Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LDF4RN50A Search Results

    LDF4RN50A Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    HJ7RN-50A

    Abstract: LDF5RN-50A HJ5RN-50 Andrew fsj4rn-50b UL-910 FSJ175 HJ5RP-50 fsj1 ldf4.5-50 EFX2RN-50
    Contextual Info: Ü-aaJLtal Calilas Coaxial Cable Selection Guide KIELIAT H ELIA X Coaxial Cable Selection Guide - 50 -ohm , Foam Dielectric Superflexible, F S J Series Extraflexible, Foam Dielectric, EFX Series VXL Series Nominal Size 1/4" 3/8" 1/2" 3/8" 7/8" Catalog Pages


    OCR Scan
    ul1581ul1666fsj1p-50a-cfsj2p-50-c+11fsj4p-50b-hj7rn-50aldf5rn-50ahj5rn-50andrew fsj4rn-50bul-910fsj175hj5rp-50fsj1ldf4.5-50efx2rn-50 PDF

    Contextual Info: TECHNICAL DATA SHEET 1/4 R164.091.000 STRAIGHT PLUG EZ-FIT Series : QN CABLE 1/2" FLEXIBLE CORRUGATED All dimensions are in mm. . po . ao COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS - MATERIALS BRASS BERYLLIUM COPPER BERYLLIUM COPPER


    Original
    PDF

    L44PCW

    Abstract: MIL-STD-202 METHOD 101 MIL-STD-202 METHOD 213 Andrew L44PCW connector mil-std-202, method 107 27591-109 LDF4RN-50A-S3 mil-std-202 METHOD 106 mil-std-202, method 204,cONDITION A mil-std-202, method 204
    Contextual Info: HELIAX Connector P R O D U C T S P E C I F I C A T I O N L44PCW SC for 243226, LDF4-50A, Special print Cable CHARACTERISTICS Components O-Ring O-Ring Spring Retaining Ring Insulator Inner Contact Silicone Rubber Silicone Rubber Phosphor Bronze PTFE Brass


    Original
    l44pcwldf4-50amil-std-202mil-std-202 method 101+8mil-std-202 method 213andrew l44pcw connectormil-std-202, method 10727591-109ldf4rn-50a-s3mil-std-202 method 106mil-std-202, method 204,condition amil-std-202, method 204 PDF

    Andrew Rxl5-1RNT

    Abstract: Andrew RADIAx Andrew Rxl4 RXL5 - 1RNT RXL4 - 1RNT RXL4 RXL4-2RNT Andrew RXL2-2RNT RXL6 LDF4RN-50A
    Contextual Info: HELIAX Coaxial Cables Fire Retardant Cables and Waveguides Fire R etardance Requirem ents Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC ’ sets the standard for coaxial cable used within buildings and


    OCR Scan
    andrew rxl5-1rntandrew radiaxandrew rxl4rxl5 - 1rnt+6rxl4 - 1rntrxl4rxl4-2rntandrew rxl2-2rntrxl6ldf4rn-50a PDF

    LDF4P-50A-3

    Abstract: ldf4-50a coax LDF4P-50A-8 DIN connector LDF450A LDF4P-50A-42 LDF4P-50A-9 ldf4 L4PN SGL4-06B1
    Contextual Info: 1/2" Foam Dielectric, LDF Series - 50-ohm LDF4-50A D e s c r ip t io n Type N o . Cable Ordering Information Standard Cable 1/2" Standard Cable, Standard Jacket LDF4-50A Fire Retardant Cables 1/2" Fire Retardant Jacket CATVX 1/2" Fire Retardant Jacket (CATVR)


    OCR Scan
    50-ohmldf4-50adb/10041475-5a+1504679a-504679a-704679a8939a-68939a-8ldf4p-50a-3ldf4-50a coaxldf4p-50a-8din connectorldf450aldf4p-50a-42ldf4p-50a-9ldf4l4pnsgl4-06b1 PDF

    LDF4RN-50A

    Contextual Info: TECHNICAL DATA Page STRAIGHT SQUARE FLANGE JACK CLAMP TYPE CABLE 1/2' FLEXIBLE CORRUGATED 4holes DIA 0.13 1 I 2 R161.291.150 N 8 E R IE 8 0.827/2flats -DIA 0.945 024 (PERÇAGE PANNËÂiT) DIA 0.669 (.MOUNTING HOLÊ) (017) A DIA B DIA 4 holes square 0.719-»(□ 18.25)


