Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    KIRDB0056EA Search Results

    KIRDB0056EA Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Contextual Info: INFRARED DETECTOR PbSe photoconductive detector P791/P2038/P2680 series, P3207-05 Detection capability up 5 µm range TE-cooled type Hamamatsu provides various types of PbSe photoconductive cells including room temperature operation types and thermoelectrically cooled


    Original
    p791/p2038/p2680p3207-05se-171kirda1020e02 PDF

    photoconductive cells characteristic

    Contextual Info: INFRARED DETECTOR PbSe photoconductive detector P791/P2038/P2680 series, P3207-05 Detection capability up 5 µm range TE-cooled type Hamamatsu provides various types of PbSe photoconductive cells including room temperature operation types and thermoelectrically cooled


    Original
    p791/p2038/p2680p3207-05se-171kirda1020e05+1photoconductive cells characteristic PDF

    Contextual Info: PbSe Photoconductive Cells Capable of Detecting to 5 ¡x m Range TE-cooled Types PbSe cells operates on the same principle as in PbS cells, but can be used to detect longer wavelengths up to or over 5 ¡x m. In particular, TE-cooled types ensure stable and reliable measurem ent over ex­


    OCR Scan
    kirdb0054eakirdb0056eap3207-04650nm PDF

    P9696

    Abstract: DETECTOR FLAME P3207-07 C1103-04 C3757-02 P4245 P4639 A3179 A3179-01 P9696-02
    Contextual Info: PbSe photoconductive detectors P9696 series P3207-07 Infrared detectors with fast response and high sensitivity in 5 Njm wavelength band Compared to other detectors used in the same wavelength regions, PbSe photoconductive detectors have faster response and


    Original
    p9696p3207-07se-171kspd1073e02+8detector flamec1103-04c3757-02p4245p4639a3179a3179-01p9696-02 PDF

    pyro charge

    Abstract: InSb spectral response hamamatsu photocell "golay"
    Contextual Info: Construction and Operating Characteristics Infrared radiation, d iscovered in 1800 by Sir W illiam H erchel, is electrom agnetic w aves in the w avelength range extending from 0.75 iirn to 1 0 0 0 /; m, in the range betw een visible light and m icrow aves.


    OCR Scan
    ta-25tkirdb0028ebpyro chargeinsb spectral response+2hamamatsu photocellgolay PDF

    Contextual Info: INFRARED DETECTOR PbSe photoconductive detector P791/P2038/P2680 series, P3207-05 Detection capability up 5 µm range TE-cooled type Hamamatsu provides various types of PbSe photoconductive cells including room temperature operation types and thermoelectrically cooled


    Original
    p791/p2038/p2680p3207-05se-171kirda1020e06 PDF

    photoconductive cells characteristic

    Abstract: DETECTOR FLAME flame detector C3757-02 Radiation Detector C1103-04 C4696 P4245 gas detector A3179
    Contextual Info: INFRARED DETECTOR PbSe photoconductive detector P791/P2038/P2680 series, P3207-05 Detection capability up 5 µm range TE-cooled type Hamamatsu provides various types of PbSe photoconductive cells including room temperature operation types and thermoelectrically cooled


    Original
    p791/p2038/p2680p3207-05se-171kirda1020e04+10photoconductive cells characteristicdetector flameflame detectorc3757-02radiation detectorc1103-04c4696p4245gas detectora3179 PDF

    thermistor 91

    Contextual Info: INFRARED DETECTOR PbSe photoconductive detector P791/P2038/P2680 series, P3207-05 Detection capability up 5 µm range TE-cooled type Hamamatsu provides various types of PbSe photoconductive cells including room temperature operation types and thermoelectrically cooled


    Original
    p791/p2038/p2680p3207-05se-171kirda1020e03+1thermistor 91 PDF

    co2 detector

    Contextual Info: PbSe photoconductive detectors P791/P2038/P2680 series P3207-07 Detection capability up to 5 m range TE-cooled type HAMAMATSU provides various types of PbSe photoconductive detectors including room temperature operation types and thermoelectrically cooled types. Cooled type PbSe photoconductive detectors offer higher sensitivity and improved S/N, and are widely


