Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    L-BRACKET TO MOUNT Search Results

    L-BRACKET TO MOUNT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    BLM15PX330BH1D
    Murata Manufacturing Co Ltd FB SMD 0402inch 33ohm POWRTRN PDF
    BLM15PX600SH1D
    Murata Manufacturing Co Ltd FB SMD 0402inch 60ohm POWRTRN PDF
    BLM21HE601SN1L
    Murata Manufacturing Co Ltd FB SMD 0805inch 600ohm NONAUTO PDF
    BLM21HE472BH1L
    Murata Manufacturing Co Ltd FB SMD 0805inch 4700ohm POWRTRN PDF
    BLM15PX330SH1D
    Murata Manufacturing Co Ltd FB SMD 0402inch 33ohm POWRTRN PDF

    L-BRACKET TO MOUNT Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    z144

    Abstract: Ohmite RF Z-235 Z-28 Z-460 Z-144
    Contextual Info: L Z-7 has no wire leads • Z-7 type furnished with nonmagnetic mounting bracket. • Z-14, Z-28 type have wire leads welded to lug type terminals. • Z-50, Z-144, Z-235, Z-460 type have axial wire leads. R. F. Plate Chokes Z-7, -14 & -28 D L 4.70 2.60


    Original
    Z-144, Z-235, Z-460 z144 Ohmite RF Z-235 Z-28 Z-144 PDF

    DBMM25PD

    Abstract: DAMM15SD DBMM25SD ddmm50sd DAMM15PD
    Contextual Info: Right A n g l e D D*M How to Order - High-Rel Printed Circuit Mount Connectors Righ t A n gle PC Tail Receptacles, W ith Bracket .120(3.15 T hrough-H oles Only) PC Tails •.030 (0.76) Diameter Number of Contacts (Shell Size) .127 (3.23) ’ .027 (0.69)


    OCR Scan
    DAMM15SD DBMM25SD DBMM25PD DAMM15SD DBMM25SD ddmm50sd DAMM15PD PDF

    transformer 240v

    Abstract: 40VA TCT40-06E07AB
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-06E07AB Description: Triad control transformers come with tamper resistant shrouds for safety and steel bracket welded to the bottom of the transformer for ease of mounting. style comes with ¼ inch Quick Connects.


    Original
    UL1585, TCT40-06E07AB LR67888 22520B transformer 240v 40VA TCT40-06E07AB PDF

    transformer 240v

    Abstract: 40VA TCT40-05E07AB 4 pin transformers
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-05E07AB Description: Triad control transformers come with tamper resistant shrouds for safety and steel bracket welded to the bottom of the transformer for ease of mounting. style comes with ¼ inch Quick Connects.


    Original
    UL1585, TCT40-05E07AB 22520B transformer 240v 40VA TCT40-05E07AB 4 pin transformers PDF

    transformer 240v to 24v

    Abstract: LR67888 transformer bobbin 4 pin 277 fuse construction transformer 240v 40VA TCT40-09E07AB 09E07
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-09E07AB Description: Triad control transformers come with tamper resistant shrouds for safety and steel bracket welded to the bottom of the transformer for ease of mounting. style comes with ¼ inch Quick Connects.


    Original
    UL1585, TCT40-09E07AB LR67888 22520B transformer 240v to 24v LR67888 transformer bobbin 4 pin 277 fuse construction transformer 240v 40VA TCT40-09E07AB 09E07 PDF

    transformer 240v to 24v

    Abstract: transformer 240v 130C 40VA TCT40-02E07AB Triad F-269U
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-02E07AB Description: Triad control transformers come with tamper resistant shrouds for safety and a steel bracket welded to the bottom of the transformer for ease of mounting. This style comes with ¼ inch Quick Connects.


    Original
    UL1585, TCT40-02E07AB 22520B transformer 240v to 24v transformer 240v 130C 40VA TCT40-02E07AB Triad F-269U PDF

    130C

    Abstract: 40VA TCT40-01E07AB
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-01E07AB Description: Triad control transformers come with tamper resistant shrouds for safety and a steel bracket welded to the bottom of the transformer for ease of mounting. This style comes with ¼ inch Quick Connects.


