LC1 D3 Search Results
LC1 D3 Datasheets (4)
Select Manufacturer
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| LC1-D32 | Schneider Electric | TeSys contactors | Original | 115.88KB | 12 | ||
| LC1-D32 | Telemecanique | Contactors and protection relays | Original | 22.07KB | 1 | ||
| LC1-D32 | Telemecanique | Contactors and Protection Relays | Scan | 558.17KB | 6 | ||
| LC1-D38 | Schneider Electric | TeSys contactors | Original | 115.88KB | 12 |
LC1 D3 Price and Stock
Schneider Electric
Schneider Electric LC1D32BDContactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 24VDC; 32A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D32BD | 68 | 1 |
|
Buy Now | ||||||
|
LC1D32BD | 116 |
|
Buy Now | |||||||
Schneider Electric LC1D38BDContactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 24VDC; 38A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D38BD | 39 | 1 |
|
Buy Now | ||||||
|
LC1D38BD | 6 |
|
Buy Now | |||||||
|
LC1D38BD | Bulk | 18 | 1 |
|
Buy Now | |||||
Schneider Electric LC1D32EDContactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 48VDC; 32A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D32ED | 36 | 1 |
|
Buy Now | ||||||
Schneider Electric LC1D32MDContactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 220VDC; 32A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D32MD | 30 | 1 |
|
Buy Now | ||||||
Schneider Electric LC1D32G7Contactor: 3-pole; NO x3; Auxiliary contacts: NO + NC; 120VAC; 32A |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
LC1D32G7 | 20 | 1 |
|
Buy Now | ||||||
|
LC1D32G7 | 3 |
|
Buy Now | |||||||
|
LC1D32G7 | 3 |
|
Buy Now | |||||||
Documents mentioning LC1 D3
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| LA 9-D 09 978 Kit condamnation MECHANICAL | LA 9-D 09 978 Kit condamnation MECHANICAL INTERLOCK KIT VERRIEGELUNG MECHANISCH FÜR WENDESCHÜTZE KIT D’INTERBLOCCO KIT CONDENACION KIT DE ENCRAVAMENTO MECÁNICO W9 0378144 01 32 p«Te»em ecanique D09 % D12 D18 ---- O , ---- ---- D25 D32 — LC1 LP1 LC1 LP1 LC1 LP1 LC1 LP1 LC1 LP1 |
OCR Scan | ||||
| tesys | 24531 Page 94 Thursday, October 25, 2001 6:02 PM Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 |
Original | ||||
| tesys contactors | References TeSys contactors a.c. coils for 3-pole contactors LC1-D Control circuit voltage Uc V Average resistance at 20 °C ± 10 % Ω Inductance of closed circuit H Reference (1) Weight kg For 3-pole " contactors LC1-D09…D38 and LC1-DT20…DT60 Specifications |
Original | ||||
| lc1-d09 | Dimensions TeSys contactors Model d contactors Control circuit: a.c. LC1-D09…D18 (3-pole) LC1-D25…D38 (3-pole) LC1-DT20…DT60 (4-pole) 44 Minimum electrical clearance 44 Minimum electrical clearance LA4 b b b1 b1 LA4 D093… D183 99 107 123 (1) 132 (1) |
Original | ||||
| lc1-d115 | Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1, |
Original | ||||
| lc1lc1lc1d09 | Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1, |
Original | ||||
| tesys | 24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) |
Original | ||||
| tesys d contactors | TeSys contactors Characteristics TeSys D contactors Contactor type LC1 D09…D18 DT20 and DT25 D25…D38 DT32 and DT40 D40A…D65A DT60A and DT80A D80…D95 D115 and D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Conforming to IEC 60947-4-1, |
Original | ||||
| Selection 5 TeSys contactors 5 For utilisation | Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC (θ y 60 °C) 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1 |
Original | ||||
| lc1-d | Contactors and protection relays Contactors, types LC1-D Selection guide : pages 1/12 to 1/43 Characteristics : pages 2/56 to 2/69 References : pages 2/70 to 2/77 Schemes : pages 2/92 and 2/93 Dimensions c 12,5 (LA8) c1(LA1) 45 12,5 (LA8) 56 107(3)(DF,DT) |
Original | ||||
