Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    JH RELAY Search Results

    JH RELAY Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DS3680D
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy
    ULN2003LVPWR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 Visit Texas Instruments Buy
    ULN2003V12PWR
    Texas Instruments Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 Visit Texas Instruments Buy
    ULN2003LVDR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 Visit Texas Instruments Buy
    DS3680DE4
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy

    Documents mentioning JH RELAY

    Document Partial File Text Tags Type PDF
    29vdc
    Ratings DPDT (2 form C) contacts. 5 amp @ 29VDC (JH-6D) 4PDT (4 form C) contacts, 2 amp @ 29VDC {JH-12D) Description Miniature OPDT or 4PDT relay High shock and vibration performance Temperature range: 65" to i I2 5 ’ C Low level switching contacts (by specification)
    OCR Scan PDF
    JH 30 AMP (1 Form X) POWER RELAY WITH SPACE
    JH 30 AMP (1 Form X) POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS UL File No.: E57520; CSA File No.: LR26550 • Many safety-oriented characteristics incorporated Contact gap: more than 3 mm for 1 Form A and 2 Form A Breakdown voltage for N.O. contact: 2,000 V AC between contacts
    OCR Scan PDF
    digital pressure gauge
    Model JH High Pressure Digital Pressure Gauge DESCRIPTION Using high pressure autoclave fittings, the Series JH digital pres- analog output. The Model JHX provides a 0 Vdc to 5 Vdc output sure test gauge with 0.2 % full scale accuracy uses transducer with two programmable limits and relays for process control
    Original PDF
    lr26550
    JH 30 AMP (1 Form X) POWER RELAY WITH SPACE SAVING DESIGN 56 2.205 33 1.299 JH-RELAYS UL File No.: E43028; CSA File No.: LR26550 • Many safety-oriented characteristics incorporated Contact gap: more than 3 mm for 1 Form A and 2 Form A Breakdown voltage for N.O. contact: 2,000 V AC between contacts
    Original PDF
    JH 30 AMP (1 Form X) POWER RELAY WITH SPACE
    JH 30 AMP (1 Form X) POWER RELAY WITH SPACE SAVING DESIGN 56 2.205 33 1.299 JH-RELAYS UL File No.: E43028; CSA File No.: LR26550 • Many safety-oriented characteristics incorporated Contact gap: more than 3 mm for 1 Form A and 2 Form A Breakdown voltage for N.O. contact: 2,000 V AC between contacts
    Original PDF
    High Pressure Digital Pressure Gauge Model JH
    High Pressure Digital Pressure Gauge Model JH Pressure Ranges from 15,000 to 60,000 PSI Gage 2 Programmable Limits and Relays (Optional) Accuracy - 0.2% Full Scale High & Low Detection - Microprocessor Based 4-20 mA (2 wire) and 0-5 VDC Analog Outputs (Optional)
    Original PDF
    jh relay
    VDE 30 AMP POWER RELAY WITH SPACE SAVING DESIGN JH RELAYS FEATURES 56 2.205 33 1.299 35.8 1.409 mm inch • Many safety-oriented characteristics incorporated Contact gap: more than 3 mm .118 inch for 1 Form A and 2 Form A Breakdown voltage for N.O. contact:
    Original PDF
    AUTOMOTIVE SELECTION Autnmntive (irade Single
    AUTOMOTIVE SELECTION Autnmntive (irade Single Linear Regulators OUTPUT CURRENT < 150mA Yæ 5V Unless otherwise staled No MICROPOWER GUIDES I Yes No JH ENABLE Yes ENABLE No £ - CS8221 RESET - CS8321 Yes L, 1— CS8271 (adj) Yes 1 Yes CS9201 RESET No Yes No
    OCR Scan PDF
    3 JHÊIE HIGH PERFORMANCE MINIATURE RELAYS Relays
    3 JHÊIE HIGH PERFORMANCE MINIATURE RELAYS Relays for advanced technology SD-RELAYS CQC File N o.:C Q C 0 2 0 0 1 0 0 2 1 2 3 •20A sw itching ca p a bility Ultra-m iniature, standard PC la y o u t . •Low power consum ption 0.6W only • H ig h resistan cetovibrationand sh ock
    OCR Scan PDF
    electromatic
