Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IPN 14 S Search Results

    IPN 14 S Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    74AC11000N
    Texas Instruments Quadruple 2-Input Positive-NAND Gates 16-PDIP -40 to 85 Visit Texas Instruments Buy
    74AC11004DW
    Texas Instruments Hex Inverters 20-SOIC -40 to 85 Visit Texas Instruments Buy
    74AC11074D
    Texas Instruments Dual Positive-Edge-Triggered D-Type Flip-Flops With Clear and Preset 14-SOIC -40 to 85 Visit Texas Instruments Buy
    74AC11244PWR
    Texas Instruments Octal Buffers/Drivers 24-TSSOP -40 to 85 Visit Texas Instruments Buy
    74AC11257N
    Texas Instruments Quadruple 2-Line To 1-Line Data Selectors/Multiplexers With 3-State Outputs 20-PDIP -40 to 85 Visit Texas Instruments Buy

    IPN 14 S Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    CAS 6-NP

    Abstract: 15-NP 25-NP 50Np lts 6 np CAS 25-NP lem cas lem lts series
    Contextual Info: Current Transducer CAS series IPN = 6, 15, 25, 50 A Ref: CAS 6-NP, CAS 15-NP, CAS 25-NP, CAS 50-NP For the electronic measurement of current: DC, AC, pulsed., with a galvanic isolation between the primary high power and the secondary circuit (electronic circuit).


    Original
    15-NP, 25-NP, 50-NP 94-V0 CAS 6-NP 15-NP 25-NP 50Np lts 6 np CAS 25-NP lem cas lem lts series PDF

    lem htb 50

    Abstract: 100-P 3P-2510 htb 150 100-TP1 3p25
    Contextual Info: Current Transducers HTB 50.400-P and HTB 50.100-TP IPN DC = ± 50 . 400 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit).


    Original
    400-P 100-TP 50-TP1) 100-P, 100-TP1) 200-P 300-P 635x0 lem htb 50 100-P 3P-2510 htb 150 100-TP1 3p25 PDF

    2p25

    Abstract: lem htb 50
    Contextual Info: Current Transducers HTB 50.400-P/SP5 and HTB 50.100-TP/SP5 IPN = 50 . 400 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit).


    Original
    400-P/SP5 100-TP/SP5 50-P/SP5, 50-TP/SP51) 100-P/SP5, 100-TP/SP51) 200-P/SP5 300-P/SP5 635x0 2p25 lem htb 50 PDF

    transformerless power inverter

    Abstract: leakage current transducer AC lem ct 02-p CT 0.4-TP LEM
    Contextual Info: Current Transducers CT 0.1 . 0.4-P For the electronic measurement of small currents: AC,DC, mixed, with a galvanic isolation between the primary circuit and the secondary circuit. IPN = ± 100.400 mA VOUT = ± 5 V Electrical data Primary nominal current rms


    Original
    500Hz. transformerless power inverter leakage current transducer AC lem ct 02-p CT 0.4-TP LEM PDF

    lem 400-P

    Abstract: 100-P 400.p
    Contextual Info: Current Transducers HTB 50 . 400-P and HTB 50 . 100-TP IPN = 50 . 400 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit).


    Original
    400-P 100-TP 50-TP1) 100-P, 100-TP1) 200-P 300-P 635x0 lem 400-P 100-P 400.p PDF

    lem 400-P

    Abstract: 2p25
    Contextual Info: Current Transducers HTB 50 . 400-P/SP5 and HTB 50 . 100-TP/SP5 For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 50 . 400 A


    Original
    400-P/SP5 100-TP/SP5 50-P/SP5, 50-TP/SP51) 100-P/SP5, 100-TP/SP51) 200-P/SP5 300-P/SP5 635x0 lem 400-P 2p25 PDF

    100-TP1

    Abstract: lem 400-P 100-P
    Contextual Info: Current Transducers HTB 50 . 400-P and HTB 50 . 100-TP For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). IPN = 50 . 400 A


    Original
    400-P 100-TP 50-TP1) 100-P, 100-TP1) 200-P 300-P 635x0 100-TP1 lem 400-P 100-P PDF

    LTS 6-NP

    Abstract: lem lts operation principle of lts 6-NP lts 6 np hall current transducer lts 6-np lem 703 lts 25 np
    Contextual Info: Current Transducer LTS 6-NP IPN = 6 At For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data I PN IP Î PDC VOUT


    Original
    PDF

    BUSBAR calculation

    Abstract: DHR-C10
    Contextual Info: IPN = 100.1000 A AC/DC Current transducer DHR-C10 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). True RMS 0-10V voltage output.


    Original
    DHR-C10 24VDC BUSBAR calculation DHR-C10 PDF

    LEM Hais 50-P

    Abstract: HAIS 200-P lem module 100A LEM Hais 100-P 100-P HAIS 50-P
    Contextual Info: Current Transducer HAIS 50.400-P and HAIS 50.100-TP IPN = 50 . 400 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). All Data are given with a R L = 10 kΩ


    Original
    400-P 100-TP 50-TP1) 100-P, 100-TP1) 150-P 200-P LEM Hais 50-P HAIS 200-P lem module 100A LEM Hais 100-P 100-P HAIS 50-P PDF

    BUSBAR calculation datasheet

    Abstract: BUSBAR calculation
    Contextual Info: AC/DC Current transducer DHR-C5 IPN = 100.1000 A The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). True RMS 0-5V voltage output.