| Contactors and protection relays Selection guide | Contactors and protection relays Selection guide pages 1 '12 tu 1/43 References . uages 2/70 to 2''101 Dimensions pages 2/88 to 2*91 2/102 and 2/103 Schemes pages 2/92. 2'93 and 2 /’ 03 Type Contactors, types LC1-D and LP1-D Control circuit: a.c. or d.c. |
OCR Scan | ||||
| la6 dk10 | -127V 110 -DC z AC 60H 50/ E1 E2 LA6 DK10 LA1-DN10, DN01 LA6-DK 2 LA8-DN 2.3 LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor type and rating 2/78 Te Contactors and protection relays |
Original | ||||
| d323 | References 4 Protection components 4 Fuse carriers 500504_1 3-pole basic blocks Rating Cartridge fuse size Number of early break contacts (1) Single-phase protection device (2) Reference (3) – (4) Without LS1 D323 0.270 Weight kg Connection by spring terminals |
Original | ||||
| tesys d contactors | TeSys contactors References TeSys D contactors for motor control up to 75 kW at 400 V, in category AC-3 810356 For connection by screw clamp terminals and lugs 3-pole contactors Standard power ratings of 3-phase motors 50-60 Hz in category AC-3 (θ y 60 °C) |
Original | ||||
|
|
||||||
| TeSys contactors References 537729 Component | TeSys contactors References 537729 Component parts for assembling reversing contactors for motor control, low-speed/high-speed starters and star-delta starters For 3-pole reversing contactors for motor control Contactors with screw clamp terminals or connectors. Horizontally mounted, assembled by customer |
Original | ||||
| Sélection Contactors Contactors for the North | Sélection Contactors Contactors for the North American market conforming to standards UL and CSA, 20 to 120 A Standard power ratings Taille of motors 50/60 Hz Size Single-phase 3-phase 1Ø 3Ø 115 V 230 V 200 V 230 V 460 V 575 V 240 V 208 V 240 V 480 V 600 V |
Original | ||||
| Soft starters ATS 01 Catalogue May 07 General | Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3 |
Original | ||||
| tc9240f | TO SH IBA TC9240F TO SHIBA CMOS DIGITAL INTEGRATED CIRCUIT SILICON MONOLITHIC TC9240F AUDIO LCD DRIVER IC The TC9240F is a driver 1C designed for exclusive use for output expansion LCD which is controlled by serial data. FEATURES • 1 / 2 or 1 / 3 duty and 1/2 or 1/3 bias can be switched. |
OCR Scan | ||||
| ラジアルリードインダクタ RADIAL LEADED INDUCTORS OPERATING | ラジアルリードインダクタ RADIAL LEADED INDUCTORS OPERATING TEMP. K25VJ105C(製品自己発熱含む) fIncluding self-generated heatg 特長 FEATURES YThe LHL08~LHL16 series radial inductors are encapsulated in a resin housing which adds to the stability of the mounted part on a printed circuit board. |
Original | ||||
| Issued November 2009 DATA SHEET LR-D OVERLOAD | Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common, |
Original | ||||
| tc9240f | TO SHIBA TC9240F TOSHIBA CMOS DIGITAL INTEGRATED CIRCUIT SILICON MONOLITHIC TC9240F AUDIO LCD DRIVER IC The TC9240F is a driver 1C designed for exclusive use for output expansion LCD which is controlled by serial data. FEATURES • 1 / 2 or 1 / 3 duty and 1/2 or 1/3 bias can be switched. |
OCR Scan | ||||
| altivar 31 | Presentation Variable speed drives for asynchronous motors 2 Altivar 31 ESC ENT stop reset FWO REV 3 2 RUN 4 1 5 6 7 2 Presentation (continued) Variable speed drives for asynchronous motors 2 Altivar 31 Applications The Altivar 31 drive is a frequency inverter for 3-phase squirrel cage asynchronous |
Original | ||||
| sn65512c | SN65512C, SN75512C VACUUM FLUORESCENT DISPLAY DRIVERS SLDS054 – D3516, MAY 1990 • Each Device Drives 12 Lines 60-V Output Voltage Swing Capability 25-mA Output Source Current Capability High-Speed Serially-Shifted Data Input TTL-Compatible Inputs |
Original | ||||
| variable speed drives | Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com |
Original | ||||