    Original
    UL1585, TCT40-01E07AB 22520B 130C 40VA TCT40-01E07AB PDF

    12V 30A PCB RELAY

    Abstract: 30A14VDC TRV4 12V 40A Relay NC30A
    Contextual Info: T810S-A001C E L E C T R O N I C S 汽 车 继 电 器 TRV4 ● 40A continuous rating 85℃ ● 1A&1C arrangements ● Plug-in or PC board terminals ● Optional mounting bracket ● Conform to RoHS,ELV directive 28x28×25 28×31.8×41 •ORDERING CODE 定购代码


    Original
    T810S-A001C --12V 24VDC 12VDC; 10-40Hz, 000operations/hr 800operations/hr 12V 30A PCB RELAY 30A14VDC TRV4 12V 40A Relay NC30A PDF

    91929

    Abstract: bolts RDS-CL-02
    Contextual Info: CATALOG a Ho n e y we I I D i v i s i o n FED. MFG. CODE RAILWAY BRACKET SINGLE MOUNT L I S T I NG THIS DRAWING HONEYWELL. COVERS THIS A PROPRIETARY DRAWING IS NOT TO ITEM BE AND COPIED IS OR THE PROPERTY USED WITHOUT OF MICRO THE SWITCH. APPROVAL A OF DIVISION


    OCR Scan
    RDS-CL-02 E-33312 119RE, 132RE, 133RE, 136RE, 140RE 91929 bolts RDS-CL-02 PDF

    Contextual Info: AR- 1 0 10-METER RINGO ANTENNA cushcrcrft C O R P O R A T I O N AR-10 A S S E M B L Y Al l steps for assem bling the ring and tuning assem bly to the base section AA are shown in figure 1. M ount one ring section (190) to the bottom side of the lower bracket on the base section. Mount the remaining ring section (190) to the top side of the


    OCR Scan
    10-METER AR-10 PDF

    136re

    Abstract: 119RE 140RE RDS-CL-04 132RE 133RE
    Contextual Info: C A T A L O G <0 <N q> CD <N O L I ST ING T H I S D RAW ING H O N E Y W E L L . a Honeywe II FED. MFG. CODE Division 91929 RAILWAY BRACKET ADJUSTABLE SINGLE MOUNT C OVE R S T H I S A P R O P R I E T A R Y D R AW ING IS NOT TO ITEM BE AND C O P I E D IS OR


    OCR Scan
    RDS-CL-04 E-33323 119RE, 132RE, 133RE, 136RE 140RE 119RE RDS-CL-04 132RE 133RE PDF

    LR67888

    Abstract: transformer 240v to 24v DSA0051365 transformer 240v 40VA TCT40-06E07K 240v output transformer
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-06E07K Description: Triad control transformers come with tamper resistant shrouds for safety and a steel bracket welded to the bottom of the transformer for ease of mounting. This style comes with 18 AWG stranded leads which are 12 inches in length.


    Original
    UL1585, TCT40-06E07K E65390, LR67888 22520B LR67888 transformer 240v to 24v DSA0051365 transformer 240v 40VA TCT40-06E07K 240v output transformer PDF

    TCT40-01E07K

    Abstract: 130C 40VA
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-01E07K Description: Triad control transformers come with tamper resistant shrouds for safety and a steel bracket welded to the bottom of the transformer for ease of mounting. This style comes with 18 AWG stranded leads which are 12 inches in length.


    Original
    UL1585, TCT40-01E07K 22520B TCT40-01E07K 130C 40VA PDF

    40VA

    Abstract: Triad F-269U transformer 240v 130C TCT40-05E07K transformer 240v to 24v
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-05E07K Description: Triad control transformers come with tamper resistant shrouds for safety and a steel bracket welded to the bottom of the transformer for ease of mounting. This style comes with 18 AWG stranded leads which are 12 inches in length.


    Original
    UL1585, TCT40-05E07K 22520B 40VA Triad F-269U transformer 240v 130C TCT40-05E07K transformer 240v to 24v PDF

    UL-1585

    Abstract: 130C 40VA TCT40-02E07K
    Contextual Info: C o n t r o l Tr a n s f o r m e r UL1585, Class 2 TCT40-02E07K Description: Triad control transformers come with tamper resistant shrouds for safety and a steel bracket welded to the bottom of the transformer for ease of mounting. This style comes with 18 AWG stranded leads which are 12 inches in length.


    Original
    UL1585, TCT40-02E07K 22520B UL-1585 130C 40VA TCT40-02E07K PDF

    136re

    Abstract: RDS-CL-08 119RE
    Contextual Info: CATALOG L I S T ING THIS DRAWING HONEYWELL. in a oc I 5> ID o a Honeywe II D i v i s i o n FED. MFG. CODE BRACKET - SUBASSEMBLY COVERS THIS A PROPRIETARY DRAWING IS NOT TO ITEM BE AND COPIED IS OR THE PROPERTY USED WITHOUT OF MICRO THE SWITCH. APPROVAL A OF


    OCR Scan
    C094132 RDS-CL-08 E-33335 119RE, 132RE, 133RE, 136RE 140RE RDS-CL-08 119RE PDF

    Contextual Info: C A T A L O S L IS T IN O MICRO SWITCH mm * mnumB-nottnnu kmutm a am ur rnvMr, luiHOts ¿CM Ss FED. MFR. CODE 9 1 9 2 9 ★ ASSEMBLYPU SH BU T TO N SWITCH IP B 5-T SM CORROSION R ES IS T A N T STEEL P L U N G E R ,B U S H IN G , AND BRACKET .25 R— i I IO


