D SMR integrates the latest Switchmode technology with superior power, protection, and control features in a compact, cost-efficient power-conversion system. It is the newest in the line of reliable |
Original | ||||
Product Manual J87132B-2 Select Code 169-792-100 Comcode 107940108 Issue 3 March 1998 Lucent Technologies 140-Volt, 140-Ampere, 60-Hertz Ferroresonant Rectifier Notice: Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. |
Original | |||||
| j85503b-2 | Lineage® 2000 200-Ampere, 60-Hertz Ferroresonant Rectifier J85503B-2 Product Manual Select Code 169-790-128 Comcode 107666356 Issue 8 January 1999 ©1999 Lucent Technologies Product Manual J85503B-2 Select Code 169-790-128 Comcode 107666356 Issue 8 January 1999 |
Original | ||||
| galaxy power system | Galaxy Power System Verification Procedures User’s Guide Select Code 167-792-010 Comcode 108639659 Issue 3 January 2008 User’s Guide Select Code 167-792-010 Comcode 108639659 Issue 3 January 2008 Galaxy Power System Verification Procedures Notice: The information, specifications, and procedures in this manual are |
Original | ||||
|
|
||||||
Lineage® 2000 400-Ampere, 50-Hertz Ferroresonant Rectifier J85603C-2 Product Manual Select Code 169-791-113 Comcode 107100828 Issue 7 March 1999 © 1999 Lucent Technologies Product Manual Select Code 169-791-113 Comcode 107100828 Issue 7 March 1999 Lucent Technologies |
Original | |||||
| j85503a | Lineage® 2000 100-Ampere, 60-Hertz Ferroresonant Rectifier J85503A-1 Product Manual Select Code 169-790-119 Comcode 107021818 Issue 6 October 1998 © 1998 Lucent Technologies Product Manual J85503A-1 Select Code 169-790-119 Comcode 107021818 Issue 6 October 1998 |
Original | ||||
| j85502c-1 | Lineage® 2000 125-Ampere, 60-Hertz Ferroresonant Rectifier J85502C-1 Product Manual Select Code 169-790-121 Comcode 107044992 Issue 8 July 1999 © 1999 Lucent Technologies Product Manual Select Code 169-790-121 Comcode 107044992 Issue 8 July 1999 Lineage® 2000 |
Original | ||||
| ne075ac24 | Infinity NE Rectifier NE075AC24 24Vdc, 75Adc, 208Vac/240Vac Packing More Power and Efficiency into Small Spaces The INFINITY NE Switchmode Rectifier NE075AC24 integrates the latest Switchmode technology with superior power density, protection and control features in a compact, cost efficient power conversion system. |
Original | ||||
| ne030dc48 | Infinity NE DC/DC Converter NE030DC48 -48Vdc, 30Adc Output, 24Vdc Input Packing More Power and Efficiency into Small Spaces The INFINITY NE DC/DC converter NE030DC48 integrates the latest Switchmode technology with superior power density, protection and control features in a compact, cost efficient power conversion system. |
Original | ||||
| ne075dc24 | Infinity NE DC/DC Converter NE075DC24 -24Vdc,75Adc Output, 48Vdc Input Packing More Power and Efficiency into Small Spaces The INFINITY NE DC/DC converter NE075DC24 integrates the latest Switchmode technology with superior power density, protection and control features in a compact, cost efficient power conversion system. |
Original | ||||
| ne050ac48 | Infinity NE Rectifier NE050AC48 -48Vdc, 50Adc, 208Vac/240Vac Packing More Power and Efficiency into Small Spaces The INFINITY NE Switchmode Rectifier NE050AC48 integrates the latest Switchmode technology with superior power density, protection and control features in a compact, cost efficient power conversion system. |
Original | ||||
| ne075dc24 | Infinity NE DC/DC Converter NE075DC24 -24Vdc,75Adc Output, 48Vdc Input Packing More Power and Efficiency into Small Spaces The INFINITY NE DC/DC converter NE075DC24 integrates the latest Switchmode technology with superior power density, protection and control features in a compact, cost efficient power conversion system. |
Original | ||||
| galaxy gateway | Galaxy Gateway v3 Web-Based Remote Monitoring and Control Product Manual Select Code 193-104-106 Comcode 108728163 Issue 9 January 2008 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear |
Original | ||||
| j85568d-1 | Product Manual J85568D-1 Select Code 157-005-101 Comcode 106991391 Issue 5 March 1998 Lucent Technologies Lineage® 2000 Eight-Load BDFB (Battery Distribution Fuse Bay) and Six-Load PDF (Power Distribution Frame) Notice: Every effort was made to ensure that the information in this |
Original | ||||
| EPS 4802B Battery Plant Product Manual Select | EPS 4802B Battery Plant Product Manual Select Code 167-793-101 Comcode 108621293 Issue 2 August 2000 © 2000 Lucent Technologies Product Manual Select Code 167-793-101 Comcode 108621293 Issue 2 August 2000 Lucent Technologies EPS 4802B Battery Plant Notice: |
Original | ||||