Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    LANDIS STAEFA Search Results

    Documents mentioning LANDIS STAEFA

    Document Partial File Text Tags Type PDF
    pfb-t1
    1 836 PFB-T1 Temperature sensor 1713). Siemens Building Technologies Landis & Staefa Division CA1N1836E / 11.1998 1/2 © 1998 Siemens Building Technologies Ltd. CA1N1836E / 11.1998 2/2 Siemens Building Technologies Landis & Staefa Division
    Original PDF
    landis
    1 Siemens Building Technologies Landis & Staefa Division 839 CA1N1839E / 11.1998 1/2 © 1998 Siemens Building Technologies Ltd. CA1N1839E / 11.1998 2/2 Siemens Building Technologies Landis & Staefa Division
    Original PDF
    qbe620-p
    1 904 Pressure sensor for liquid and gaseous media QBE620-P… Pressure sensor for the measurement of positive pressure in HVAC applications. • Piezo-resistive system of measurement • DC 0…10 V output signal • Complete sensor cast in synthetic resin
    Original PDF
    qaa32
    1 747 Room Temperature Sensor QAA32 NTC resistor sensing element Use In HVAC plants to acquire the room temperature. Functions 1747D01 Ω 9000 7000 5000 The sensor acquires the room temperature by means of its NTC resistor. The resistance value changes according to the ambient
    Original PDF
    pressure sensor
    1 921 Differential pressure sensor QBE64-DP4 for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative pressures and pressure differentials in HVAC systems. • Measuring system based on ceramic lever technology
    Original PDF
    qbe61
    1 Differential Pressure Sensor 915 QBE61.2-dp0,5 This sensor delivering an active measuring signal of DC 0…10 V and works on a AC 24 V operating voltage. Measuring ranges between 0 and 0.5 bar differential pressure. Application Sensing of differential pressure in heating, ventilating and air conditioning plants.
    Original PDF
    pressure sensor
    1 920 Differential pressure sensor QBE63-DP… for neutral and mildly corrosive liquids and gases Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and negative pressures and pressure differentials in HVAC systems.
    Original PDF
    air velocity sensor
    1 1932P01 932 Air velocity sensor QVM62.1 Use This sensor is used to control the air velocity to a constant value, or to balance out pressure fluctuations (supply or extract air control), or to monitor the flow in air ducts. It primarily is used for modulating fan control in primary plants to set the basic volume
    Original PDF
    qbe61
    1 1923P01 923 Differential pressure sensors QBE61.3-DP… for neutral or slightly aggressive gases and liquids • Operating voltage AC 24 V or DC 18…33 V Output signal DC 0…10 V Connecting male thread G ½" 3 versions covering a total differential pressure range of 0 … 10 bar
    Original PDF
    qpa84
    1 Indoor Air Quality Controller 571 QPA84 With integrated VOC 1) ) sensor, operating voltage AC 230 V, two-position output (non-potential-free relay contact) 1) VOC = Volatile Organic Compounds Use In ventilation plant to optimize the indoor air quality and the consumption of energy by
    Original PDF
    hygro
    1 Duct Hygrostats 514 QFM81… for relative humidity QFM81.21 QFM81.2 On / off hygrostat with microswitch, with temperature-compensated humidity sensor for temperature-independent humidity measurements, with stabilized sensing strip (good linearity, very stable even at high humidity,
    Original PDF
    qfa81
    1 Room Hygrostats 513 QFA81… for relative humidity QFA81.1 QFA81 On / off hygrostat with microswitch, with humidity sensor, with plastic texture sensing strip (good linearity, wide measuring range), for the control of humidification equipment, for the control of dehumidification equipment,
    Original PDF
    1860p01
    1 1860P01 860 QFM65.1 Duct sensor for relative humidity and temperature Operating voltage AC 24 V Signal output DC 0…10 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement accuracy ± 3 % r. h. within the comfort range
    Original PDF
    qbe61
    1 Pressure Detectors 901 QBE61.1… Active pressure detector delivering a DC 0…10 V measuring signal and operating on AC 24 V. There are five different versions available, with measuring ranges between 0 and 40 bar. Application Measuring and sensing of overpressure in heating, ventilating and air conditioning
    Original PDF
    qaa64
    1 Room Temperature Sensor 722 QAA64 vandalproof though concealed mounting Use Acquisition of room temperature in spaces where the detector needs to be protected against damage or destruction by people. Such spaces are public buildings like schools, administrative buildings, multipurpose halls, etc.
    Original PDF
    fs-t1l2
    1 837 FS-T1L2, FS-T1L5 Probe sensor • T1 sensor element • Universally applicable as immersion, strap-on, wall surface or air temperature sensor • Suitable for retrofit and expansion of existing systems • An advanced forming process is used in the manufacture of the
    Original PDF
    fr-t1k
    1 735 FR-T1K Room temperature sensor Compact room sensor for measurement of the air temperature in conjunction with HVAC systems • T1 measuring element Suitable for wall-mounting Ideal where space is limited Discreet appearance FR-T1K Technical data
    Original PDF
    fk-t1k
    1 775 FK-T1K.. Duct temperature sensor Sensor for measurement of duct air temperature in HVAC systems • T1 measuring element • Sensor probe easy to remove without dismantling sensor housing or disconnecting wiring • Fast response time • Plastic pipe between housing and
    Original PDF
    transducer
    5 Signal transducer (T1) for Ni1000 temperature sensor 142 AQA61.20 Signal transducer allowing the use of Ni1000 sensors for controllers with a T1 sensor input.  Converts an Ni1000 sensor signal into a T1-type output signal  Transducer supply from connected controller
    Original PDF
    1 656 PB-T1 Room temperature sensor Room sensor
    1 656 PB-T1 Room temperature sensor Room sensor for HVAC systems, for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes • Socket for the PRONTO IRC ZS1 service terminal • Trimming potentiometer for
    Original PDF
    clamp-on
    1 804 Clamp-on temperature sensor QAD100.1 Use The sensor is used for acquiring the medium temperature on the surface of pipes (e.g. the heating water in heating, ventilation or air conditioning plants). It is designed for use in connection with automation equipment, display and logging
    Original PDF
    fr-t1
    1 736 FR-T1/A Room temperature sensor Room sensor for HVAC systems for measurement of the air temperature • T1 measuring element • Suitable for wall mounting on all standard flush-mounting boxes FR-T1/A Technical data Application range 0… 50 °C Measuring element
    Original PDF
    duct temperature sensor
    1 Duct temperature sensor 778 FK-TP/200 for HVAC systems Duct temperature sensor for heating, ventilation and air conditioning systems – For use with controllers with Pt100 sensor inputs – In conjunction with MULTIREG and INTEGRAL RS. Use The FK-TP/200 duct temperature sensor can be used in air ducts for heating, ventilation
    Original PDF
    qad26
    1 Clamp-on Temperature Sensor 802 QAD26.220 Use Heating, ventilation, air conditioning and refrigeration plant. Acquisition of the medium temperature in pipes from −35 to +90 °C to provide measurement, limitation, compensation, or control. Ordering and
    Original PDF
    solar sensor
    942 1 FS-T1 Solar Sensor The sensor measures the influence of solar irradiation on the heating of internal rooms. The sensor allows the flow temperature or the supply air temperature to be optimised for different sides of the building in order to reduce energy use and to
    Original PDF