FLAME DETE Search Results
Documents mentioning FLAME DETE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| uvisor | System 800xA for Power Generation UvisorTM FAU 810 – Flame Analysis Unit 800 Series Combustion Instruments Flexible and Reliable Device for use with all ABB Flame Detectors The Flame Analysis Unit, or FAU810, is ABB’s latest leading-edge flame analysis device. |
Original | ||||
| FLAME SENSOR UVTRON ® R9454, R9533 Quick | FLAME SENSOR UVTRON ® R9454, R9533 Quick Detection of Flame from Distance, Compact UV Sensor with High Sensitivity and Wide Directivity, Suitable for Flame Detectors and Fire Alarms. The UVTRON R9533 and R9454 are ultraviolet ON/OFF sensors that utilize the photoelectric effect from metal and gas multiplication. These |
Original | ||||
| flame sensor | FLAME SENSOR UVTRON ® R2868 Quick Detection of Flame from Distance, Compact UV Sensor with High Sensitivity and Wide Directivity, Suitable for Flame Detectors and Fire Alarms. Hamamatsu R2868 is a UVTRON ultraviolet ON/OFF detector that makes use of the photoelectric effect of metal and the gas |
Original | ||||
| flame sensor uv | FLAME SENSOR UV TRON® R2868 Quick Detection of Flame from Distance, Compact UV Sensor with High Sensitivity and Wide Directivity, Suitable for Flame Detectors and Fire Alarms. Hamamatsu R2868 is a UV TRON ultraviolet detector that makes use of the photoelectric effect of metal and the gas multiplication |
Original | ||||
| diode assembly | PHOTO IC Photo IC diode assembly S10108, S10109 For flame eye/using photo IC diode (RoHS compliance) instead of CdS cell S10108 and S10109 sensors are designed specifically for flame detection (flame eye) in oil-fired hot water boilers and heaters. These sensors incorporate a photo IC diode instead of conventional CdS cells and are available with 2 types of incident light direction (head-on |
Original | ||||
| r7749b | INSTRUCTIONS 9à (§ Honeywell R7749B Dynamic Ampli-check Ultraviolet Flame Amplifier APPLICATION T h e R 7 7 4 9 B D y n a m ic A m p li-c h e c k U ltra v io le t Amplifier is a solid state plug-in unit which responds to a flame detector signal and indicates the presence of flame |
OCR Scan | ||||
| 7204 | 3 Flame Retardant Label Materials 7203 • 7204 Technical Data January, 2008 Product Description 3M™ Flame Retardant Label Materials 7203 and 7204 are designed to meet FR requirements including UL-94-VTM-0. The polyester facestocks offer excellent electrical insulating performance for use in electronic applications where flame |
Original | ||||
| s10108 | PHOTO IC Photo IC diode assembly S10108, S10109 For flame eye/using photo IC diode (RoHS compliance) instead of CdS cell S10108 and S10109 sensors are designed specifically for flame detection (flame eye) in oil-fired hot water boilers and heaters. These sensors incorporate a photo IC diode instead of conventional CdS cells and are available with 2 types of incident light direction (head-on |
Original | ||||
| flame sensor | FLAME SENSOR UV TRON ® R9454, R9533 Quick Detection of Flame from Distance, Compact UV Sensor with High Sensitivity and Wide Directivity, Suitable for Flame Detectors and Fire Alarms. The UV TRON R9533 and R9454 are UV sensors that utilize the photoelectric effect from metal and gas multiplication. These devices are sensitive only to UV light in a spectral range of 185 nm to 260 nm. This makes |
Original | ||||
| flame detector | 7 786 Burner Controls LGI16… Burner controls • For use on industrial furnaces • For burners in continuous operation • Without fan control and air pressure supervision • Flame supervision - with QRA53… / QRA55…, flame detector - with ionizations probe |
Original | ||||
| mm1217 | Flame Detection Amplifier MM1217 MITSUMI Flame Detection Amplifier Monolithic IC MM1217 Outline This IC is comprised of an operation amplifier, a comparator, and a reference power source. It is worthy of note that the input offset voltage and the input offset voltage temperature drift of this operation amplifier are |
Original | ||||
| r7748b | IN S TR U C TIO N S TO Honeywell (§ R7748B Dynamic Ampli-check Infrared Flame Amplifier APPLICATION The R7748B Dynamic Am pli-check Infrared Am plifier is a solid state plug-in unit which responds to aflam e detector signal and indicates the presence of flame when used with |
OCR Scan | ||||
| mm1217 | Flame Detection Amplifier MM1217 MITSUMI Flame Detection Amplifier Monolithic IC MM1217 Outline This IC is comprised of an operation amplifier, a comparator, and a reference power source. It is worthy of note that the input offset voltage and the input offset voltage temperature drift of this operation amplifier are |
Original | ||||
| PRODUCT NEWS Environmentally-sound tantalum chip | PRODUCT NEWS Environmentally-sound tantalum chip capacitors E/SV Series Lead-free terminal and Halogen-free resin package Molded resin package Included halogen (bromine) as flame retardant Changed into halogen-free/antimony-free flame retardant Tarminal plating |
Original | ||||
|
|
||||||
| YAGEO CORPORATION LEADED RESISTORS FLAME-PROOF | YAGEO CORPORATION LEADED RESISTORS FLAME-PROOF TYPE Metal Film Resistors Normal & Miniature Style [ FMF Series ] FEATURES Flame-Proof Coating UL-1412 Power Rating 1/4W, 1/2W, 1W, 2W Resistance Tolerance ± 1% T.C.R. ± 50ppm/ºC, ± 100ppm/ºC DERATING CURVE |
Original | ||||