| telemecanique gv2 | Telemecanique GV2-M and K range with spring terminals References GV2-M motor circuit breakers References GV2-M013 GV2-M023 GV2-M033 GV2-M043 GV2-M053 GV2-M063 GV2-M073 Power (kW) 400/415V <0.06 0.06 0.09 0.12 0.25 0.37 0.75 Rating (A) 0.1 - 0.16 0.16 - 0.25 |
Original | ||||
| gv2-m | Curves TeSys protection components Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P Thermal-magnetic tripping curves for GV2-ME and GV2-P Average operating time at 20 °C according to multiples of the setting current Time (s) 10 000 1000 100 |
Original | ||||
| types gv2 | 3/02-03 Page 3 Monday, October 29, 2001 10:37 AM Presentation TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically |
Original | ||||
| Presentation TeSys protection components | Presentation TeSys protection components Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC 947-2 and IEC 947-4-1. |
Original | ||||
| gv2-me | Dimensions, mounting TeSys protection components Thermal-magnetic motor circuit-breakers types GV2-ME and GV2-P GV2-ME GV-AX GV-AD, AM, AN, AU, AS, AX GV-AE 15 = b 45 = 10 X1 Block GV-AD, AM, AN Block GV-AU, AS, AX 46 44,5 11 16 9,3 9,3 X1 15,7 18 81(1) 67,2 |
Original | ||||
| circuit-breakers | TeSys protection components References Magnetic motor circuit-breakers GV2 LE 534101 Magnetic motor circuit-breakers from 0.06 to 15 kW GV2 L: control by rocker lever, connection by screw clamp terminals Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 |
Original | ||||
| g | Motor circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-M References Thermal-magnetic motor circuit-breakers GV2-M Pushbutton control Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 220 400 230 V 415 V 440 V 500 V kW kW kW |
Original | ||||
| gv2-m | Characteristics TeSys protection components Thermal-magnetic motor circuit-breakers Environment Circuit-breaker type GV2-ME Conforming to standards EN 60947-1, 947-2, 947-4-1, EN 60204, UL 508, CSA C22-2 n° 14, NF C 63-650, 63-120, 79-130, VDE 0113, 0660 |
Original | ||||
| schneider | Chapter 3: Contents Schneider Electric TeSys motor circuit-breakers Selection guide: Thermal-magnetic motor circuit-breakers pages 3/2 and 3/3 Selection guide: Magnetic motor circuit-breakers pages 3/4 and 3/5 Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 |
Original | ||||
| Variable speed drives Altivar 32 For 3-phase | Variable speed drives Altivar 32 For 3-phase motors from 0.18 to 15 kW Catalogue April 2010 All technical information about products listed in this catalogue are now available on: www.schneider-electric.com Browse the “product data sheet” to check out: |
Original | ||||
| s0556-en | 1 2 3 4 5 6 7 8 9 10 5/0 version: 1.0 S0556-EN_Ver1.0.indd Content chapter 5 Safety control and protection solutions Mini-VARIO and VARIO switch disconnectors Selection guide: Mini-VARIO and VARIO switch disconnectors… 5/2 1 Mini-VARIO switch disconnectors |
Original | ||||
| TeSys Model U Selection guide Starter-controllers | TeSys Model U Selection guide Starter-controllers Function performed Function not performed Selectable overload class Detection of overtorque, no-load running, long starting times Earth fault protection (equipment protection only) Protection against phase imbalance |
Original | ||||
| TeSys Model U Curves Starter-controllers Tripping | TeSys Model U Curves Starter-controllers Tripping curves for control units LUCA, LUCB, LUCD Time (s) Average operating times at 20 ˚C according to multiples of the setting current, tolerance : ± 20 %. 1000 1 100 2 3 10 1 0,1 1 2 3 4 5 6 7 8 10 12 14 20 30 |
Original | ||||
| altivar 31 | Presentation Variable speed drives for asynchronous motors 2 Altivar 31 ESC ENT stop reset FWO REV 3 2 RUN 4 1 5 6 7 2 Presentation (continued) Variable speed drives for asynchronous motors 2 Altivar 31 Applications The Altivar 31 drive is a frequency inverter for 3-phase squirrel cage asynchronous |
Original | ||||
|
|
||||||
| Soft starters ATS 01 Catalogue May 07 General | Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3 |
Original | ||||
| 1389-2012.qxp:QuarkCatalogTempNew 9/5/12 3:00 PM | 1389-2012.qxp:QuarkCatalogTempNew 9/5/12 3:00 PM Page 1389 15 Motor Drive Controllers and Accessories RoHS ᭤ Two LEDs to Indicate “Power-ON” and Motor “Up-to-Speed” (Full Voltage) Selectable Kickstart for “Hard-to-Start” Loads |
Original | ||||
| variable speed drives | Variable speed drives for asynchronous motors Altivar 11 Catalogue July at a reduced size!… VVDED202051EN 2002 Real efficiency Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 92506 Rueil-Malmaison Cedex ART. 038998 http://www.schneider-electric.com |
Original | ||||
| tda7801 | TDA7801 Digital input quad power amplifier with built-in diagnostics features Features ■ Integrated 110 dB D/A conversion ■ I2S digital input (3.3/1.8 V) with TDM option '!0'03 PowerSO36 (slug-up) ■ Selectable input sampling frequency: 44.1 kHz, 48 kHz, 96 kHz, 192 kHz |
Original | ||||
| tda7801 | TDA7801 Digital input quad power amplifier with built-in diagnostics features Features ■ Integrated 110 dB D/A conversion ■ I2S digital input (3.3/1.8 V) with TDM option ■ Selectable input sampling frequency: 44.1 kHz, 48 kHz, 96 kHz, 192 kHz ■ MOSFET power outputs |
Original | ||||
| tda7801 | TDA7801 Digital input quad power amplifier with built-in diagnostics features Datasheet − production data Features ■ Integrated 110 dB D/A conversion ■ I2S digital input (3.3/1.8 V) with TDM option '!0'03 PowerSO36 (slug-up) ■ Selectable input sampling frequency: |
Original | ||||
| tda7801 | TDA7801 Digital input quad power amplifier with built-in diagnostics features Datasheet - production data Two I2C bus addresses and 8-ch TDM mode (only in PowerSO package) Optional non I2C bus mode Offset detector (play or mute mode) '!0'03 |
Original | ||||
| tda7801 | TDA7801 Digital input quad power amplifier with built-in diagnostics features Datasheet - production data Two I2C bus addresses and 8-ch TDM mode (only in PowerSO package) Optional non I2C bus mode Offset detector (play or mute mode) '!0'03 |
Original | ||||
| TeSys protection components Presentation, | TeSys protection components Presentation, description 3-pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively long starting times, |
Original | ||||
| Motor control 1 TeSys range provide you more | Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify |
Original | ||||
| tda780 | TDA7802 High efficiency digital input quad power amplifier with built-in diagnostics features, ’start stop’ compatible Datasheet - production data Description '!0'03 PowerSO36 The TDA7802 is a single chip quad bridge amplifier integrating a full D/A converter and |