Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LEM DC CURRENT TRANSFORMER Search Results

    LEM DC CURRENT TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    UDS2981R/B
    Rochester Electronics LLC UDS2981 - High Voltage, High Current Source Driver PDF Buy
    UDS2983R/B
    Rochester Electronics LLC UDS2983 - High Voltage, High Current Source Driver PDF Buy
    CLC432A/BPA
    Rochester Electronics LLC CLC432 - AMPLIFIER, CURRENT FEEDBACK - Dual marked (5962-9472502MPA) PDF Buy
    CLC400A/BPA
    Rochester Electronics LLC CLC400 - OP AMP, WIDEBAND, FAST SETTLING, CURRENT FEEDBACK - Dual marked (5962-8997001PA) PDF Buy
    LM1578AH/883
    Rochester Electronics LLC LM1578 - Switching Regulator, Current-mode, 0.75A, 100kHz Switching Freq-Max, MBCY8 - Dual marked (5962-8958602GA) PDF Buy

    LEM DC CURRENT TRANSFORMER Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    PR230ACV

    Abstract: PR230 lem current BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 LEM current transformer
    Contextual Info: Current Probe Model PR230 ACV The PR230 ACV current probe has been designed for use with oscilloscopes for accurate non intrusive measurement of AC current. Using the latest transformer technology, the PR230 ACV can measure currents from 100mA to 300A over a frequency range of 40Hz to


    Original
    pr230100ma40khz100pf+6bsen61010-1bsen61010-2-032bsen61010-2-031pr230acvlem currentlem current transformer PDF

    PR201ACI

    Abstract: BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 PR 200 current probe
    Contextual Info: Current Probe Model PR 201ACI The PR 201ACI current probe has been designed for use with multimeters, recorders, power analysers, safety testers etc. for accurate non intrusive measurement of AC current. Using the latest transformer technology, the PR 201ACI


    Original
    201aci10khzbsen61010-1bsen61010-2-032+3bsen61010-2-031pr201acipr 200 current probe PDF

    PR201ACV

    Abstract: BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 PR 200 current probe
    Contextual Info: Current Probe Model PR 201ACV The PR 201ACV current probe has been designed for use with multimeters, recorders, power analysers, safety testers etc. for accurate non intrusive measurement of AC current. Using the latest transformer technology, the PR 201ACV can measure currents


    Original
    201acv10khz100pfbsen61010-1+4bsen61010-2-032bsen61010-2-031pr201acvpr 200 current probe PDF

    Contextual Info: DKS 100 C Current Operated Switches IPN = 4 . 100 A Combine a current transformer, signal conditioner and limit alarm into a single package. The DKS series has an extended current input range, universal solid-state outputs and a wide frequency response. Electrical data


    Original
    PDF

    Contextual Info: Current Transducer HLSR-SM series IPN = 10 . 50 A Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit.


    Original
    10-sm16-sm20-sm32-sm+440-sm50-smane12050424march2014/version PDF

    Contextual Info: Current Transducer HLSR-P series IPN = 10 . 50 A Ref: HLSR 10-P, HLSR 16-P, HLSR 20-P, HLSR 32-P, HLSR 40-P, HLSR 50-P For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features


    Original
    ane12050416december2013/version PDF

    HO 60-NP

    Contextual Info: Current Transducer HO-NSM-0000 SERIES IPN = 8, 15, 25 A Ref: HO 8-NSM-0000, HO 15-NSM-0000, HO 25-NSM-0000 For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Applications


    Original
    ho-nsm-00008-nsm-000015-nsm-000025-nsm-0000+218february2014/versionho 60-np PDF

    HO 60-NP

    Contextual Info: Current Transducer HO-NP-0000 SERIES IPN = 8, 15, 25 A Ref: HO 8-NP-0000, HO 15-NP-0000, HO 25-NP-0000 For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Applications


    Original
    ho-np-00008-np-000015-np-000025-np-0000+218february2014/versionho 60-np PDF

    Contextual Info: Current Transducer HLSR-SM series IPN = 10 . 50 A Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit.


    Original
    10-sm16-sm20-sm32-sm+440-sm50-smane12050416december2013/version PDF

    Contextual Info: SENTINEL 3+ Battery Monitoring Transducer for Impedance, Voltage and Temperature measurements The Sentinel 3+ is a state of the art, System on Chip SoC digital transducer designed to monitor VRLA, gel or looded stationary battery systems. Data is transmitted over a dedicated


    Original
    PDF

    Contextual Info: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer


    Original
    28january2014/version PDF

    Contextual Info: IPN = 500 A Current transducer LF 510-S For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Standards ●● Bipolar and insulated current measurement up to 0.8 kA ●● EN 50178: 1997


    Original
    510-s4may2015/version PDF

    Contextual Info: Current Transducer CTSR series IPRN = 300, 600 mA Ref: CTSR 0.3-P, CTSR 0.6-P For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer


