ISO 13359 Search Results
ISO 13359 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| PTH08T261WAS | Texas Instruments | 3-A, 4.5V to 14V Input, Ceramic Cap Version, Non-Iso, Wide Output, Adjust Power Module w/ TurboTrans 10-Surface Mount Module -40 to 85 |
|
||
| PTH04T231WAD | Texas Instruments | 6-A, 2.2-V to 5.5-V Input, Ceramic Cap Version, Non-Iso, Wide-Output, Adj Power Module w/TurboTrans 10-Through-Hole Module -40 to 85 |
|
|
|
| PTH04T241WAD | Texas Instruments | 10-A, 2.2-V to 5.5-V Input, Ceramic Cap Version, Non-Iso, Wide-Output, Adj Power Module w/TurboTrans 11-Through-Hole Module -40 to 85 |
|
|
|
| PTH04T261WAD | Texas Instruments | 3-A, 2.2V to 5.5V Input, Ceramic Cap Version, Non-Iso, Wide Output, Adj Power Module with TurboTrans 10-Through-Hole Module -40 to 85 |
|
|
|
| PTH08T261WAZT | Texas Instruments | 3-A, 4.5V to 14V Input, Ceramic Cap Version, Non-Iso, Wide Output, Adjust Power Module w/ TurboTrans 10-Surface Mount Module -40 to 85 |
|
Documents mentioning ISO 13359
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| d184s073u02 | Data Sheet D184S073U02 Level 0: Information ■ Function – Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, pastes and sludges with an electrical conductivity of at least 20 µS/cm (opt. 0.5 µS/cm). ■ Applications |
Original | ||||
| d184s044u02 | FieldIT Data Sheet D184S044U02 Electromagnetic Flowmeter FXE4000 (COPA XE/MAG XE) ■ The Electromagnetic Flowmeter (EMF) can be used to accurately measure the flowrate of liquids which have an electrical conductivity greater than 5 µS/cm (20 µS/cm for demineralized water). |
Original | ||||
| d184s031u02 | Data Sheet D184S031U02 FieldIT Electromagnetic Flowmeter COPA-XM / MAG-XM ■ Function – The flowrate of liquids, slurries, pastes and sludges can be measured accurately with the electromag netic flowmeter – Minimum conductivity 5 µS/cm – The measurement system consists of a flowmeter |
Original | ||||
| d184s073u02 | Data Sheet D184S073U02 Electromagnetic Flowmeter FSM4000 Pos: 1 /Titelblätter / Copyright/DB/Durchfluss/FSM4000 @ 34\mod_1259573431187_3101.doc @ 310891 @ Function - Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, |
Original | ||||
| d184s043u02 | Data sheet D184S043U02 Electromagnetic Flowmeter FXT4000 (COPA-XT) 2-Wire Compact Design with Pulsed DC Excitation ■ Function – Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, pulps, slurries and sludges – Minimum fluid conductivity 20 μS/cm |
Original | ||||
| feh300 | Data Sheet DS/FEH300-EN Electromagnetic Flowmeter HygienicMaster FEH300 Intuitive operation - Softkey-based functionality - “Easy Set-up” function Non-contact buttons - Enable the device to be parameterized without the need to open the housing Diagnostics for real-life situations |
Original | ||||
| flowmeter | Data Sheet D184S024U02 Electromagnetic Flowmeter FXP4000 (PARTI-MAG II) for Full and Partially Full Pipelines (Free and Surface Pipelines) Model DP41F and DP46F ■ The flowrate of liquids and slurries with electrical conductivities of at least 50 mS/cm up to 10 mS/cm |
Original | ||||
| fep300 | Data Sheet DS/FEP300-EN Electromagnetic Flowmeter ProcessMaster FEP300 Intuitive operation - Softkey-based functionality - “Easy Set-up” function Non-contact buttons - Parameterization of the device without the need to open the housing Diagnostics for real-life situations |
Original | ||||
| Data Sheet DS/FEH500-EN Electromagnetic Flowmeter | Data Sheet DS/FEH500-EN Electromagnetic Flowmeter HygienicMaster FEH500 Intuitive operation - Softkey-based functionality - “Easy Set-up” function Diagnostics for real-life situations - Status messages in accordance with NAMUR - Help texts in the display |
Original | ||||
| fep500 | Data Sheet DS/FEP500-EN Electromagnetic Flowmeter ProcessMaster FEP500 Intuitive operation - Softkey-based functionality - “Easy Set-up” function Diagnostics for real-life situations - Status messages in accordance with NAMUR - Help texts in the display |
Original | ||||
| cd4510b | G E SOLID STATE 01 38 75 081 DE I 3Û7S □Al GQ133S7 3 01E G E S O L I D ST A T E 13357 D T ' CD4510B, CD4516B Types CMOS Presettable Up/Down Counters H igh-Voltage Types (2 0 -V o lt Rating) C D4510B .Features: ■ Medium-speed operation ~ fci_ = 8 M Hz ty p . a t 10 V |
