Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ELECTRICAL CALCULATION FOR TRANSFORMER Search Results

    ELECTRICAL CALCULATION FOR TRANSFORMER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SF-SFP28LPB1W-0DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-0DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 0dB Attenuation & 1W Power Consumption PDF
    SF-SFPPLOOPBK-0DB
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-0DB SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 0dB Attenuation & 0W Power Consumption PDF
    SF-SFPPLOOPBK-003.5
    Amphenol Cables on Demand Amphenol SF-SFPPLOOPBK-003.5 SFP+ Loopback Adapter Module for SFP+ Port Compliance Testing - 3.5dB Copper/Optical Cable Emulation PDF
    SF-SFP28LPB1W-3DB
    Amphenol Cables on Demand Amphenol SF-SFP28LPB1W-3DB SFP28 Loopback Adapter Module for SFP28 Port Compliance Testing - 3dB Attenuation & 1W Power Consumption PDF
    SF-100GLB1.5W-6DB
    Amphenol Cables on Demand Amphenol SF-100GLB1.5W-6DB QSFP 100G Loopback Adapter Module for QSFP28 Port Testing - 6dB Attenuation & 1.5W Power Consumption [100-Gigabit Ethernet Ready] PDF

    Documents mentioning ELECTRICAL CALCULATION FOR TRANSFORMER

    Document Partial File Text Tags Type PDF
    b66395
    ETD 54/28/19 Core B66395 27,8 _ 0,4 19,8+0,8 ■ In accordance with IEC 61185 ■ For SMPS transformers with optimum weight/performance ratio at small volume ■ ETD cores are supplied as single units Magnetic characteristics (per set) = 0,45 mm–1 = 127 mm
    Original PDF
    etd 39
    ETD 39/20/13 Core B66363 20 _ 0,4 CECC 25 301-002 (material N27) ■ For SMPS transformers with optimum weight/performance ratio at small volume 14,2+0,8 g ■ In accordance with IEC 61185 ■ Quality assurance per UTE 83313-002/ ■ ETD cores are supplied as single units
    Original PDF
    b66421
    EFD 25/13/9 Core B66421 ■ E core with flattened, lower center leg for especially flat transformer design ■ For DC/DC converters ■ EFD cores are supplied as single units Magnetic characteristics (per set) Σl/A le Ae A min Ve = 0,98 mm–1 = 57 mm = 58 mm2
    Original PDF
    etd 59
    ETD 59/31/22 B66397 31,2 _ 0,4 ■ In accordance with IEC 61185 ■ For SMPS transformers with optimum weight/performance ratio at small volume ■ ETD cores are supplied as single units 22+0,9 Core Magnetic characteristics (per set) = 0,38 mm–1 = 139 mm
    Original PDF
    b66423
    EFD 30/15/9 Core B66423 ■ E core with flattened, lower center leg for especially flat transformer design ■ For DC/DC converters ■ EFD cores are supplied as single units Magnetic characteristics (per set) Σl/A le Ae A min Ve = 0,99 mm–1 = 68 mm = 69 mm2
    Original PDF
    etd 49
    ETD 49/25/16 Core B66367 24,9 _ 0,4 17,7+0,8 g ■ In accordance with IEC 61185 ■ Quality assurance per UTE 83313-004/ CECC 25 301-004 (material N27) ■ For SMPS transformers with optimum weight/performance ratio at small volume ■ ETD cores are supplied as single units
    Original PDF
    LOW PROFILE SELF-LEADED SMT DUAL INDUCTORS
    LOW PROFILE SELF-LEADED SMT DUAL INDUCTORS Materials meet UL 94V-0 rating Frequency range of up to 1 MHz Can be used as a simple inductor, 1:1 coupled inductor, or 1:1 transformer Electrical Specifications @ 25°C — Operating Temperature -30°C to +130°C
    Original PDF
    b66358
    ETD 29/16/10 Core B66358 ETD 29/16/10 through ETD 59/31/22 16 _ 0,4 10,7+0,6 g ■ In accordance with IEC 61185 ■ For SMPS transformers with optimum weight/performance ratio at small volume ■ ETD cores are supplied as single units Magnetic characteristics (per set)
    Original PDF
    E 13/7/4 (EF 12,6) Core B66305 ■ In accordance
    E 13/7/4 (EF 12,6) Core B66305 ■ In accordance with IEC 61246 For miniature transformers Available with SMD coil former E cores with high permeability for common-mode chokes and broadband applications ■ E cores are supplied as single units