    OCR Scan
    827/2flatsldf4rn-50a-1/2ldf4rn-50a PDF

    R16109100

    Abstract: R161.091.000 0220G01
    Contextual Info: TECH N ICAL DATA Page R161 .091.000 STRAIGHT PLUG CLAMP TYPE GABLE 1/2' FLEXIBLE CORRUGATED N 8ERIE 8 0. 837/2flats 21/2plats □IA 0.827 ( 1 I 2 021 ) □IA 0.945 (024) 50 NOMINAL IMPEDANCE 0-11 FREQUENCY RANGE CABLES :LDF4RN-50A-1/2* GHz -55/+155 *c TEMPERATURE RATING


    OCR Scan
    837/2flats21/2platsldf4rn-50a-1/2r16109100+2r161.091.0000220g01 PDF

    ldf4-50

    Abstract: R164 R282 ldf4 cable LDF4-50-A
    Contextual Info: TECHNICAL DATA SHEET 1 /3 R164.091.000 STRAIGHT PLUG EZ-FIT CABLE 1/2" FLEXIBLE CORRUGATED Series : QN All dimensions are in mm. COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS “ MATERIALS BRASS BERYLLIUM COPPER BERYLLIUM COPPER


    OCR Scan
    09l000ldf4-50r164r282+2ldf4 cableldf4-50-a PDF

    FLC12-50J

    Abstract: bt 824 Andrew ldf4 LDF4-50A ldf4 cable RFU-520-H1 LDF4-50-A 7610 Diode PT 520
    Contextual Info: RFU-520-H1 REV - DESCRIPTION ENGINEERING RELEASE 1 3 5 6 .878 22.30 5/8-24 UNEF-2A DATE APPR 11/20/08 JDM .610 15.50 1.378 35 1.988 50.50 C.020 .197 5 1.252 31.80 RECOMMENDED STRIPPING DIMENSIONS SPECIFICATIONS: NOTE: SILICONE LUBRICATOR INCLUDED NOT SHOWN


    Original
    rfu-520-h1ldf4-50aldf4rn-50aflc12-50j+11023-10x-002-lr023-10x-001-lr010-06x-001-tx6f-001-btbt 824andrewldf4ldf4 cableldf4-50-a7610diode pt 520 PDF

    ldf4

    Abstract: LDF4RN-50A R282 800 000 n type plugs IP68 R282 LDF4-50-A ldf4 cable LDF45 LDF4RN50A
    Contextual Info: TECHNICAL DATA SHEET 1/4 R161.091.020 STRAIGHT PLUG EZ FIT TYPE Series : N 1/2" CORRUGATED CABLE All dimensions are in mm. . po . ao COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS - MATERIALS BRASS BERYLLIUM COPPER BRASS PTFE SILICONE RUBBER


    Original
    ldf4ldf4rn-50ar282 800 000n type plugs ip68+5r282ldf4-50-aldf4 cableldf45ldf4rn50a PDF

    VP2A-130

    Abstract: pl1537 3AX6 2261A EBLOK-00005 VHP2-220A 143DET RxL4-1rn FPA5250D24-N VHP2-180B
    Contextual Info: N u m erical Index Type Number Page 100845-11 .211 10


    OCR Scan
    xh-1-711xh-4a-101xh-4a-102xh-4a-11+12xh-4a-701-4a-702vp2a-130pl15373ax62261aeblok-00005vhp2-220a143detrxl4-1rnfpa5250d24-nvhp2-180b PDF

    LDF4-RN-50A

    Abstract: DIN 2248
    Contextual Info: HELIAX Connector P R O D U C T S P E C I F I C A T I O N L4PDM 7/16 DIN for LDF4RN-50A, Low Density Foam Dielectric Cable CHARACTERISTICS Components Insulator Clamp Nut PTFE Brass Trimetal Plate Inner Contact Brass Silver Plate Coupling Nut Brass Trimetal Plate


    Original
    ldf4rn-50amil-c-39012cldf4-rn-50adin 2248 PDF

    LDF450A

    Contextual Info: TECHNICAL DATA SHEET 1/4 R164.230.000 STRAIGHT JACK EZ-FIT TYPE Series : QN CABLE 1/2" FLEXIBLE CORRUGATED All dimensions are in mm. . po . ao COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS - MATERIALS BRASS BERYLLIUM COPPER PTFE


