| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| an1621 | AN1621 APPLICATION NOTE 300W SECONDARY CONTROLLED TWO-SWITCH FORWARD CONVERTER WITH L5991A 1 INTRODUCTION A typical off-line isolated switch-mode power supply has the controller located on the primary side of the transformer, whereas the output voltages to be controlled and the housekeeping functions are located on the secondary side. Usually the voltage feedback signal is transferred to the primary controller by using an optocoupler |
Original | ||||
| l4990 | APPLICATION NOTE 300W SECONDARY CONTROLLED TWO-SWITCH FORWARD CONVERTER WITH L4990A by: N.Tricomi C. Adragna INTRODUCTION A typical off-line isolated switch-mode power supply has the controller located on the primary side of the transformer, whereas the output voltages to be controlled and the housekeeping functions are located on the secondary side. Usually |
Original | ||||
| an890 | AN890 APPLICATION NOTE 300W SECONDARY CONTROLLED TWO-SWITCH FORWARD CONVERTER WITH L4990A by: N.Tricomi C. Adragna INTRODUCTION A typical off-line isolated switch-mode power supply has the controller located on the primary side of the transformer, whereas the output voltages to be controlled and the housekeeping functions are located on the secondary side. Usually |
Original | ||||
| l4990 | APPLICATION NOTE 300W SECONDARY CONTROLLED TWO-SWITCH FORWARD CONVERTER WITH L4990A by: N.Tricomi C. Adragna INTRODUCTION A typical off-line isolated switch-mode power supply has the controller located on the primary side of the transformer, whereas the output voltages to be controlled and the housekeeping functions are located on the secondary side. Usually |
Original | ||||
| l4990a | APPLICATION NOTE 300W SECONDARY CONTROLLED TWO-SWITCH FORWARD CONVERTER WITH L4990A by: N.Tricomi C. Adragna INTRODUCTION A typical off-line isolated switch-mode power supply has the controller located on the primary side of the transformer, whereas the output voltages to be controlled and the housekeeping functions are located on the secondary side. Usually |
Original | ||||
| an890 | AN890 APPLICATION NOTE ® 300W SECONDARY CONTROLLED TWO-SWITCH FORWARD CONVERTER WITH L4990A by: N.Tricomi C. Adragna INTRODUCTION A typical off-line isolated switch-mode power supply has the controller located on the primary side of the transformer, whereas the output voltages to be controlled and the housekeeping functions are located on the secondary side. Usually |
Original |