    Original
    94-v03november2011/version PDF

    ctsr series

    Contextual Info: Current Transducer CTSR series IPRN = 300, 600 mA Ref: CTSR 0.3-P, CTSR 0.6-P For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer


    Original
    28january2014/versionctsr series PDF

    cksr series

    Contextual Info: Current Transducer CKSR series IPN = 6, 15, 25, 50 A Ref: CKSR 6-NP, CKSR 15-NP, CKSR 25-NP, CKSR 50-NP For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Applications


    Original
    15-np25-np50-np22march+22013/versioncksr series PDF

    CTSR

    Contextual Info: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Voltage output


    Original
    94-v04november2011/versionctsr PDF

    Contextual Info: Current Transducer CTSR 0.3-TP/SP4 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Voltage output


    Original
    94-v04november2011/version PDF

    Lem LT 300 - t

    Contextual Info: Current transducer IPN = 4000 A Ref: ITC 4000-S For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Features Applications Bipolar and isolated current measurement up to 6 kA Energy metering


    Original
    4000-s21november2011/versionlem lt 300 - t PDF

    LTSR 6-NP

    Abstract: LTSR 25-NP ch-1228 nanalem lem lt 100 p LTS 25-NP hall current transducer lts 6-np LEM hall effect sensor voltage offset cancellation LTSR 15-NP LA 25-NP
    Contextual Info: Technical Information LTSR: ASIC Based Closed-Loop Transducers from 6 A up to 25 A nominal with reference access LTSR: ASIC Based Closed-Loop Transducers from 6 A up to 25 A nominal with reference access. By Stéphane Rollier, Christophe Benz & Hans Dieter Huber.


    Original
    25-npc4-0021roc-10483ch-1228+9ltsr 6-npltsr 25-npnanalemlem lt 100 plts 25-nphall current transducer lts 6-nplem hall effect sensor voltage offset cancellationltsr 15-npla 25-np PDF

    CTSR 0.3-P

    Contextual Info: Current Transducer CTSR 0.3-P/SP1 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Residual current measurement


    Original
    94-v03november2011/versionctsr 0.3-p PDF

    single phase half bridge inverter

    Abstract: IGBT gate drive board fire sensor LM35 single phase IGBT based PWM inverters LEM sensor CURRENT single phase igbt based inverter 200 amps circuit board 5045-04A single phase igbt based inverter 200 amps circuit lem HA Lm35 with application note
    Contextual Info: APPLIED POWER SYSTEMS, INC. BAP1551 Gate Drive Board BAP1551 Gate Drive Board Application Note and Datasheet for Half Bridge Inverters Patent Pending Introduction The BAP1551 Insulated Gate Bipolar Transistor IGBT Gate Drive Board (GDB) discussed in this Datasheet/Applications Note provides a safe, reliable, isolated interface between control


    Original
    bap1551lm-35single phase half bridge inverterigbt gate drive board+8fire sensor lm35single phase igbt based pwm inverterslem sensor currentsingle phase igbt based inverter 200 amps circuit board5045-04asingle phase igbt based inverter 200 amps circuitlem halm35 with application note PDF

    Contextual Info: APPLIED POWER SYSTEMS, INC. BAP1551 Gate Drive Board BAP1551 Gate Drive Board Application Note and Datasheet for Half Bridge Inverters Figure 1: BAP1551 IGBT Gate Driver Board Patent Pending Introduction The BAP1551 Insulated Gate Bipolar Transistor IGBT Gate Drive Board (GDB)


    Original
    bap1551lm-35 PDF

    LTS 6-NP

    Abstract: LTS 15-NP CAS 6-NP LTSR 15-NP LTSR 6-NP ch-1228 cksr6-np LTSR 25-NP CASR50-NP 743 LEM
    Contextual Info: Technical Information CAS / CASR / CKSR series Current Transducers Insulated Highly Accurate Measurements from 1.5 to 50 ARMS CAS / CASR / CKSR series Current Transducers Future precision. Future performances. Now available. CAS / CASR / CKSR series Current Transducers


    Original
    rs-159ch-1228lts 6-nplts 15-np+7cas 6-npltsr 15-npltsr 6-npcksr6-npltsr 25-npcasr50-np743 lem PDF

    transformerless power inverter

    Abstract: leakage current transducer AC lem ct 02-p CT 0.4-TP LEM
    Contextual Info: Current Transducers CT 0.1 . 0.4-P For the electronic measurement of small currents: AC,DC, mixed, with a galvanic isolation between the primary circuit and the secondary circuit. IPN = ± 100.400 mA VOUT = ± 5 V Electrical data Primary nominal current rms


    Original
    500hztransformerless power inverterleakage current transducer aclem ct 02-p+1ct 0.4-tp lem PDF