    Original
    ldf450a PDF

    RXL7 connector

    Abstract: RXL4 - 1RNT RXL6 Andrew Rxl6 CONNECTOR RxL4-1rn RXL4-2RNT LDF5RN-50A VXL5RN-50 Andrew RADIAX RXL-4 EFX2RN-50
    Contextual Info: Fire Retardant Cables and Waveguides Fire Retardance Requirements Cable and waveguide installed inside a building usually must meet fire retardance requirements. In the United States, the National Electrical Code NEC 1 sets the stan­ dard for coaxial cable used within buildings and normally


    OCR Scan
    rxl7 connectorrxl4 - 1rntrxl6andrew rxl6 connector+6rxl4-1rnrxl4-2rntldf5rn-50avxl5rn-50andrew radiax rxl-4efx2rn-50 PDF

    WIRING diagram USB to rca CABLE

    Abstract: RFU-531 ldf4-50a belden nokia 1280 circuit diagram free L1PNM-H taiko relay Intercomp 1-4082x RFB-1135-T radiall 617 320 Solitron product catalog
    Contextual Info: RF Connectors Division of of RF RF Industries Industries AA Division 1-800-233-1728 CD Available on 7610 Miramar Road, San Diego, CA 92126-4202 • 858 549-6340 • (800) 233-1728 Fax (858) 549-6345 • email: rfi@rfindustries.com • website: rfindustries.com


    Original
    rfa-4024rfa-4010rfa-4005rfa-4081+16rfa-4021rfa-4011rfa-4015rfa-4027rfa-4040rfa-4023-01wiring diagram usb to rca cablerfu-531ldf4-50a beldennokia 1280 circuit diagram freel1pnm-htaiko relayintercomp 1-4082xrfb-1135-tradiall 617 320solitron product catalog PDF

    RFU-502-H1

    Abstract: FLC12-50J LDF4-50A ldf4 LDF4-50-A LDF4RN-50A ldf4 cable 7610 Andrew
    Contextual Info: RFU-502-H1 REV - 3 1 7 6 DATE APPR 12/08/08 JDM 8 .878 2 DESCRIPTION ENGINEERING RELEASE 1.378 1.547 2.283 .197 1.252 RECOMMENDED STRIPPING DIMENSIONS SPECIFICATIONS: IMPEDANCE: NON CONSTANT FREQUENCY RANGE: 0-300 MHz WORKING VOLTAGE: 500 V rms Max. @ Sea Lev


    Original
    rfu-502-h1ldf4-50aldf4rn-50aflc12-50j+11023-10x-002-lr023-10x-001-lr003-06x-001-bt027-06m-001-bt010-06x-002-tx009-06m-011-psldf4ldf4-50-aldf4 cable7610andrew PDF

    Contextual Info: TECHNICAL DATA SHEET 1/4 R164.091.000 STRAIGHT PLUG EZ-FIT Series : QN CABLE 1/2" FLEXIBLE CORRUGATED All dimensions are in mm. . pn . ao COMPONENTS BODY CENTER CONTACT OUTER CONTACT INSULATOR GASKET OTHERS PARTS - MATERIALS BRASS BERYLLIUM COPPER BERYLLIUM COPPER


    Original
    PDF

    Andrew L44Aw

    Abstract: Andrew l44aw connector 50a1 tube L44PCW L44PW LDF4P-50A-9 LDF4P-50A-3 L44N L44AW L4PN
    Contextual Info: C able O rd erin g In fo rm a tio n A tte n u a tio n a n d A verage P o w er Description T ype No. I Standard Cable LDF4-50A 1/2" Standard Cable, Standard Jacket Fire Retardant Cables 1/2“ Fire Retardant Jacket CATVX 1/2" Fire Retardant Jacket (CATVR)


    OCR Scan
    il-c-28830/33211a1768a242774-m+15hbsh-456hbeh-456ct-k350vct8-10vct8-50andrew l44awandrew l44aw connector50a1 tubel44pcwl44pwldf4p-50a-9ldf4p-50a-3l44nl44awl4pn PDF

    Contextual Info: Product Specifications LDF4RN-50A-800KT LDF4­50A Jumper, 243.84 m CHARACTERISTICS General Specifications Cable Family LDF4­50A Interface, Connector A Sold separately Interface, Connector B Sold separately Length 243.840 m | 800.000 ft


    Original
    ldf4rn-50a-800ktldf450a-50a-800kt PDF