DIRECTIONAL STATIC OVERCURRENT RELAY Search Results
DIRECTIONAL STATIC OVERCURRENT RELAY Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-SFPP2EPASS-000.5 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-000.5 0.5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (1.6 ft) | |||
| SF-SFPP2EPASS-001 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-001 1m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (3.3 ft) | |||
| SF-SFPP2EPASS-003 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-003 3m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (9.8 ft) | |||
| SF-SFPP2EPASS-005 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-005 5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (16.4 ft) | |||
| SF-SFPP2EPASS-007 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-007 7m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (23 ft) |
Documents mentioning DIRECTIONAL STATIC OVERCURRENT RELAY
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| rxpe 40 | ABB ASEA BROWN BOVERI Type RXPE 40 0° directional overcurrent relay — B03-3013 if * ' Page 1 January 1989 Changed since January 1987 Data subiect to change without notice ABB Relays Abstract Application • Voltage-polarized • Angle of maximum sensitivity: |
OCR Scan | ||||
| racib | ¡¡k a# as m iv ASEA B R O W N BO VER I ABB Relays ------------------- _ ------------------------------- - Type RACIB F e e d e r p r o te c tio n w ith a u to |*0 q lo s in g B03-7211E SU^6Ctt0c^an9ew'^out notice RACIB Abstract Application • Three-phase time-overcurrent relay with |
OCR Scan | ||||
| overcurrent relay | A llli Type RXPE 41/40 W W W -9 0 ° or 0° directional overcurrent relay ASEA B R O W N BO V ER I w w w " w w w m w B03-3010 p ìe ! 1 J une 3 0. 1982 D a ta s ubject to c h a n g e without notice « ABB Relays o Abstract Voltage-polarized Angle of maximum sensitivity: |
OCR Scan | ||||
| racic | II li filili ih ASEA B R O W N BOVERI ABB Relays Type RACIC B03-2313E F©6d©r rccucI Changed since January 1985 DrOtGCtiOn piUlCl/llUII January 1 9 8 7 D a ta s ubject to c h a n g e without noti« Abstract Application • Two-phase or three-phase time-overcurrent |
OCR Scan | ||||
| 1M DB06006-EN Page 1 March 1992 Changed since | 1M DB06006-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (832610) Features A p plica tion •T h ree -p ha se and earth, three-zone sequen tial m easurem ent distance relay fo r over |
OCR Scan | ||||
| rxpe 42 | a mm* m ASEA B R O W N BO VERI ABB Relays Abstract *s Application Type RXPE 42 —30° directional overcurrent relay Voltage-polarized Operating value constant within a wide po larizing voltage range Angle of maximum sensitivity 30°, current leading voltage; sensitivity down to 0.15 % |
OCR Scan | ||||
| overcurrent relay | Directional time-overcurrent relays and protection assemblies based on single phase elements RXPDK 2H and RAPDK 1MRK 509 007-BEN Page 1 Issued April 1999 Changed since July 1998 Data subject to change without notice (SE970136) (SE970128) Features • Two- or three-phase directional overcurrent |
Original | ||||
| ralza | Imo-No. INFORMATION RF 619-001 From/Date ASS Relays Reg. RFA, No\'ember 1988 Edition 4 E Page 743.5 1 Ultra High SpeedLine Protection type RALZA Unaffected by current transformer voltage transformer transients. saturation and capacitor Ultra high Spe-edof fault detection, typical 2-5 ms. |
Original | ||||
| racib | A l i l i f * » I P RACIB 1MRK 507 001-BEN Feeder protection with automatic reclosing equipment Page 1 April 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (SE 84 09 60) Features • Three-phase time-overcurrent relay with start, |
OCR Scan | ||||
| razoa | ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se quential measurement distance relay for overhead lines and cables • Independent X and R reach settings |
OCR Scan | ||||
| rxpe | Il Hi II **I»IP ASEA B R O W N BOVERI ABB Relays Abstract Application RXPE 47 +65° directional-overcurrent relay B03-3012E Page 1 June 30, 1982 Data subject to change without notice • Voltage-polarized • Operating value constant within a wide polarizing voltage range |