    Original
    p791/p2038/p2680p3207-07se-171kirda1020e07+1co2 detector PDF

    Contextual Info: Figure 12: Typical Spectral Response of PbS Cells PbS and PbSe Cells PbS and PbSe cells are photoconductive sem iconductors which de­ tect infrared radiation utilizing the fact that their resistance drops upon application o f incident infrared radiation. C om pared to other


    OCR Scan
    kirdc0012ea PDF

    P4115

    Abstract: B1919 G5832-11
    Contextual Info: PbSe Photoconductive Detectors Capable of detecting to 5 fim range TE-cooled types • High-speed response • Operates at room temperature Compared to other types of detectors used in the same wavelength range, PbSe cells have higher response speed and can also operate at


    OCR Scan
    kiroa0055ea0g0470p394ap3226-02+8p791-11p3207-04p4115k1713-01k3413-01p3981-01b1919g5832-11 PDF

    lem lt 100 p

    Abstract: P791-01
    Contextual Info: PbSe Photoconductive Detectors Capable of detecting to 5 pm range TE-cooled types • High-speed response • Operates at room temperature Com pared to other types o f detectors used in the same wavelength range, PbSe cells have higher response speed and can also operate at


    OCR Scan
    kirdb0054eakirdb0056eap3207-04650nm+3kirdb0057ealem lt 100 pp791-01 PDF

    Contextual Info: PbSe photoconductive detectors P9696 series P3207-07 Infrared detectors with fast response and high sensitivity in 5 Njm wavelength band Compared to other detectors used in the same wavelength regions, PbSe photoconductive detectors have faster response and


    Original
    p9696p3207-07se-171kspd1073e02 PDF

    Contextual Info: Two-color detectors K1713/K3413-01, -002 Wide spectral response range from UV through IR The K1713/K3413-01, -002 have a bi-level structure in which an infrared transmitting Si photodiode is mounted over an infrared detector element. This structure allows you to design instruments using the same optical path from UV through IR.


    Original
    k1713/k3413-01kird1029e07 PDF

    Infrared detectors

    Abstract: dark detector application ,uses and working
    Contextual Info: Compound semiconductor photosensors 1 InGaAs/GaAs PIN photodiodes 1-1 Characteristics 1-2 How to use 2 InGaAs APD 2-1 Operating principle 2-2 Characteristics 2-3 How to use CHAPTER 06 8 MCT HgCdTe photovoltaic detectors 8-1 Characteristics 8-2 How to use


    Original
    infrared detectorsdark detector application ,uses and working PDF

    Contextual Info: Two-color detectors K1713/K3413-01, -002 Wide spectral response range from UV through IR The K1713/K3413-01, -002 have a bi-level structure in which an infrared transmitting Si photodiode is mounted over an infrared detector element. This structure allows you to design instruments using the same optical path from UV through IR.


    Original
    k1713/k3413-01b1201kird1029e07 PDF

    pyroelectric PZT

    Contextual Info: Construction and Operating Characteristics Infrared radiation, discovered in 1800 by Sir William H erchel, is •QUANTUM TYPE DETECTORS electrom agnetic waves in th e w avelength range extending from Q uantum type detectors feature high detectivity and high-speed


    OCR Scan
    kirdb0114eakirdb0115eakirdb0116eakirdb0117ea+1pyroelectric pzt PDF

    TO8 16 pin Peltier

    Contextual Info: PbSe Photoconductive Cells Capable of Detecting to The 5 n m Range TE-cooled Types PbSe cells operates on the same principle as in PbS cells, but can be used to detect longer wavelengths up to or over 5 // m. In particular, T E -cooled types en su re stable and reliable m easurem ent o v e r ex ­


    OCR Scan
    kirdb0056eap3207650nmto8 16 pin peltier PDF