Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    FC11AL2 Search Results

    FC11AL2 Datasheets (1)

    United Automation
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    FC11AL2
    United Automation UNIVERSAL PHASE ANGLE CONTROLLER C/W INTEGRAL POWER DEVICE Original PDF 178.85KB 2
    SF Impression Pixel

    FC11AL2 Price and Stock

    United Automation Inc

    United Automation Inc FC11AL/2

    Power Controller; |United Automation FC11AL/2
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark FC11AL/2 Bulk 8 1
    • 1 $147.73
    • 10 $129.95
    • 100 $107.27
    • 1000 $107.27
    • 10000 $107.27
    Buy Now

    Documents mentioning FC11AL2

    Document Partial File Text Tags Type PDF
    x10203
    lA CSR CSR/604/1004/1504 POWER REGULATOR CHIP X10203 UNITED AUTOMATION LTD. INTRODUCTION The CSR Power Regulator chip is a compact and robust unit which is capable of controlling single-phase mains driven loads of up to 15 amps. Used in conjunction with a variable resistance (potentiometer), the chip gives a fully adjustable
    OCR Scan PDF
    united automation
    r. UNITED AUTOMATION LTD CSR2-SERIES CSR2 POWER REGULATORS X10282 INTRODUCTION The CSR Power Regulators are compact and robust units which are capable of controlling single-phase main* driven loads of up to ISA. The CSR2 - series regulators come in two styles, open (type B) and enclosed (type EX with the enclosed version having its own
    OCR Scan PDF
    x10229
    RFI SUPPRESSION FOR SINGLE PHASE + POWER REGULATORS RFI X10229 INTRODUCTION Phase-angle power controllers generate Radio Frequency Interference (RFI) when the power is switched on during each half-cycle of the mains wave form. In sensitive applications this
    Original PDF
    x10229
    RFI SUPPRESSION FOR SINGLE PHASE + POWER REGULATORS RFI X10229 INTRODUCTION Phase-angle power controllers generate Radio Frequency Interference (RFI) when the power is switched on during each half-cycle of the mains wave form. In sensitive applications this
    Original PDF
    x10229
    RFI SUPPRESSION FOR SINGLE PHASE POWER REGULATORS RFI X10229 INTRODUCTION Phase-angle power controllers generate Radio Frequency Interference (RFI) when the power is switched on during each half-cycle of the mains waveform. In sensitive applications this interference, or interaction with other
    Original PDF
    x10229
    F-SERIES RFI SUPPRESSION FOR SINGLE PHASE POWER REGULATORS F-RFI X10229 INTRODUCTION Phase-angle power controllers generate Radio Frequency Interference (RFI) during each half-cycle of the mains waveform when the power is switched on. In sensitive applications this interference, or interaction with other
    Original PDF