Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LDC15D Search Results

    SF Impression Pixel

    LDC15D Price and Stock

    Murata Manufacturing Co Ltd
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bristol Electronics LDC15D190A0010A 4,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    Murata Manufacturing Co Ltd LDC15D190A0007AH-078

    DIRECTIONAL COUPLER, 880MHZ MIN, 1785MHZ MAX, 0.38DB INSERTION LOSS-MAX (Also Known As: LDC15D190A0007)
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Quest Components () LDC15D190A0007AH-078 3,990
    • 1 $0.75
    • 10 $0.75
    • 100 $0.75
    • 1000 $0.31
    • 10000 $0.28
    Buy Now
    LDC15D190A0007AH-078 3,990
    • 1 $0.75
    • 10 $0.75
    • 100 $0.75
    • 1000 $0.31
    • 10000 $0.28
    Buy Now

    Murata Manufacturing Co Ltd LDC15D190A0013A

    DIRECTIONAL COUPLER, 880MHZ MIN, 1785MHZ MAX, 0.38DB INSERTION LOSS-MAX
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Quest Components LDC15D190A0013A 3,307
    • 1 $0.75
    • 10 $0.75
    • 100 $0.75
    • 1000 $0.31
    • 10000 $0.28
    Buy Now

    Documents mentioning LDC15D

    Document Partial File Text Tags Type PDF
    ad8314
    a 100 MHz–2500 MHz 45 dB RF Detector/Controller AD8314 For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This high-pass coupling, with a corner at 16 MHz, determines the lowest operating frequency. Thus, the source may be dc-grounded.
    Original PDF
    ad8314
    100 MHz to 2.7 GHz, 45 dB RF Detector/Controller AD8314 For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This highpass coupling, with a corner at approximately 16 MHz, determines the lowest operating frequency. Therefore, the
    Original PDF
    ad8316
    Dual Output GSM PA Controller AD8316 power control signal is required for each band. The logarithmic amplifier technique provides a much wider measurement range and better accuracy than is possible using controllers based on diode detectors. In particular, multiband and multimode cellular designs can benefit from the temperature-stable (–30°C to
    Original PDF
    da9142
    DA9142.003 28 January, 2004 MAS9142 Power Amplifier Controller (PAC) and 2.8 V, 50 mA LDO Voltage Regulator • Temperature Compensation of Sensor Signal • Bias Current Source for Detector Diodes • Applicable for a Wide Range of Power Amplifiers • Low Noise LDO Regulator Included
    Original PDF
    50 dB GSM PA Controller AD8311 Its high
    50 dB GSM PA Controller AD8311 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. For convenience, the signal is internally ac-coupled. This high-pass coupling, with a corner at approximately
    Original PDF
    MULTILAYER DEVICES DIRECTIONAL COUPLERS, CHIP
    MULTILAYER DEVICES DIRECTIONAL COUPLERS, CHIP MULTILAYER LDC Series FEATURES ■ Small size: see dimensions Light weight Tape and reel packaging Reflow solderable Available to cover a frequency range from 200MHz to 2.5GHz ■ Coupling values 10dB, 14dB and others
    Original PDF
    lmv243
    211026_App. Brief #122_4.qxd 12/18/02 3:18 PM Page 1 A Multi-Band GSM/GPRS Power Amplifier Controller Application Brief 122 Barry Yuen As shown in Figure 1, the LMV243 consists of a 45 dB log amp detector for sensing the RF output power level of a PA and an error amplifier to close
    Original PDF
    ad8311
    50 dB GSM PA Controller AD8311 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. For convenience, the signal is internally ac-coupled. This high-pass coupling, with a corner at approximately
    Original PDF
    ad8314
    a 100 MHz–2.7 GHz 45 dB RF Detector/Controller AD8314* For convenience, the signal is internally ac-coupled, using a 5 pF capacitor to a load of 3 kΩ in shunt with 2 pF. This high-pass coupling, with a corner at approximately 16 MHz, determines the lowest operating frequency. Thus, the source may be dc-grounded.
    Original PDF
    ad8316
    Dual Output GSM PA Controller AD8316 power control signal is required for each band. The logarithmic amplifier technique provides a much wider measurement range and better accuracy than is possible using controllers based on diode detectors. In particular, multiband and multimode cellular designs can benefit from the temperature-stable (–30°C to
    Original PDF
    directional coupler
    MULTILAYER DEVICES DIRECTIONAL COUPLERS, CHIP MULTILAYER LDC Series FEATURES ■ Small size: see dimensions Light weight Tape and reel packaging Reflow solderable Available to cover a frequency range from 200MHz to 2.5GHz ■ Coupling values 10dB, 14dB and others
    Original PDF
    a 50 dB GSM PA Controller AD8315 FEATURES
    a 50 dB GSM PA Controller AD8315 FEATURES Complete RF Detector/Controller Function >50 dB Range at 0.9 GHz (–49 dBm to +2 dBm re 50 ⍀) Accurate Scaling from 0.1 GHz to 2.5 GHz Temperature-Stable Linear-in-dB Response Log Slope of 23 mV/dB, Intercept at –60 dBm at 0.9 GHz
    Original PDF
    ad8315
    50 dB GSM PA Controller AD8315 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. FEATURES Complete RF detector/controller function >50 dB range at 0.9 GHz (−49 dBm to +2 dBm, re 50 Ω)
    Original PDF
    ad8315
    50 dB GSM PA Controller AD8315 FEATURES Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. Complete RF detector/controller function >50 dB range at 0.9 GHz (−49 dBm to +2 dBm, re 50 Ω)
    Original PDF
    ad8311
    50 dB GSM PA Controller AD8311 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. For convenience, the signal is internally ac-coupled. This high-pass coupling, with a corner at approximately
    Original PDF
    ad8316
    Dual Output GSM PA Controller AD8316 power control signal is required for each band. The logarithmic amplifier technique provides a much wider measurement range and better accuracy than is possible using controllers based on diode detectors. In particular, multiband and multimode cellular designs can benefit from the temperature-stable (–30°C to
    Original PDF
    da9142
    DA9142.002 4 January, 2002 MAS9142 Power Amplifier Controller (PAC) and 2.8 V, 50 mA LDO Voltage Regulator • Temperature Compensation of Sensor Signal • Bias Current Source for Detector Diodes • Applicable for a Wide Range of Power Amplifiers • Low Noise LDO Regulator Included
    Original PDF
    ad8315
    50 dB GSM PA Controller AD8315 Its high sensitivity allows control at low signal levels, thus reducing the amount of power that needs to be coupled to the detector. FEATURES Complete RF Detector/Controller Function >50 dB Range at 0.9 GHz (–49 dBm to +2 dBm re 50 ⍀)
    Original PDF