    OCR Scan
    PDF

    136re

    Abstract: RDS-CL-05 E3332
    Contextual Info: CATALOG L I S T ING THIS DRAWING HONEYWELL. co o 00 <0 o a Honeywe II D i v i s i o n FED. MFG. CODE 91929 RAILWAY BRACKET COVERS THIS A PROPRIETARY DRAWING IS NOT TO ITEM BE AND COPIED IS OR THE PROPERTY USED WITHOUT OF MICRO THE SWITCH. APPROVAL A OF D I V IS IO N


    OCR Scan
    RDS-CL-05 E-33325 119RE, 132RE, 133RE. 136RE 140RE SHOC25 RDS-CL-05 E3332 PDF

    10013-G

    Abstract: 68AT11-1 68AT11-5 68AT11-7 TL-10632 TS-10020
    Contextual Info: F O - 5 5 1 1 1 -A HONEYWELL PART NUMBER REV DOCUMENT 16 0012387 .388 ±.OIO 3 4 °± 8 ° 68AT11 S E R IE S C H A R T 1 2 4 0 ± .0 0 3 DIA to ta l tra v e l FA A -P M A APPROVED CORROSION RESISTANT A LEVER , BUSHING AND BRACKET / 4 \ CATALO G K E Y W A Y P O S IT I O N


    OCR Scan
    68AT11 TL-10632 TS-10013 TS-10020 08APR05 68AT11-1 280CT74 5M-1994 10013-G 68AT11-5 68AT11-7 PDF

    SMB18A

    Abstract: SMBAMSQ60P SMBAMS30RA SMBLT32 SMBP-4R SMBQ12S
    Contextual Info: s iouon v e i Pr ect S BRACKETS – ACCESSORIES Sensing Accessories Mounting Brackets page 370 • Using the right bracket ensures optimum performance from your Banner sensors. • Stainless steel and reinforced thermoplastic polyester mounts reduce installation time


    Original
    14-ga. SMB18A SMBAMSQ60P SMBAMS30RA SMBLT32 SMBP-4R SMBQ12S PDF

    Potentiometers center tap 5k

    Abstract: Potentiometer 250K Spectrol potentiometer 357 C-30 Potentiometers center tap SPECTROL 0156-l Potentiometers center tap 50k
    Contextual Info: Model 174, 175, 176 Vishay Spectrol Conductive Plastic Potentiometers FEATURES • • • • • • • • • Model 174, 175, 176 Flat Pack Type Low Mount, Square and Long-Life Rotational Life 50K Cycles, 50K Cycles and 2M Cycles Grid Type 0.100, 0.100/0.200


    Original
    16-May-01 Potentiometers center tap 5k Potentiometer 250K Spectrol potentiometer 357 C-30 Potentiometers center tap SPECTROL 0156-l Potentiometers center tap 50k PDF

    79212

    Abstract: en 50022-35 SF4 relay R0337 ah56 SF4-AH40 SF4-AH20 SF4-AH 74 hc 589 SF4-AH96
    Contextual Info: SF4-AH DIMENSIONS Unit: mm in SF4-AH□ Sensor Assembly dimensions Mounting drawing for the sensor on which the sensor mounting brackets and the intermediate supporting brackets are mounted. <Back mounting> <Side mounting> 30 1.181 28 1.102 26 1.024 16.9 0.665


    Original
    CE-SF4AH-10 79212 en 50022-35 SF4 relay R0337 ah56 SF4-AH40 SF4-AH20 SF4-AH 74 hc 589 SF4-AH96 PDF

    customer manual 409-5128

    Abstract: tyco applicator data Applicator STOP WIRE SIDE FEED APPLICATOR hand drill 690671 AN 7468 amp-o-lectric terminating machine
    Contextual Info: AMP-O-LECTRIC* Terminating Machine Conversion Kits 690675-2 and 692613-1 for Miniature Quick-Change Applicators ITEM NO. PART NO. Instruction Sheet 408-8022 06 FEB 09 DESCRIPTION Rev A QTY 1 690671–1 PLATE, Base 1 2 690672–2 MOUNT, Base 1 3 4–21002–4


    Original
    PDF

    threaded rod

    Abstract: underfloor duct FTRBN58
    Contextual Info: ELECTRICAL SOLUTIONS A. System Overview Fiber-Duct Mounting Brackets B1. Cable Ties Part Number B2. Cable Accessories FTRBE12, FTRBE58 FTRBE12M FTRBE12 FTRBE58 FTRBE12M FTRBN12, FTRBN58 FTRBN12M C2. Surface Raceway FTRBN58 FTRBN12M FUSB FUSB 1/2" 1 10


    Original
    FTRBE12, FTRBE58 FTRBE12M FTRBE12 FTRBE12M FTRBN12 FTRBN12, FTRBN58 FTRBN12M threaded rod underfloor duct PDF