FERRAZ SHAWMUT ATDR Search Results
FERRAZ SHAWMUT ATDR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| CS-SATDRIVEX2-002 | Amphenol Cables on Demand | Amphenol CS-SATDRIVEX2-002 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 2m | |||
| CS-SATDRIVEX2-000.5 | Amphenol Cables on Demand | Amphenol CS-SATDRIVEX2-000.5 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 0.5m | |||
| CS-SATDRIVEX2-001 | Amphenol Cables on Demand | Amphenol CS-SATDRIVEX2-001 Serial ATA Extension Cable - SATA II Drive Extension Cable with Power (6.0 Gbps) 1m | |||
| SN74LV138ATDR | Texas Instruments | 3-Line To 8-Line Decoder/Demultiplexers 16-SOIC -40 to 125 |
|
|
|
| SN74LV4053ATDRQ1 | Texas Instruments | Automotive Catalog Triple 2-Channel Analog Multiplexer/Demultiplexer 16-SOIC -40 to 105 |
|
|
Documents mentioning FERRAZ SHAWMUT ATDR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ferraz | UltraSafeTM Fuse Module (USFM) Smallest Footprint in the Industry Motor control protection achieves greater efficiency, productivity and safety with Ferraz Shawmut’s UltraSafeTM Fuse Modules (USFM) “A great feature is the small 45mm footprint…” |
Original | ||||
| ferraz shawmut | Power Electronics Solutions The relentless pursuit of electrical protection for power electronics. Serving companies that manufacture: • Drives • Induction heating • Inverters • Motor controllers • Rectifiers • UPS • Welding equipment Ferraz Shawmut brings the relentless pursuit |
Original | ||||
| socomec | SOCOMEC FUSERBLOC FUSIBLE DISCONNECT SWITCHES Ferraz Shawmut FUSERBLOC disconnect switches are extremely durable, manually operated, fusible disconnect switches. The switches employ double break contacts per pole that ensure complete isolation of the fuse when the switch is in the |
Original | ||||
| power distribution block | Finger-Safe Power Distribution Blocks Solutions for Safer Panels Building on our revolutionary ULTRASAFE™ fuse holders, we’ve expanded the safety concept into a line of power distribution blocks — Ferraz Shawmut’s Finger-Safe Power Distribution Blocks (FSPDB). The features |
Original | ||||
| ferraz shawmut | ULTRASAFE™ Fuse Holders The safety evolution continues. The Revolutionary Advantages Ferraz Shawmut continues to lead the safety evolution with even more improvements to our popular ULTRASAFE fuse holders. Renowned throughout the industry for their forward-thinking design, ULTRASAFE fuse holders deliver |
Original | ||||
| ferraz | DFC SERIES DEAD-FRONT FUSE COVERS DFC DEAD-FRONT FUSE COVERS Ferraz Shawmut DFC Dead-Front Fuse Covers snap on to individual fuses installed in fuse blocks, covering exposed live clips and terminals and reducing accidental contact by personnel. They are sized to fit |
Original | ||||
| ferraz shawmut | USFM 600 VOLT/ULTRASAFE™ FUSE MODULES ULTRASAFE FUSE MODULES Ferraz Shawmut ULTRASAFE™ Fuse Modules have a unique, compact design suited for use with 45mm wide IEC contactors. These modules also offer other features not found on other Class CC and midget Ultrasafe fuse holders such as an |
Original | ||||
| ferraz shawmut | GPM SERIES PANEL MOUNT/FUSE HOLDERS GPM PANEL MOUNT FUSE HOLDERS Ferraz Shawmut GPM Panel Mount Fuse Holders are in sizes to accommodate Class CC and Midget (1-1/2” x 13/32”) fuses. All 30A holders have glassfilled thermoplastic insulators for extra dependability |
Original | ||||
| Gears & Fuse Gears Gears & Fuse Gears American | Gears & Fuse Gears Gears & Fuse Gears American General Purpose Fuses Cylindrical & Blade Fuse Blocks In-Line FEB/FEC/FEX/FEY 600 VOLTS Ferraz Shawmut’s complete line of single and dual pole in-line fuse holders accommodate either 1-1/2" x 13/32" (10x38mm) midget or Class CC fuses. The fuse holders are |
Original | ||||
| ferraz shawmut | Ferraz Shawmut SCCR Quick Select Guide ITEM 1MSC 1SC 20300 - 22053R TYPE DESCRIPTION Form 101 Modular Semiconductor Fuse Blocks Form 101 Modular Semiconductor Fuse Blocks 250V Open Style Fuseholder for Class H, K and R Fuses H For use with Class H K For use with Class K |
Original | ||||
| uscc | USCC & USM uLTRASAFE FUSEHOLDERS TM ULTRASAFE MODULAR FUSE HOLDERS Ferraz Shawmut UltraSafe™Modular Fuse Holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2” x 13/32” (USM) AC and DC-rated fuses up to 30 amperes. UltraSafe holders qualify as “finger |
Original | ||||
