DIAPHRAGM PUMP Search Results
DIAPHRAGM PUMP Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TPS60110PWP | Texas Instruments | 3 cell to regulated 5V, 300-mA low noise charge pump 20-HTSSOP -40 to 85 |
|
|
|
| TPS60141PWPR | Texas Instruments | Regulated 5-V Charge Pump Voltage Tripler With Power Good Indicator 20-HTSSOP -40 to 85 |
|
|
|
| TPS60202DGSR | Texas Instruments | Regulated 3.3V 50mA, low ripple charge pump with low battery indicator 10-VSSOP -40 to 85 |
|
|
|
| TPS60205DGS | Texas Instruments | Regulated 3.3V low ripple charge pump with power good indicator 10-VSSOP -40 to 85 |
|
||
| TPS60252RTER | Texas Instruments | High Efficiency Charge Pump for 7 WLEDs with I2C Interface 16-WQFN -40 to 85 |
|
|
Documents mentioning DIAPHRAGM PUMP
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| T2-03 Miniature diaphragm pumps FEATURES · | T2-03 Miniature diaphragm pumps FEATURES · Ultra-compact size, long life, and high efficiency · Ideal for use in portable air and gas applications · Intrinsically safe motors · Broad media compatibility · Contamination-free WETTED MATERIALS Diaphragm: EPDM, FKM or Neoprene |
Original | ||||
| FORM 1082 (REV. B) 9/03 INSTALLATION INSTRUCTIONS | FORM 1082 (REV. B) 9/03 INSTALLATION INSTRUCTIONS REGULATOR WARNING This kit contains a flat diaphragm assembly that is designed to replace the old “bell” style (concave) diaphragm assembly. Because it will not fit in regulators with dual (high pressure) |
Original | ||||
| px540 | ® PX540 Series Pressure Transducers Operator’s Manual: M1137/0698 General Description The OMEGA® PX540 Pressure Transducer consists of a pressure connection section with welded stainless steel diaphragm and a case for housing the electronic equipment and the electrical connection. The piezoresistive pressure sensor is installed behind the diaphragm, with the intervening space filled with silicone oil as pressure transmission liquid. |
Original | ||||
| infusion pump | Pressure Sensor Force/Pressure Transducer FEATURES • Silicon pressure/force interface diaphragm • Force measurement for infusion pump applications • Pressure measurement for liquid media • Medical-grade materials • 8-pin DIP electrical connection |
Original | ||||
| T2-05 Miniature diaphragm pumps FEATURES · | T2-05 Miniature diaphragm pumps FEATURES · Ultra-compact size, long life, and high efficiency · Ideal for use in portable air and gas applications · Quiet operation and low vibration · Intrinsically safe motor · Broad media compatibility · Contamination-free |
Original | ||||
| ld500 | LD500 pressure transmitter Description LD500 pressure transmitter adopts the high accurate and stable isolation sensors from USA, which combine solid-state integration technique with isolation diaphragm technique. The product preserves high sensitivity, linearity and stability even |
Original | ||||
| 1200 Series / 1600 Series – OEM Transducers | 1200 Series / 1600 Series – OEM Transducers Featuring Exceptional Proof Pressure and Stability Specifications Gauge, Vacuum, and Compound Pressure Models General Purpose and Wash down Enclosures High Proof Pressure Achieved by Thicker Diaphragm Construction |
Original | ||||
| PRESSURE REFERENCE SECTION PRESSURE MEASUREMENT | PRESSURE REFERENCE SECTION PRESSURE MEASUREMENT PRESSURE SENSOR VS PRESSURE TRANSDUCER 1. An integral pressure interface (diaphragm) that isolates and couples the measurand to the sensing elements (strain gages) Z-9 +180 +160 OUTPUT VOLTAGE (% OF FULL SCALE) |
Original | ||||
| Issued September 2000 232-5244 Data Pack E | Issued September 2000 232-5244 Data Pack E Pressure transducers and instrumentation Data Sheet Two ranges of silicon diaphragm gauge pressure transducers, one with a built-in reference tube and one with an integral ventilated cable. The reference tube type allows transducers to be remotely |
Original | ||||
| T2-06 High flow, compact diaphragm pumps FEATURES | T2-06 High flow, compact diaphragm pumps FEATURES · Compact size, long life and efficiency · Single or twin head versions · Ideal for use in portable air and gas applications · Up to 6 or 12 lpm free flow, pressure up to 1.3 bar and vacuum up to 576 mbar |
Original | ||||
| PSIBAR® CVD types 1200 Series / 1600 Series – OEM | PSIBAR® CVD types 1200 Series / 1600 Series – OEM Transducers Featuring Exceptional Proof Pressure and Stability Specifications Gauge, Vacuum, and Compound Pressure Models General Purpose and Wash down Enclosures High Proof Pressure Achieved by Thicker Diaphragm Construction |
Original | ||||
| e9940 | Issued March 1992 E9940 Pressure transducers and instrumentation Two ranges of silicon diaphragm gauge pressure transducers, one with a built-in reference tube and one with an integral ventilated cable. The reference tube type allows transducers to be remotely mounted via a connecting pressure tube to |
Original | ||||
| infusion pumps | MODEL 85 Flush Mount 316L SS Pressure Sensor • Dialysis Machines High Performance Flush Diaphragm • Infusion Pumps 0-100 mV Output • Medical Systems Absolute and Gage • Pressure Transmitters • Level Systems Low Pressure DESCRIPTION Pressure The Model 85 Flush Mount is a small profile, media compatible, piezoresistive silicon pressure sensor packaged in a 316L |
Original | ||||
| SERIES LED Display Anti-corrosive Digital | SERIES LED Display Anti-corrosive Digital Pressure Sensor DP2 PRESSURE SENSORS DP-Y DP3 DP-Y LED Digital Display Pressure Measurement of Corrosive Gases and Liquids Possible! PE LED Bar Display DP-M Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless |
Original | ||||
|
|
||||||
| Diaphragm seals D912 Flanged chemical seals Main | Diaphragm seals D912 Flanged chemical seals Main features Pressure range from 10 mbar to 100 bar Flange class 150 to 600 DN15 to DN50 Temperature -40 °C to +400 °C Stainless steel 1.4404 NACE Applications Pressure, level or flow measurement. Mounted on differential, absolute or gauge pressure transmitters. |
Original | ||||
| pressure products PWC – Pressure Transmitter | pressure products PWC – Pressure Transmitter circuit) or optional 0–10 VDC. The PWC is available in pressure ranges from vacuum to 5,000 psi, gage or absolute. The PWC uses silicon strain gages in a full bridge circuit bonded to a stainless steel diaphragm. The output from the |
Original | ||||
| mpx2050 | MOTOROLA Order this document by MPX2050/D SEMICONDUCTOR TECHNICAL DATA The MPX2050 series device is a silicon piezoresistive pressure sensors providing a highly accurate and linear voltage output — directly proportional to the applied pressure. The sensor is a single, monolithic silicon diaphragm with the strain gauge and a thin–film |
Original | ||||
| ProMinent® Product Catalog S e c t i o n Ta b R e | ProMinent® Product Catalog S e c t i o n Ta b R e f e r e n c e Table of Contents… II SECTION TABS PA G E 1 PA G E 2 7 PA G E 6 7 Solenoid & motor pump overview |
Original | ||||