OCR Scan | ||||
| d184b140u02 | Operating Instruction D184B140U02 Valid for software versions C.10 and higher Model FSM4000-SE41F FSM4000-SE21 FSM4000-SE21F FSM4000-S4 Electromagnetic Flowmeter FSM4000 Blinder Text Electromagnetic Flowmeter FSM4000 Operating Instruction D184B140U02 08.2010 |
Original | ||||
| fex300 | Operating Instruction OI/FEX300/FEX500-EN Valid from software version • 01.01.00 for HART • 00.01.00 for PROFIBUS PA or FOUNDATION Fieldbus Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500 Blinder Text Electromagnetic Flowmeter ProcessMaster, HygienicMaster |
Original | ||||
| Weidmüller – Partner in Industrial Connectivity 2 | Weidmüller – Partner in Industrial Connectivity 2 PCB terminal blocks, PCB connectors, panel feedthrough terminal blocks and electronics housings Catalogue 2013 Let’s connect. Catalogue 2013 OMNIMATE – device connectivity As experienced experts we support our customers and partners around the world |
Original | ||||
|
|
||||||
| Discontinued and Superseded Stock Number History. | Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item. |
Original | ||||
NEED IT NOW? BUY REMAN! SEE PAGE lxx xx xvi SOLUTIONS, SOLUTIONS… Q A r e q u a l i t y, c o s t , a n d t i m e i m p o r t a n t to you? A ELECTRICAL SOUTH! Q Do you spend too much of your valuable time dealing with too m a n y d i ff e r e n t r e p a i r v e n d o r s ? |
Original | |||||
| melsec | MITSUBISHI ELECTRIC Ïðîãðàììèðóåììûå Ëîãè÷åñêèå Êîíòðîëëåðû MELSEC FX1S FX1N FX2N FX2NC Òåõíè÷åñêèé êàòàëîã 2003 Íîâîå â êàòàëîãå Íîâûå û ïðîäóêò 2003 MELSEC FX2NC Íîâàÿ ñåðèÿ FX2NC ÿâëÿåòñÿ àíàëîãîì ñåðèè FX2N. Ïðåäëàãàÿ òå æå |
Original | ||||
| m44c092 | M44C092 M44C892 Temic S e m i c o n d u c t o r s Low-Current Microcontrollers for Wireless Communication The M44C092 and M44C892 are members of TEMIC Semiconductors ’ family of 4-bit single-chip microcontrollers. They offer highest integration for IR and RF data communication, remote-control and phase-control applications. The |
OCR Scan | ||||
| ELMARK Has been a registered trademark for Europe | ELMARK Has been a registered trademark for Europe since the year of 2000 and is part of the international company ELMARK HOLDING SC. Our company is licensed for the manufacture of the full range of professional low-voltage electrical equipment. The Headquarters of ELMARK HOLDING AD are situated in Varna, Bulgaria. There is our logistics center which |
Original | ||||
| Discontinued and Superseded Stock Number History. | Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item. |
Original | ||||
| Technology in connectors™ Leiterplatten | Technology in connectors™ Leiterplatten Steckverbinder CONEC Elektronische Bauelemente GmbH Ostenfeldmark 16 59557 Lippstadt Germany Tel. +49 2941 765-0 Fax +49 2941 76565 E-Mail info@conec.de www.conec.com Leiterplatten Steckverbinder CONEC s.r.o. Loucka 119 |
Original | ||||
| pcb connectors | Technology in connectors™ PCB Connectors CONEC Elektronische Bauelemente GmbH Ostenfeldmark 16 59557 Lippstadt Germany Tel. +49 2941 765-0 Fax +49 2941 76565 E-Mail info@conec.de www.conec.com PCB Connectors CONEC s.r.o. Loucka 119 76325 Ujezd Czech Republic |
Original | ||||
| Issued March 1988 8773 Data Library Contents list | Issued March 1988 8773 Data Library Contents list and semiconductor device type index Data library contents Subject Title Number Communications Equipment B. T. telephone connection system Digital compact paging system Escort (2 + 6) telephone switching system |
OCR Scan | ||||
| Discontinued and Superseded Stock Number History. | Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item. |
Original | ||||
| Issued November 1986 7376 r Contents list and | Issued November 1986 7376 r Contents list and semiconductor device type index data Data library contents Issue Date Subject Title Number Communications Equipment B.T. telephone connection system Digital compact paging system 'Minimaster 3' (2+10) telephone switching system |
OCR Scan | ||||