OCR Scan | ||||
| b03-7016e | Ik Bill M U I! ASEA BROWN BOVERI A B B Relays Type RALZA B03-7016E C o m b in e d d ir e c t io n a l- w a v e a n d p h a s e a n d g ro u n d & ^ W i9 a 5 subject t0changewithout notice d is t a n c e b a c k u p r e la y f o r t r a n s m i s s i o n lin e s |
OCR Scan | ||||
| 4L M U INFORMATION M » ASE*BROWNBD^Éflr F ra m 'û | 4L M U INFORMATION M » ASE*BROWNBD^Éflr F ra m 'û a tB R F R , December 19S3 ABB Refays IjîFû'Nd. RK 511-300 E fie g . P ag« 5625 1 Edition i Directional relay type R X PE k o Single phase directional current relay using voltage reference o Different current ranges available for operate values from 3 nriA |
OCR Scan | ||||
|
|
||||||
| Modular multifunction generator protection RAGCX | Modular multifunction generator protection RAGCX 1MRK 502 007-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970186) Features • RAGCX is a modular generator protection that enables selection of the desired protection in a standardized package with or |
Original | ||||
| ragpc | J L li I I 1 lrlc"Nn RX 641-303 E INFORMATION iS E i BRO W N BCVERI F r o m /B a te <*09- RER, August 1973 ABB Refays E ditio n l F>age 7452 m * rk X' 00-90 Section 6 Loss-of-field relays type BAGPA and RAGPC for synchronous generators _____________ ______________________________ |
OCR Scan | ||||
| Types RALZA and RALZB ASEA BROWN BOVER! Combined | Types RALZA and RALZB ASEA BROWN BOVER! Combined directional-wave and impedance backup relay 1 -» - I n r- 1M DB06012-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection Features •Th ree directional-wave detecting modes |
OCR Scan | ||||
| distance relay | ASEA Catalogue RK 61 -20 E Edition 1 1 3 8 1 -0 4 File R Part i Distance relay type RAZOA ■Used for cables and overhead t<ansinisslon lines Three-phase switched-scheme relay of compact $iatic design Overcurnent start Healthy phase polarisation and memory |
OCR Scan | ||||
| racic | A S p Sp _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ASEA BROWN BOVERI « ,« , ________________________________________________________________________________________________________________ _ Type RACIC B03-7210 Feeder protection January 1985 Changed since May 1983 |
OCR Scan | ||||
| rel 100 | Line protection REL 100 1MRK 506 007-BEN (SE970130) Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice Features • Simultaneous phase-phase and phaseearth loop impedance measurement, with individual numerical measuring elements |
Original | ||||
| SR Feeder Management Relay® 6 Complete, | SR Feeder Management Relay® 6 Complete, economical protection and monitoring of industrial and utility feeders. Features and Benefits Q Digital relay Q Tracks power system frequency Q Adjusts sampling rate to maintain accuracy Q Incorporates protection, control and |
Original | ||||
| A S E A C atalog u e RK 61 -15 E Edition 1 S | A S E A C atalog u e RK 61 -15 E Edition 1 S eptem ber 1981 File R, Part 1 Feeder protection type RACIB The RACIB feed er protection is intended prim arily fo r use in radial-supplied pow er distribution networks. The pro tection c o n ta in s : • A three-phase tim a^overcurrent relay w ith starting, |
OCR Scan | ||||
| A SEA Catalogue RK 65-20 E Edition 1 Directional | A SEA Catalogue RK 65-20 E Edition 1 Directional protective relays A ugust 1976 File R, Part 1 C lO lM f B T l 1F IL 1 E IX P • Used, among other things, in shortcircu it protection and earth-fault pro tection for cables and overhead lines, in out-of-step protection fo r |
OCR Scan | ||||
| 090-bus | Transformer protection IED RET 670 Buyer's Guide Customized 1MRK 504 090-BUS Product version: 1.1 Revision: A Issued: November 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration |
Original | ||||
| 279-bus | Line distance protection IED REL 670 Buyer's Guide Customized 1MRK 506 279-BUS Product version: 1.1 Revision: A Issued: November 2007 Data subject to change without notice Page 1 Features • A protection, control, and monitoring IED with extensive functional library and configuration |
Original | ||||