    Original PDF
    b66361
    ETD 34/17/11 Core B66361 CECC 25 301-001 (material N27) ■ For SMPS transformers with optimum weight/performance ratio at small volume 11,8+0,6 17,5 _ 0,4 g ■ In accordance with IEC 61185 ■ Quality assurance per UTE 83313-001/ ■ ETD cores are supplied as single units
    Original PDF
    stpm11
    STPM11, STPM12 STPM13, STPM14 Single phase energy metering IC with pulsed output and digital calibration Features ■ Ripple free active energy pulsed output ■ Direct stepper counter drivers ■ Shunt, current transformer, Rogowsky coil sensors ■ Live and neutral monitoring (STPM13/14)
    Original PDF
    STPM11/12/13/14 Single phase energy metering IC
    STPM11/12/13/14 Single phase energy metering IC with pulsed output and digital calibration Features ■ Ripple free active energy pulsed output ■ Direct stepper counter drivers ■ Shunt, current transformer, Rogowsky coil sensors ■ Live and neutral monitoring (STPM13/14)
    Original PDF
    stpm11
    STPM11, STPM12 STPM13, STPM14 Single phase energy metering IC with pulsed output and digital calibration Features ■ Ripple free active energy pulsed output ■ Direct stepper counter drivers ■ Shunt, current transformer, Rogowsky coil sensors ■ Live and neutral monitoring (STPM13/14)
    Original PDF
    LLC Resonance Power Transformers SRX Series
    LLC Resonance Power Transformers SRX Series Contents Page Development Concept…1 Replacement Parts List…2 SRX45EM (Height from the board: 8mm)…4
    Original PDF
    sames SA9105 APPLICATION NOTE PM9105AF THREE
    sames SA9105 APPLICATION NOTE PM9105AF THREE PHASE POWER/ENERGY METERING MODULE PULSE OUTPUT FEATURES n Performs one, two or three phase power and energy measurement n Uses current transformers for current sensing n Meets the accuracy requirements for Class 1 AC Watt hour meters
    Original PDF
    bellcore
    Document 234 F-I-T Calculation DO/DT/DS Series Surface Mount Inductors The Steady State Failure Rate is Calculated Per Bellcore TR - 332 to be: λSS = λG π Q π S π T = 38 failures per billion hours Where: λG = 19 (From Bellcore TR - 332 Table A for Categories " Power Transformer" and " Power FilterCoil" )
    Original PDF
    bellcore
    Document 236 F-I-T Calculation TTWB Series Wideband Transformers The Failure Rate is calculated per Bellcore TR-322 (( )) ( ) λHIC = Σ λGπ Qπ S π T + ( N I λI + N C λC )(π F ) = 38 Failures per billion hours Where: λG = 19 (From Bellcore TR-322 Table A: Power Transformer / Power FilterCoil)
    Original PDF
    bellcore
    Document 237 F-I-T Calculation WB Series Wideband Transformers The Failure Rate is calculated per Bellcore TR-322 (( )) ( ) λHIC = Σ λGπ Qπ S π T + ( N I λI + N C λC )(π F ) = 38 Failures per billion hours Where: λG = 19 (From Bellcore TR-322 Table A: Power Transformer / Power FilterCoil)
    Original PDF
    llc resonance
    LLC Resonance Power Transformers Pin terminal type SRX series Type: SRX45EM(Drop-in) SRX38EM(Drop-in) SRX43EM(Drop-in/Through hole) SRX30ER(Through hole) SRX35ER(Through hole) SRX38ER(Through hole) SRX48EM(Through hole) SRX40ER(Through hole) Issue date: April 2010
    Original PDF
    stpm11
    STPM11/12/13/14 Single phase energy metering IC with pulsed output and digital calibration Feature summary ■ Ripple free active energy pulsed output ■ Direct stepper counter drivers ■ Shunt, current transformer, Rogowsky coil sensors ■ Live and neutral monitoring (STPM13/14)
    Original PDF
    distribution transformers
    Power and Distribution Transformers Australian Catalogue 2014 Increase Power Availability Enhance Safety Solutions for the Mining Industry Global Transformer Capabilities Schneider Electric has a large network of transformer manufacturing plants around the world,
    Original PDF