    Original
    24VDC BUSBAR calculation datasheet BUSBAR calculation PDF

    ES300C

    Abstract: he14 connector ES500 ES500C ES1000C ES2000C ES100C ES500-9672 ES300 ES500F
    Contextual Info: ES Industry Current Sensors Utilisation ES100 ES300 ES500 ES100C ES300C ES500C ES500-9672 - ES300S ES500S ES500-9673 ES100F ES300F ES500F ES500-9674 100 ±150 ±150 300 1ms/hour 48 105 10 82 1000 100 ≤±0.5 ≤±1 ≤±2.5 ≤±0.4 ≤0.1 ≤10 ≤80 ≤1


    Original
    ES100 ES300 ES500 ES100C ES100F ES300C ES300S ES300F ES500C ES500S he14 connector ES500 ES1000C ES2000C ES500-9672 ES300 ES500F PDF

    BUSBAR calculation

    Abstract: c420 diode C420 DHR-C420 VFD WITH AC AND DC POWER cable 4-20 24 Vcc C-420
    Contextual Info: IPN = 100.1000 A AC/DC Current transducer DHR-C420 The transducer for the electronic measurement of DC & distorted AC waveform currents, with galvanic isolation between the primary circuit power and the secondary circuit (measurement). True RMS 4-20mA current output.


    Original
    DHR-C420 4-20mA 24VDC BUSBAR calculation c420 diode C420 DHR-C420 VFD WITH AC AND DC POWER cable 4-20 24 Vcc C-420 PDF

    Contextual Info: Current Transducer HXS 20-NP/SP2 IPN = 5 - 10 - 20 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). All Data are given with a R L = 10 kΩ


    Original
    20-NP/SP2 PDF

    HY50-P

    Abstract: HY50P
    Contextual Info: Current Transducers, HY50-P IPN For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). = 50 A Electrical data Primary nominal r.m.s. current


    Original
    HY50-P 50/60Hz, HY50-P HY50P PDF

    100-P

    Contextual Info: Current Transducer HTY 50.100-P IPN = 50 . 100 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data Primary nominal


    Original
    100-P 100-P PDF

    lem hy 10-p

    Abstract: ho 10-p HY-05 HY Electronic R/HY-05+HYCOM
    Contextual Info: IPN Current Transducers HY 5 to 25-P/SP1 For the electronic measurement of currents : DC, AC, pulsed., with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit) with unipolar power supply. = 5 . 25 A


    Original
    25-P/SP1 50/60Hz, 25-P/S lem hy 10-p ho 10-p HY-05 HY Electronic R/HY-05+HYCOM PDF

    hxs 20-np/sp30

    Abstract: HXS 20-NP
    Contextual Info: Current Transducer HXS 20-NP/SP30 IPN = 5 - 10 - 20 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). All Data are given with a R L = 10 kΩ


    Original
    20-NP/SP30 hxs 20-np/sp30 HXS 20-NP PDF

    100-P

    Contextual Info: Current Transducer HTY 50 . 100-P IPN = 50 . 100 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). Electrical data Primary nominal


    Original
    100-P 50/60Hz, 100-P PDF

    50-NP

    Contextual Info: Current Transducer HXS 50-NP/SP2 IPN = 12.5 - 25 - 50 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). All Data are given with a R L = 10 kΩ


    Original
    50-NP/SP2 50-NP PDF

    lem hxs 50 np

    Abstract: HXS20-NP 10-NP
    Contextual Info: Current Transducer HXS 10-NP/SP3 IPN = 10 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). DUAL PHASE All Data are given with a R L = 10 kΩ


    Original
    10-NP/SP3 lem hxs 50 np HXS20-NP 10-NP PDF

    cksr series

    Contextual Info: Current Transducer CKSR series IPN = 6, 15, 25, 50 A Ref: CKSR 6-NP, CKSR 15-NP, CKSR 25-NP, CKSR 50-NP For the electronic measurement of current: DC, AC, pulsed., with galvanic separation between the primary and the secondary circuit. Features Applications


    Original
    15-NP, 25-NP, 50-NP 22March 2013/version cksr series PDF

    lem hxs 50 np

    Abstract: ac to dc 5V dc supply 50-NP 061004
    Contextual Info: IPN = 12.5 - 25 - 50 A Current Transducer HXS 50-NP For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). All Data are given with a R L = 10 kΩ


    Original
    50-NP lem hxs 50 np ac to dc 5V dc supply 50-NP 061004 PDF

    lem hxs 50 np

    Contextual Info: Current Transducer HXS 20-NP/SP2 IPN = 5 - 10 - 20 A For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit high power and the secondary circuit (electronic circuit). 45001 Electrical data


    Original
    20-NP/SP2 lem hxs 50 np PDF