FLUKE 8840A Search Results
Documents mentioning FLUKE 8840A
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 8840a | DIGITAL MULTIMETER Instruction Manual FLUKE. 8840A DIGITAL MULTIMETER Instruction Manual PN 879304 December 1991 Rev. 2, 4/94 ©1994 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies FLUKE |
OCR Scan | ||||
| 8840a | G E T T I N G A Guide for New Users 8840A/ 8842A G E T T I N G P/N 879291 DECEMBER 1991 ©1993 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies S T A R T E D A Guide for New Users 8840A/ |
OCR Scan | ||||
| The Model 2000 6½-Digit Multimeter is part of | The Model 2000 6½-Digit Multimeter is part of Keithley’s family of high performance DMMs. Based on the same high speed, low noise A/D converter technology as the Model 2001 and 2002, the 2000 is a fast, accurate, and highly stable instrument that’s as easy to operate as it is |
Original | ||||
| DATE SYM REVISION RECORD 8/31 / 9 9 - ISSUED | DATE SYM REVISION RECORD 8/31 / 9 9 - ISSUED AUTH, DR, CK, NT DG I- 0 0 , 042 i- 00, 58 i- 00, 055 :e i i __çfcâL 1 w HH 00, 33 T " 48 ---- 3, 95 !» te FIRST END: NYLON INSULATED MINIATURE TEST PROBE WITH EXTENDABLE TIP UP TO 3 ” KYNAR INSULATED STAINLESS STEEL TIP |
OCR Scan | ||||
DATE SYM R E V IS IO N 8/31 /9 9 - AUTH, DR, CK, RECORD ISSUED NT DG FIRST END: NYLON INSULATED MINIATURE TEST PROBENICKEL PLATED BRASS TIP NYLON INSULATION SECOND END: SHEATHED BANANA PLUG: NICKEL PLATED BRASS BODY BERYLLIUM COPPER SPRING POLYPROPYLENE INSULATION |
OCR Scan | |||||
DATE SYM REVISION RECORD 8/24/99 - ISSUED AUTH, DR, CK, NT DG 48* E FIRST END: SAFETY HOOKGOLD PLATED BERYLLIUM COPPER CONTACT POLYCARBONATE INSULATION 3 SECOND END: SHEATHED BANANA PLUG: NICKEL PLATED BRASS BODY BERYLLIUM COPPER SPRING POLYPROPYLENE INSULATION |
OCR Scan | |||||
| 3440 | Page 1 of 4, Document #4301 H HP 34401A Multimeter Uncompromising performance for benchtop and system testing Superior performance The HP 34401A multimeter gives you the performance you need for fast, accurate bench and systems testing. The HP 34401A provides a |
Original | ||||
| agilent 34401a | Agilent 34401A Multimeter Uncompromising Performance for Benchtop and System Testing Product Overview • Measure up to 1000 volts with 6 1/2 digits resolution • 0.0015% basic dcV accuracy (24 hour) • 0.06% basic acV accuracy (1 year) • 3 Hz to 300 kHz ac bandwidth |
Original | ||||
| agilent 34401a | Agilent 34401A Multimeter Uncompromising Performance for Benchtop and System Testing Data Sheet • Measure up to 1000 volts with 6 ½ digits resolution • 0.0015% basic dcV accuracy (24 hour) • 0.06% basic acV accuracy (1 year) • 3 Hz to 300 kHz ac bandwidth |
Original | ||||
| agilent 34401a | Agilent 34401A Multimeter Uncompromising Performance for Benchtop and System Testing Data Sheet • Measure up to 1000 volts with 6 ½ digits resolution • 0.0015% basic dcV accuracy (24 hour) • 0.06% basic acV accuracy (1 year) • 3 Hz to 300 kHz ac bandwidth |
Original | ||||
| xc4000 | Power Measurements: FLEX 10KA vs. XC4000 Devices T E C H N I C A L B R I E F 4 1 M A R C H 1 9 9 8 Many factors, such as supply voltage, current consumption, die size, and routing structure, affect semiconductor power consumption. For devices with the same supply voltages, the device current |
Original | ||||
| Agilent 34401A 6 ½ Digit Multimeter User’s Guide | Agilent 34401A 6 ½ Digit Multimeter User’s Guide Agilent Technologies Notices © Agilent Technologies, Inc. 1991 - 2007 Warranty No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation |
Original | ||||
