IEC MCB Search Results
IEC MCB Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TPD6E05U06RVZR | Texas Instruments | 6-Channel Ultra-Low-Capacitance IEC ESD Protection Diodes 14-USON -40 to 125 |
|
|
|
| TPD1E05U06DPYT | Texas Instruments | 1-channel ultra-low-capacitance IEC ESD protection diode 2-X1SON -40 to 125 |
|
|
|
| TPD1E05U06DPYR | Texas Instruments | 1-channel ultra-low-capacitance IEC ESD protection diode 2-X1SON -40 to 125 |
|
|
|
| TPD4E05U06DQAR | Texas Instruments | 4-Channel Ultra-Low-Capacitance IEC ESD Protection Diode 10-USON -40 to 125 |
|
|
|
| V62/15608-01XE | Texas Instruments | 3.3-V Supply RS-485 With IEC ESD Protection 8-SON -55 to 125 |
|
|
Documents mentioning IEC MCB
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| . S 2 5 0 & S270 240VAG Class b ^ 5 tJ "L IT E M | . S 2 5 0 & S270 240VAG Class b ^ 5 tJ "L IT E M Approvals: No. of poles: Tripping characteristic: Rated currents: Rated voltage: UL1077 CSA C22.2 VDE 0641 IEC 898 IEC 947 UL1077 CSA C22.2 VDE 0660 IEC 898 IEC 947 1,2,3, 1+N.3+N 1,2,3,4, 1+N,3+N L K 6 to 32A |
OCR Scan | ||||
| circuit-breakers | I12_006-007_b_G.fm Seite 6 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures |
Original | ||||
| circuit-breakers | I12_004-005_b_G.fm Seite 4 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures |
Original | ||||
| circuit-breakers | I12_006-007_b_G.fm Seite 6 Donnerstag, 16. September 2004 12:28 12 FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) FAZ Miniature Circuit-Breakers Switching Capacity 15 kA (IEC/EN 60947-2) Miniature Circuit-Breakers, MCB Enclosures, Fuse Enclosures |
Original | ||||
| 1E EJB/EJW Enclosures For IEC Applications | 1E EJB/EJW Enclosures For IEC Applications Applications: EJB/EJW IEC ATEX Enclosures are used in threaded rigid conduit systems in hazardous areas: • To function as a splice box, pull box, or equipment and device enclosure • Indoors and outdoors Features: |
Original | ||||
| 12/037 Moeller HPL0211-2001/2002 FAZ tripping | 12/037 Moeller HPL0211-2001/2002 FAZ tripping characteristics at 30 °C: R to IEC/EN 60 947 1.05 1.30 1.13 1.45 FAZ tripping characteristics at 30 °C: B, C, D to IEC/EN 60 898 Specified non-tripping current I nt = 1.13 ҂ I n for t > 1 h Specified tripping current |
Original | ||||
| mn85560 | LSIs for MPEG MN85560 MPEG2 Video Encoder ■ Overview The MN85560 is an MPEG2 video encoder that outputs encoded data that conform to the ISO/IEC 1318-2 (MPEG2 video) Main Profile@Main Level and ISO/IEC 1172-2 (MPEG1 video) standards. ■ Features • Incorporates the image input filters used for front-end processing. |
Original | ||||
| mn85560 | LSIs for MPEG MN85560 MPEG2 Video Encoder ■ Overview The MN85560 is an MPEG2 video encoder that outputs encoded data that conform to the ISO/IEC 1318-2 (MPEG2 video) Main Profile@Main Level and ISO/IEC 1172-2 (MPEG1 video) standards. ■ Features • Incorporates the image input filters used for front-end processing. |
Original | ||||
| nhxb06 | DATA SHEET FOR DOMESTIC MCBs TYPE B Catalogue Numbers: NHXB06, NHXB10, NHXB16, NHXB20, NHXB32, NHXB40, NHXB50 Technical Specification Standards Amperage Tripping Characteristic Rated Operational Voltage Rated Switching Capacity Icn acc. to IEC 60898-1 Insulation Coordination |
Original | ||||
| an10875 | AN10875 IEC 60601-1-8 audible alert generator using the LPC1700 Rev. 01 — 1 October 2009 Application note Document information Info Content Keywords IEC60601-1-8, LPC1700, Cortex-M3, MCB1700, Goertzel, Medical Alerts Abstract This application note describes an algorithmic method of generating |
Original | ||||
| linears | DC Power Supplies Commercial/Medical International + Linears International + Linears Summary: • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC approved— models to UL/CSA 60950; EN/IEC60950-1 |
