LEM CURRENT TRANSFORMER Search Results
LEM CURRENT TRANSFORMER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCK111G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 1.1 to 5.5 V, 3.0 A, Inrush current reducing / Reverse current blocking, WCSP6C | Datasheet | ||
| TCK301G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK304G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK305G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK321G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C | Datasheet |
LEM CURRENT TRANSFORMER Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
|
Contextual Info: Current Mode PWM Control Circuit with 50%Max Duty Cycle Features Description The CS-3844B p ro v id es all th e neces sary featu res to im p lem en t off-line fixed frequency c u rren t-m o d e control w ith a m in im u m n u m b e r of external com ponents |
OCR Scan |
cs-3844b600pacs-3844bn8cs-3844bd8+3 | |
|
Contextual Info: AC Current transformer TT 100-SD IPN = 100 A Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). Electrical data IPN IOUT VSZ ÎP |
Original |
100-sdperfo150tt100-sd100ohm+3 | |
LEM current transformerContextual Info: AC Current transformer TT 100-SD IPN = 100 A Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). Electrical data Primary nominal current rms |
Original |
100-sdperfo40tt100-sd100ohm+4 | |
ELECTRICAL CALCULATION FOR TRANSFORMER
Abstract: 5LEM LEM split core transducer
|
Original |
50-sd25ohm50ohm100ohm+5 | |
50-SD
Abstract: LEM current transformer
|
Original |
50-sd25ohm50ohm100ohm+3 | |
LEM current transformerContextual Info: AC Current transformer TT 100-SD IPN = 100 A Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). Electrical data IPN IOUT VSZ ÎP |
Original |
100-sd94-v0tt100-sd100ohm+4 | |
PR230ACV
Abstract: PR230 lem current BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 LEM current transformer
|
Original |
pr230100ma40khz100pf+6 | |
PR201ACI
Abstract: BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 PR 200 current probe
|
Original |
201aci10khzbsen61010-1bsen61010-2-032+3 | |
PR201ACV
Abstract: BSEN61010-1 BSEN61010-2-031 BSEN61010-2-032 PR 200 current probe
|
Original |
201acv10khz100pfbsen61010-1+4 | |
|
Contextual Info: DKS 100 C Current Operated Switches IPN = 4 . 100 A Combine a current transformer, signal conditioner and limit alarm into a single package. The DKS series has an extended current input range, universal solid-state outputs and a wide frequency response. Electrical data |
Original |
||
HO 60-NPContextual Info: Current Transducer HO-NSM-0000 SERIES IPN = 8, 15, 25 A Ref: HO 8-NSM-0000, HO 15-NSM-0000, HO 25-NSM-0000 For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Applications |
Original |
ho-nsm-00008-nsm-000015-nsm-000025-nsm-0000+2 | |
|
Contextual Info: Current Transducer HLSR-SM series IPN = 10 . 50 A Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. |
Original |
10-sm16-sm20-sm32-sm+4 | |
|
Contextual Info: Current Transducer HLSR-P series IPN = 10 . 50 A Ref: HLSR 10-P, HLSR 16-P, HLSR 20-P, HLSR 32-P, HLSR 40-P, HLSR 50-P For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features |
Original |
ane12050416december2013/version | |
|
Contextual Info: SENTINEL 3+ Battery Monitoring Transducer for Impedance, Voltage and Temperature measurements The Sentinel 3+ is a state of the art, System on Chip SoC digital transducer designed to monitor VRLA, gel or looded stationary battery systems. Data is transmitted over a dedicated |
Original |
||
|
|
|||
|
Contextual Info: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer |
Original |
28january2014/version | |
|
Contextual Info: IPN = 500 A Current transducer LF 510-S For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Standards ●● Bipolar and insulated current measurement up to 0.8 kA ●● EN 50178: 1997 |
Original |
510-s4may2015/version | |
|
Contextual Info: Current Transducer CTSR series IPRN = 300, 600 mA Ref: CTSR 0.3-P, CTSR 0.6-P For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer |
Original |
94-v03november2011/version | |
ctsr seriesContextual Info: Current Transducer CTSR series IPRN = 300, 600 mA Ref: CTSR 0.3-P, CTSR 0.6-P For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer |
Original |
28january2014/versionctsr series | |
Lem LT 300 - tContextual Info: Current transducer IPN = 4000 A Ref: ITC 4000-S For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Features Applications Bipolar and isolated current measurement up to 6 kA Energy metering |
Original |
4000-s21november2011/versionlem lt 300 - t | |
|
Contextual Info: Current Transducer CTSR 0.3-TP/SP4 IPRN = 300 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary circuit and the secondary circuit. Features Applications ●● Closed loop compensated current transducer |
Original |
28january2014/version | |
|
Contextual Info: Current Transducer HLSR-SM series IPN = 10 . 50 A Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. |
Original |
10-sm16-sm20-sm32-sm+4 | |
cksr seriesContextual Info: Current Transducer CKSR series IPN = 6, 15, 25, 50 A Ref: CKSR 6-NP, CKSR 15-NP, CKSR 25-NP, CKSR 50-NP For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Applications |
Original |
15-np25-np50-np22march+2 | |
LTS 6-NP
Abstract: LTS 15-NP CAS 6-NP LTSR 15-NP LTSR 6-NP ch-1228 cksr6-np LTSR 25-NP CASR50-NP 743 LEM
|
Original |
rs-159ch-1228lts 6-nplts 15-np+7 | |
CTSRContextual Info: Current Transducer CTSR 0.6-TP/SP2 IPRN = 600 mA For the electronic measurement of current: DC, AC, pulsed., with galvanic isolation between the primary and the secondary circuit. Applications Features Closed loop compensated current transducer Voltage output |
Original |
94-v04november2011/versionctsr | |