| Power Consumption Comparison: APEX 20K vs. Virtex | Power Consumption Comparison: APEX 20K vs. Virtex Devices Technical Brief 57 October 1999, ver. 1 Introduction Altera Corporation 101 Innovation Drive San Jose, CA 95134 (408) 544-7000 http://www.altera.com https://websupport.altera.com Many factors, such as supply voltage, current consumption, die size, and routing structure, |
Original | ||||
| xc4000 | 消費電力の測定:FLEX 10KA vs. XC4000 TECHNICAL BRIEF 41 MARCH 1998 半導体デバイスの消費電力には、電源電圧、消費電流、ダイ・サイズ、配線構造などの多くの要素が影響を及ぼしま す。同じ電源電圧のデバイス間では、デバイスの消費する電流によって消費電力が決定されます。消費電力算出のた |
Original | ||||
|
|
||||||
| atf1500as | White Paper ATF1500AS Analysis Report Introduction ® The Altera MAX 7000 family has many features that make it a leader in the programmable logic industry. MAX 7000 devices consume minimal power and are reliable at high frequencies. Additionally, these devices were designed for optimum timing characteristics and to support in-system programmability |
Original | ||||
| AN770 S i826 X 5 K V I SOLATOR TEST R EPORT S | AN770 S i826 X 5 K V I SOLATOR TEST R EPORT S UMMARY 1. Introduction This application note summarizes various performance, quality, and reliability test results for the Si826x isolator family. A summary of tests and their results is listed in Table 1. For more details on a particular test, see the |
Original | ||||
| AN742 Si87 XX 5 K V I SOLATOR TEST R EPORT S | AN742 Si87 XX 5 K V I SOLATOR TEST R EPORT S UMMARY 1. Introduction This application note summarizes various performance, quality, and reliability test results for the Si87xx isolator family. A summary of tests and their results is listed in Table 1. For more details on a particular test, see the |
Original | ||||
| 消費電力の比較:APEX 20K vs. Virtex Technical Brief 57 | 消費電力の比較:APEX 20K vs. Virtex Technical Brief 57 October 1999, ver.1 イントロダクション Altera Corporation 101 Innovation Drive San Jose, CA 95134 (408)544-7000 http://www.altera.com https://websupport.altera.com 日本アルテラ株式会社 |
Original | ||||
| MINI.ALLIGATOR CLIPS TO BNC MALE MINI-CLIPS/BNC | MINI.ALLIGATOR CLIPS TO BNC MALE MINI-CLIPS/BNC MALE 1st END — (2) Plated steel alligator clips w ith vinyl in sulation, one red and one black. CABLE - RG58C/U. Molded Y-insulation. RGS8C/U Length 795-2605-25 795-2606-25 795-2607-25 795-2608-25 795-2609-25 |
OCR Scan | ||||
| Model 2000 Multimeter User’s Manual A GREATER | Model 2000 Multimeter User’s Manual A GREATER MEASURE OF CONFIDENCE WARRANTY Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 3 years from date of shipment. Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, |
Original | ||||
| an560 | AN560 Si84 X X 2.5 KV D IGITAL I SOLATOR TE S T R EPORT S UMMAR Y 1. Introduction This application note summarizes various performance, quality, and reliability test results for the Si84xx digital isolator family. A summary of tests and their results is listed in Table 1. For more details on a particular test, see the |
Original | ||||
| Discontinued and Superseded Stock Number History. | Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item. |
Original | ||||
| Discontinued and Superseded Stock Number History. | Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item. |
Original | ||||
| in | Discontinued and Superseded Stock Number History. This document contains Discontinued and Superseded Stock Number History. The information is listed in the following format: Stock Number: The original RS Stock Number of the item. Brief Description: The Invoice Description of the item. |
Original | ||||
| keithley | 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 www.keithley.com Visit us at www.TestEquipmentDepot.com research n nanotechnology n semiconductor n wireless n electronic components research n nanotechnology n semiconductor |
Original | ||||