Original | ||||
| DC Power Supplies Commercial/Medical | DC Power Supplies Commercial/Medical International + Linears International + Linears Summary: • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC approved— models to UL/CSA 60950; EN/IEC60950-1 |
Original | ||||
| Commercial/Medical International + Linears | Commercial/Medical International + Linears Medical Commercial FEATURES • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC approved—68 models to UL1950; CSA C22.2 No. 950 L3; TUV certified to EN60950 |
Original | ||||
| Commercial/Medical International + Linears | Commercial/Medical International + Linears Medical Commercial FEATURES • World-wide ac input ranges and safety standards • Industry standard packages • Commercial UL/CSA TUV/IEC approved—68 models to UL1950; CSA C22.2 No. 950 L3; TUV certified to EN60950 |
Original | ||||
|
|
||||||
| protection of transformers, primary and secondary | protection of transformers, primary and secondary circuits ■ Protection of transformers In accordance with the IEC/EN 61558 standard, transformers must be protected against overload and short-circuit conditions which may occur during normal operation. The standard does not specify the type or location of the protective |
Original | ||||
| Relion® Protection and control 650 series IEC | Relion® Protection and control 650 series IEC 61850 Communication Protocol Manual Document ID: 1MRK 511 242-UEN Issued: February 2011 Revision: Product version: 1.1 © Copyright 2011 ABB. All rights reserved Copyright This document and parts thereof must not be reproduced or copied without written |
Original | ||||
| motores | Guardamotores MS Con protección contra sobrecarga y cortocircuito, sensibilidad al fallo de fase de acuerdo a IEC 947-4-1, DIN VDE 0660 Part 102 Debido a su alta capacidad de ruptura con alta limitación de corriente, los guardamotores MS suministran una óptima protección para motores |
Original | ||||
| sn201 | The new SN201 circuit-breaker Ideal profile 2CSC402001B0201 New miniature circuit-breakers 1P+N in one module SN201 Armonia tecnologica SN201 series is compliant with IEC EN 60898-1 standards 2 A universal model Perfectly compatible with the whole range. The System pro M compact® complete miniature system, |
Original | ||||
| LEISTUNGSLASER HIGH POWER LASERS LEISTUNGSLASER | LEISTUNGSLASER HIGH POWER LASERS LEISTUNGSLASER HIGH-POWER LASERS SAFETY INSTRUCTIONS Products incorporating laser diodes will normally be classified as class 4 laser products according to IEC 60825-1 in a normal operation mode. Direct exposure of the human eye with laser radiation is therefore hazardous and must be strictly avoided. |
Original | ||||
| RS Stock-Nos. 422-9738 ff control transformers | RS Stock-Nos. 422-9738 ff control transformers single phase Conform to IEC/EN 61558-2-2; 2-6 (24V) and 2-4 (>24V) - UL 506 and CSA 22.2 - No. 66 Single-phase 50-60 Hz - class I Insulation voltage between windings : 4 510 V Max. ambient operating temperature : 60°C |
Original | ||||
| 5sy6 | © Siemens AG 2008 5SY6 Miniature Circuit Breakers High-capacity range, 6 kA ■ Application • Un: 230/400 V, 50-60 Hz, applicable in networks up to 250/440 V AC, 60 V DC per pole • Standards EN 60898, (VDE 0641 Part 11), IEC 60898 • Supplementary components can be retrofitted |
Original | ||||
| rectified power supplies rectified power supplies | rectified power supplies rectified power supplies single phase filtered single phase filtered Conform to IEC/EN 61558-2-6, UL 508 CAN/CSA - 60950 and EN 61131-2 and EN 60204 standards Primary : 230-400 V ±15 VÒ single phase 50-60 Hz - class I Secondary : 12 V or 24 V— |
Original | ||||