    ELECTROMATIC CONTROLS E5E lu RT aos 3®oa5t2 2h r ^ V - X CMmON ----Í M J ,3 t ■■■…,lw fOKWMO • — i <---- SOUD 5TXTE REVÊRS*« VQ JH ' ■ 3E13D74 QO.DEMMb 7 ■ RT 202 380 - xx - xx fi éi, fi & “ 1 *— D ^A .
    OCR Scan PDF
    Remote Pressure Digital Pressure Gauge Model JR
    Remote Pressure Digital Pressure Gauge Model JR Portable Battery Powered Available 2 Programmable Limits and Relays (Optional) Test Gauge Accuracy - 0.2% Full Scale High & Low Detection - Microprocessor Based Ranges to 60,000 PSI - Gage, Absolute, Vacuum or Compound
    Original PDF
    digital pressure gauge
    Model JR Remote Pressure Digital Pressure Gauge DESCRIPTION With a 6-ft microchange cable connection, the Model JR digital grammable limits and relays for process control or alarm indica- pressure test gauge with 0.2 % full scale accuracy uses trans- tion. The Model JRW is powered by one or two common
    Original PDF
    lp561g
    GaAs IRED S PHOTO-TRIAC TLP561G TRIA C DRIVER PROGR AMMABL E C O N T R O L L E R S A C - O U T P U T MODUL E SO LID STATE RELAY The TOSH I B A TLP561G consists of a zero voltage crossing turn-on photo-triac optically coupled to a gallium arsenide infrared emitting diode in a six lead plastic
    OCR Scan PDF
    tlp3061
    TLP3061,3062,3063 G a A s IRED S P H O T O -T R IA C (T L P 3 0 6 1 ) OFFICE M A C H IN E . H O U S E H O L D USE E Q U IP M EN T . T R IA C DRIVER. SO L ID STATE RELAY. The TOSHIBA TLP3061, TLP3062 and TLP3063 consist of a zero voltage crossing turn-on photo-triac optically coupled to a gallium
    OCR Scan PDF
    3 ,, SAHYOU RELAYS ¡ » " “ ' g " R .ia v R e la y
    3 ,, SAHYOU RELAYS ¡ » " “ ' g " R .ia v R e la y s fo r a d v a n c e d te c h n o lo g y M U tO IT IO tlv e r ie ia y S A R L-S eries F eatures • 4 0A high s w itc h in g c a p a b ility . • 1 Form C and 2 Form A c o n ta c t c o n fig u ra tio n a v a ila b le .
    OCR Scan PDF
    mj16006
    MOTORCLA SC X ST R S/R 1 EE F D b3L 7254 I MOTOROLA d O flS ia ? 1 | MJ16006 MJH16006 MJ16008 MJH16008 SEMICONDUCTOR TECHNICAL DATA D e s ig n e r s D a t a S lio o t 8.0 AMPERE SW ITCH M O D E III S E R IE S NPN SILICO N PO W ER T R A N S IS T O R S NPN SILICON
    OCR Scan PDF
    mj13090
    motorola sc -c x s t r s / 6367254 r f > MOT OROL A Tb SC ÍXSTRS/R DE ^ h d b i ' r i b W F) 96D 81082 DDfllOfis J~ _D T ' 3 3 -/3 MOTOROLA MJ13090 MiH13090 MJ13091 MJH13091 SEM ICO NDUCTO R TECHNICAL DATA e s if ín c i- ’ s ^ D a tifíS h o e t 15 AMPERE
    OCR Scan PDF
    CC-U/STDR (D) Betriebs- und Montageanleitung
    CC-U/STDR (D) Betriebs- und Montageanleitung Universalsignalwandler für Standardsignale, mit 2 Schwellwert-Relaisausgängen, CC Reihe (F) Hinweis: Diese Betriebs- und Montageanleitung enthält nicht sämtliche Detailinformationen zu allen Typen der Produktreihe und kann auch nicht jeden Einsatzfall der
    Original PDF
    nc14006
    NC14006 000816 Universal signal converter for standard signal with 2 threshold relay outputs (3-way isolated) C.A.I.S. UNI - R Analog signal converters C.A.I.S. series 40 000 width 22,5 mm .886" M L K Plug-in omniconnect terminals Value R1: upper threshold
    Original PDF
    Miniature General Purpose Relay HY General
    Miniature General Purpose Relay HY General purpose 5,7 amp Plug in Power Relay, available in 2PCO, 3PCO and 4PCO ❚ Arc barriers prevent flashover between contacts ❚ Manual operator for circuit testing with latch facility colour coded for AC/DC identification
    Original PDF
    2sk1356
    TO SHIBA 2SK1356 Industrial Applications Field Effect Transistor Unit in mm Silicon N Channel MOS Type (rc-MOS II) 1 O í 0.3 High Speed, High Current DC-DC Converter, 0 3.2 ¿0 .2 2.7 ± 0 .2 Relay Drive and Motor Drive Applications Features • High Voltage
    OCR Scan PDF