| GPM SERIES PANEL MOUNT / FUSE HOLDERS GPM PANEL | GPM SERIES PANEL MOUNT / FUSE HOLDERS GPM PANEL MOUNT FUSE HOLDERS Ferraz Shawmut GPM Panel Mount Fuse Holders are in sizes to accommodate 5mm x 20mm, 1/4” x 1-1/4”, Class CC and Midget (1-1/2” x 13/32”) fuses. All 30A holders have glass-filled polyester |
Original | ||||
| midget | MIDGET & CLASS CC 600 VOLT / FUSE BLOCKS 600 VOLT MIDGET AND CLASS CC FUSE BLOCKS Ferraz Shawmut Midget Fuse Blocks accommodate all 30 ampere 1-1/2” x 13/32” midget fuses. Class CC Fuse Blocks accommodate all 30 ampere Class CC fuses. A choice of box, screw, or pressure-plate |
Original | ||||
| ferraz shawmut | USCC & USM TM 24, 48 & 600 VOLT / ULTRASAFE FUSEHOLDERS ULTRASAFE MODULAR FUSE HOLDERS Ferraz Shawmut ULTRASAFETM modular 24, 48 and 600 volt Fuse Holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2" x 13/32" (USM) as well as DC rated fuses up to 30 |
Original | ||||
|
|
||||||
Allen Bradley NEMA Motor Starters and Ferraz Shawmut Fuses Type 2 Protection Achieving Type 2 “No Damage” Motor Start Protection Type 2 “No Damage” Protection - What Is It and Which Fuses Are Best? Type 2 protection, also referred to as “no damage” protection, simply means that if a short circuit occurs, the short circuit protective device |
Original | |||||
| USCC & USM TM 24, 48 & 600 VOLT / ULTRASAFE | USCC & USM TM 24, 48 & 600 VOLT / ULTRASAFE FUSEHOLDERS ULTRASAFE MODULAR FUSE HOLDERS Ferraz Shawmut ULTRASAFETM modular 24, 48 and 600 volt Fuse Holders introduce a new level of safety for Class CC (USCC) and Midget 1-1/2” x 13/32” (USM) as well as DC rated fuses up to 30 |
Original | ||||
| us.ferrazshawmut.com Upgrade to A4BQ, 600V, CLASS | us.ferrazshawmut.com Upgrade to A4BQ, 600V, CLASS L CHART CL CLL A4BY CLU KLLU KLP-C WCL KLU A4BQ (amp) 600V NCL KRP-C KRPC-L (OVER 600A) LCL LCU Ampere Rating 100 - 800 801 - 1200 1201 - 1600 1601 - 2000 2001 - 2500 2501 - 3000 3001 - 4000 4001 - 5000 5001 - 6000 |
Original | ||||
| Amp-Trap 2000® Your electrical system is your | Amp-Trap 2000® Your electrical system is your lifeline. A lifeline that can be cut by an arc flash can disintegrate. Conductors can vaporize. Bus bars can break. And components like switchgear, MCC buckets and motor starters can be destroyed, bringing your operation to a halt. |
Original | ||||
| Overcurrent and Overvoltage Protection Changes in | Overcurrent and Overvoltage Protection Changes in the 2008 NEC® Code Overcurrent and Overvoltage Protection Changes in the 2008 Code Contents 1. Short Circuit Current Ratings are Clarified…3 |
Original | ||||
| Selective Coordination Panel Meeting the Demands | Selective Coordination Panel Meeting the Demands of the New 2008 NEC® Code Market Requirements Due to recent NEC® changes (implemented in the 2005 code cycle and refined in the 2008 code cycle), a requirement to provide selective coordination emerged in a number of critical |
Original | ||||
| Tech Topics: Component Protection Note 2, Issue 1 | Tech Topics: Component Protection Note 2, Issue 1 Enhancing Short Circuit Safety with Type 2 Coordination for Motor Starters Michael J. Lang Field Engineering Manager Introduction As of April 26, 2006, suppliers of UL listed Industrial Control Panels (ICP) must clearly label |
Original | ||||
| allen-bradley starter | SCCR Comparison Table, Circuit Breakers vs. USFM ABB Starter Continuous Ampere Rating A9, A12, A16, A26 + TA25 9, 12, 16, 25 Allen-Bradley Starter Continuous Ampere Rating ABB Breaker S3L…MW S3L…TW T2H…TW T2H…TW Combination Voltage Allen-Bradley Breaker |
Original | ||||
| Tech Topics: Selective Coordination Note 1 , | Tech Topics: Selective Coordination Note 1 , Issue 1 Evaluating Selective Coordination Between Current-Limiting Fuses And Non Current-Limiting Circuit Breakers Steve Hansen Senior Field Engineer Robert Lyons Jr. Product Manager Introduction System downtime is reduced when overcurrent protective devices are selectively coordinated. |
Original | ||||
| Product Guide Product Guide Amp-Trap 2000® Fuses | Product Guide Product Guide Amp-Trap 2000® Fuses AJT A2D & A6D A4BQ ATDR & ATQR Class J Time Delay 1 to 600A 600V AC, 200kA I.R. 300kA I.R. UL Witnessed 500V DC, 100kA I.R. Current Limiting UL Listed CSA Certified Smart Spot Indicator Motor, motor controller, control |
Original | ||||
| Fuses – Fusegear Semiconductor Protection Fuses • | Fuses – Fusegear Semiconductor Protection Fuses • Protistor Mapping 70 - 71 • American Round Fuses - Form 101 range 72 - 81 • Other American Round Fuses 82 • Ferrule-style Protistor fuses 83 - 87 • Protistor DIN standard fuses sizes 000-00 88 - 89 |
Original | ||||