Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    D50 CONTACTO Search Results

    Documents mentioning D50 CONTACTO

    Document Partial File Text Tags Type PDF
    lc1 d40
    Repair Parts D- and F-Line AC Coils www.SquareD.com FOR CURRENT INFORMATION For LC1 D40, D50, D65, D80 Rated voltage nominal voltage V 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Specification Average consumption - inrush (inductance .75)
    Original PDF
    l
    Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (θ ≤ 55 °C) 1 Rated operational
    Original PDF
    Overload Relays D-Line Bimetallic www.SquareD.com
    Overload Relays D-Line Bimetallic www.SquareD.com FOR CURRENT INFORMATION Ambient Bi-metallic overload relays LRD overload relays are designed for direct mounting to D-line contactors. To mount these overloads separately, select separate mount kits from the
    Original PDF
    Industrial Control Transformers Class 9070
    Industrial Control Transformers Class 9070 Catalog August 05 CONTENTS Description… Page Product Description… 3
    Original PDF
    Motor control device 1-1 Termal overload relay JRS3(3RU) series thermal relay Applications JRS3(3RU)series thermal relays are suitable for using in the power system with AC 50/60Hz, rated operaton voltage up to 690-1000V, rated operation current from 0.1A to 100A.They are used to protect AC 3 phase
    Original PDF
    References 6 TeSys protection components 6 3-pole
    References 6 TeSys protection components 6 3-pole thermal overload relays, model d 810464 Differential thermal overload relays for use with fuses b Compensated relays with manual or automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A)
    Original PDF
    lc1-d
    Contactors and protection relays Contactors, types LC1-D Selection guide : pages 1/12 to 1/43 Characteristics : pages 2/56 to 2/69 References : pages 2/70 to 2/77 Schemes : pages 2/92 and 2/93 Dimensions c 12,5 (LA8) c1(LA1) 45 12,5 (LA8) 56 107(3)(DF,DT)
    Original PDF
    Issued November 2009 DATA SHEET LR-D OVERLOAD
    Issued November 2009 DATA SHEET LR-D OVERLOAD RELAYS Based on Schneider MKTED205103EN Catalogue 12493 General 6 12493 Protection components 6 Motor protection Operating conditions There are many possible causes of electric motor failure. One of the most common,
    Original PDF
    24516 Page 108 Friday, October 26, 2001 9:32 AM
    24516 Page 108 Friday, October 26, 2001 9:32 AM Description, characteristics TeSys protection components 3-pole thermal overload relays, model d Description Model d 3-pole thermal overload relays are designed to protect a.c. circuits and motors against overloads, phase failure,
    Original PDF
    tesys contactors
    References TeSys contactors a.c. coils for 3-pole contactors LC1-D Control circuit voltage Uc V Average resistance at 20 °C ± 10 % Ω Inductance of closed circuit H Reference (1) Weight kg For 3-pole " contactors LC1-D09…D38 and LC1-DT20…DT60 Specifications
    Original PDF
    tesys
    24505 Page 62 Thursday, October 25, 2001 5:44 PM Characteristics TeSys contactors Model d Farnell Codes ; 4231855 - 4232148 Type of contactor LC1LC1D09…D18 D25…D38 DT20 & DT25 DT32…DT6 LC1D40 1000 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui)
    Original PDF
    lc1lc1lc1d09
    Characteristics TeSys contactors 5 Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32 & DT40 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) 2 Rated impulse withstand voltage (Uimp) Conforming to IEC EN 947-4-1,
    Original PDF
    lc1-d115
    Characteristics TeSys contactors Model d Type of contactor LC1LC1LC1D09…D18 D25…D38 D40 DT20 & DT25 DT32…DT60 LC1D50…D95 LC1-D115 & LC1-D150 Environment Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) 2 Conforming to EN 60947-4-1,
    Original PDF
    Contactors and protection relays Selection guide
    Contactors and protection relays Selection guide pages 1 '12 tu 1/43 References . uages 2/70 to 2''101 Dimensions pages 2/88 to 2*91 2/102 and 2/103 Schemes pages 2/92. 2'93 and 2 /’ 03 Type Contactors, types LC1-D and LP1-D Control circuit: a.c. or d.c.
    OCR Scan PDF
    Motor Control Device 1-1 Magnetic latching
    Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.
    Original PDF
    Motor control 1 TeSys range provide you more
    Motor control 1 TeSys range provide you more simplicity, compactness, openness and flexibility… so many evolutions and new items to aid your productivity. 2 Accurate and reliable control of motors 3 4 5 6 7 Increase your productivity, adopt our solutions which help to simplify
    Original PDF
    GE Energy Industrial Solutions 51210 GE Energy
    GE Energy Industrial Solutions 51210 GE Energy Industrial Solutions GE Industrial Solutions Industrial Solutions (formerly Power Protection) a division of GE Energy, is a first class European supplier of low-voltage products including wiring devices, residential and
    Original PDF
    Safety Relay Unit G9SA • Four kinds of 45-mm wide
    Safety Relay Unit G9SA • Four kinds of 45-mm wide Units are available: A 3-safety contact model, a 5-safety contact model, and models with 3 safety contacts and 2 OFF-delay safety contacts. Also available are 17.5-mm wide Expansion Units with 3 safety contacts and 3 OFF-delay safety contacts.
    Original PDF
    Selection 5 TeSys contactors 5 For utilisation
    Selection 5 TeSys contactors 5 For utilisation category AC-3 Operational current and power conforming to IEC (θ y 60 °C) 1 Contactor size Maximum operational current in AC-3 Rated operational power P (standard motor power ratings) 2 3 y 440 V A LC1/ LP1
    Original PDF
    FF-SRST Emergency Stop Module with Timer FEATURES
    FF-SRST Emergency Stop Module with Timer FEATURES • Complies with the Machinery Directive for 98/37/EC, IEC 204, EN 60204, DIN VDE 0113 and UL 508 • Dual channel input • Safety outputs: two direct NO contacts, one direct NC contact, two NO delayed contacts and one NC delayed contact
    Original PDF
    Soft starters ATS 01 Catalogue May 07 General
    Soft starters ATS 01 Catalogue May 07 General contents Soft starters for asynchronous motors 1 – Altistart 01 2 – Altistart U01 1 Contents 1 - Altistart 01 soft starters for asynchronous motors b Presentation… pages 1/2 and 1/3
    Original PDF
    MITSUBISHI ELECTRIC MELSEC FX Series Programmable
    MITSUBISHI ELECTRIC MELSEC FX Series Programmable Logic Controllers User's Manual (Hardware) FX3U Base Units and Extension Blocks Art. no: 168590 01062007 Version E MITSUBISHI ELECTRIC INDUSTRIAL AUTOMATION Safety Precautions (Read these precautions before use.)
    Original PDF
    Selection guide TeSys Model U Starter-controllers
    Selection guide TeSys Model U Starter-controllers Control units Function characteristics Control units Standard LUCA Thermal overload protection Overcurrent protection Advanced LUCB LUCC LUCD 14.2 x the setting current Short-circuit protection Protection against phase loss
    Original PDF
    DVP-PM APPLICATION MANUAL Table of Contents
    DVP-PM APPLICATION MANUAL Table of Contents Chapter 1: Program Structure of DVP-PM 1.1 O100 Main Program… 1-1 1.1.1 Manual Motion in O100 Main Program… 1-2
    Original PDF
    Presentation TeSys protection components
    Presentation TeSys protection components Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 GV2-ME, GV2-P, GV3-ME and GV7-R motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers specifically designed for the control and protection of motors, conforming to standards IEC 947-2 and IEC 947-4-1.
    Original PDF