HAZARDOUS AREA Search Results
HAZARDOUS AREA Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| LM110H | Rochester Electronics LLC | LM110 - Buffer Amplifier, Voltage Follower, Metal CAN |
|
||
| CS-SASDDP8282-000.5 | Amphenol Cables on Demand | Amphenol CS-SASDDP8282-000.5 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 0.5m | |||
| CS-SASDDP8282-001 | Amphenol Cables on Demand | Amphenol CS-SASDDP8282-001 29 position SAS to SATA Drive Connector Dual Data Lanes Cable 1m | |||
| LBWA1UZ1PS | Murata Manufacturing Co Ltd | Wireless LAN Circuit | |||
| LBWA1UZ1GC-901 | Murata Manufacturing Co Ltd | Wireless LAN Circuit |
HAZARDOUS AREA Datasheets Context Search
| Catalog Datasheet | Type | Document Tags | |
|---|---|---|---|
14CE100
Abstract: switch atex
|
Original |
94/9/ecen5001414ce100switch atex | |
392 t4a
Abstract: T4A 392 UL1598 HZC-02-150-1111-201
|
Original |
hzc-02-150-1111-201hzc-02-150-1111-301hzc-3003hzc-3001+4 | |
EN500014
Abstract: EN50020 barrier network fuse
|
Original |
en50020250vac/vdc635mmen500014+1 | |
|
Contextual Info: INTRINSIC SAFETY HAZARDOUS AREA 3 INTRODUCTION Intrinsically safe equipment is defined as “equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous |
Original |
isa-rp12k-104 | |
|
Contextual Info: Intrinsic Safety HAZARDOUS AREA SAFE AREA 3 Introduction Intrinsically safe equipment is defined as “equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture |
Original |
isa-rp12 | |
MTL5113P
Abstract: 5114P Proximity Detector MTL5114P proximity detector sensor
|
Original |
mtl5113p5114pmtl5113p/5114pmtl5114p+2 | |
|
Contextual Info: Data Sheet Data sheet ASO Safety Contact Mat - Used for safeguarding of hazardous areas - Prevents hazardous motion by triggering stop signals - Material assures impermeability of oils, water and dirt - Individual designs, various switching zones and full or partly colored mats are possible |
Original |
||
csa c22-2 250
Abstract: led white DOWNLIGHT UL1598 UL844 csa c22-2 junction box
|
Original |
rto-2w07-001rto-2w07-005rto-2w07-004rto-1001+10 | |
|
Contextual Info: Littelfuse Blade Terminal & Special Purpose Fuses Hazardous Area Fuses rohs| Barrier Network Fuse 242 Series • Meets Barrier Network Standards EN50020 for hazardous applications. • High interrupting rating. Meets the 1500A minimum. • Available in both axial lead and surface mount. |
OCR Scan |
en50020250vaca/dc635mm | |
|
Contextual Info: 440 / 450 Electronic Vibration Switches Datasheet OVERVIEW Metrix 440 and 450 electronic vibration switches provide economical, self-contained, single-channel vibration protection. The 440 switch is suitable for use in non-hazardous as well as Class I Div 2 hazardous areas. The 450 switch utilizes the same internal |
Original |
||
BA507C
Abstract: BA307B Ex-96 EX96D BA307C square root extractor application BA507
|
OCR Scan |
ba307c4/20maba307b4/20m+5 | |
MTL7787
Abstract: MTL 7787 MTL7700 mtl zener diode safety barrier MTL*787 hazardous area MA93 AS5V
|
Original |
mtl7787mtl7700mtl 7787mtl zener diode safety barrier+4 | |
MTL5041
Abstract: 93mA
|
Original |
mtl50414/20ma93ma | |
digital ohmmeter circuit diagramContextual Info: Intrinsically Safe Outputs Made Easy Part 5 of this series explains how to make solenoid valves, LED’s, and I/P transducers intrinsically safe. HAZARDOUS SIDE CLASS I, II, III DIVISION 1 GROUPS A-G NON-HAZARDOUS SIDE + 24 V + + + Digital Output D/O Solenoid |
Original |
z-148digital ohmmeter circuit diagram | |
|
|
|||
7c471
Abstract: westinghouse MCP *7C471 CROUSE-HINDS ECD bus duct UL857 dry transformers 15 KVA nema 4x stainless steel Cutler-Hammer contactor westinghouse breaker bracing wire
|
Original |
sys19crmain06-0467-27c-46766008com+11 | |
|
Contextual Info: IR2M Ex Mechanical Temperature-Controller for use in hazardous area Mechanical Controller Ex • Compact design • 4mm sensor diameter • 16A/230V switching capacity |
Original |
6a/230v122x120x90m20/m25 | |
IRE168DSContextual Info: IRE168DS Electronic Temperature Controller for use in non-hazardous Area. Electronic Controller non Ex • Compact Design • 4-20mA Output Process-Value • Multi-Voltage-Input |
Original |
ire168ds4-20ma69x85x6270x85x61mm+3 | |
1746-NT8
Abstract: 1746-OA16 manual 1746-A2 1746-NT8 wiring manual 1746-N2 1746A2 1746-IA16 1746-OA16 AD592CN ITS-90
|
Original |
1746-nt81746-in015b-en-p1746-oa16 manual1746-a2+7 | |
|
Contextual Info: IB2M Ex Mechanical fail-save protection Temperature Limiter for use in hazardous area Mechanical Controller Ex • Compact design • 4mm sensor diameter • 16A/230V switching capacity |
Original |
6a/230v122x120x90m20/m25 | |
TB 1237 ANContextual Info: IRB2M Ex Combination of Temperature-Controller and Limiter for use in hazardous area Mechanical Controller Ex • Compact design • 4mm sensor diameter • 16A/230V switching capacity |
Original |
6a/230vm20/m25220x120x90tb 1237 an | |
NDIR sensor circuit
Abstract: NDIR gas sensor IEC60079-0 IEC60079-11 A1A-IR15T electrochemical gas sensors EN6007911 sensor infrared methane gas sensor NDIR methane gas detector
|
Original |
ir15ttir15tt-mir25ttir25tt-m+10 | |
515-1049Contextual Info: Dialight ● ● ● ● ● ● ● ● Circuit Board Indicators Panel Mount Indicators Solid State Lighting 5151049 Traffic Signals Circuit Board Indicators Specifications Vehicle Lighting Rail LIGHT PIPE SINGLE ELEMENT Obstruction Lighting Hazardous Area |
Original |
515-1049 | |
thermal fuses color coding
Abstract: barrier network fuse axial thermal fuse 125OC 242 Series fuses color coding axial fuse color code
|
Original |
en50020jdyx2-10480125ocmil-std-202f+8 | |
fuses color coding axial type
Abstract: thermal fuses color coding fuse 242 125OC 242 Series axial fuse color code
|
Original |
en50020jdyx2-10480125ocmil-std-202f+7 | |