CONTINUOUS WATER LEVEL SENSOR Search Results
CONTINUOUS WATER LEVEL SENSOR Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TC7MP3125FT | Toshiba Electronic Devices & Storage Corporation | Level shifter, Bidirectional, 2-Bit x 2 Dual Supply Bus Transceiver, TSSOP16B, -40 to 85 degC | Datasheet | ||
| 74LV4T126FK | Toshiba Electronic Devices & Storage Corporation | Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC | Datasheet | ||
| 74LV4T125FK | Toshiba Electronic Devices & Storage Corporation | Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, US14, -40 to 125 degC | Datasheet | ||
| 7UL1T04NX | Toshiba Electronic Devices & Storage Corporation | One-Gate Logic(L-MOS), Inverter with Level Shifting, XSON6, -40 to 125 degC | Datasheet | ||
| 74LV4T126FT | Toshiba Electronic Devices & Storage Corporation | Level shifter, Unidirectional, 1-Bit x 4 Single Supply Bus Buffer, TSSOP14, -40 to 125 degC, AEC-Q100 | Datasheet |
Documents mentioning CONTINUOUS WATER LEVEL SENSOR
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| pn-12110215tc-12 | Continuous Fluid Level Sensor PN-12110215TC-12 eTape TM Description The eTape sensor is a solid state, continuous (multi-level) fluid level sensor for measuring levels in water, non-corrosive water based liquids and dry fluids (powders). The eTape sensor is |
Original | ||||
| Digital Fluid-Trac Ultrasonic Drum Level Gauge | Digital Fluid-Trac Ultrasonic Drum Level Gauge NEW! Description: This drum level gauge is a cost competitive non-contact continuous liquid level drum gauge. Designed for use on vertical drums storing a wide variety of media such as water, waste water, motor oil, hydraulic fluid and diesel |
Original | ||||
| IML Hydrostatic level transmitter Stainless Steel | IML Hydrostatic level transmitter Stainless Steel Submersible Transmitter with Stainless steel or Ceramic pressure sensor nominal pressure ranges: Stainless steel: 0 - 0.5mWG up to 0 – 5mWG Ceramic: 0 - 5mWG up to 0 - 200mWG The IML series hydrostatic level transmitters are designed for continuous level measurement of rivers, reservoirs or tank level measurement of water, fuels or oils. |
Original | ||||
| fluid level measurement | LMP 307 Stainless Steel Probe with Stainless Steel Sensor ► The submersible level transmitter LMP 307 has been designed for continuous fluid level measurement in water and clean to slightly contaminated media. In addition the several cable materials (PVC, PUR and FEP) the customer has the |
Original | ||||
| ls05 | Reed Technology Solutions Product Spotlight REED RELAYS REED SENSORS REED SWITCHES LS05 Series Liquid Level Sensors DESCRIPTION • Choose from hundreds of preselected The LS05 Liquid Level Sensors reach new levels! Made of tough material options to customize a sensor |
Original | ||||
| Data Sheet 2101171-AF Liquid Custody Transfer | Data Sheet 2101171-AF Liquid Custody Transfer Level Sensor Products Application DESCRIPTION TRADITIONAL TANK SALES The LevelMaster Intelligent Digital Level Sensor is deployed in oil and gas industry as a custody transfer device. For custody transfer applications, the |
Original | ||||
| sq-sen-200 | DATASHEET SQ-SEN-200 OMNIDIRECTIONAL TILT AND VIBRATION SENSOR RoHS compliant, lead-free SMD package DESCRIPTION The SQ-SEN-200 series sensor acts like a normally closed switch which chatters open and closed as it is tilted or vibrated. Unlike other rolling-ball sensors, the 200 is truly an |
Original | ||||
| WILLOW Technologies Sensors Ultrasonic MA Series | WILLOW Technologies Sensors Ultrasonic MA Series These sensors transmit and receive ultrasonic waves, having applications in distance measurement (vehicle reversing aids etc), object detecting, security alarms and remote control Features 1. Compact and lightweight design |
Original | ||||
| reedswitch | Series RSF30 LIQUID LEVEL SENSORS - REEDSWITCH CONTACTS • Simple to Mount and Use • User Configurable Switching Options • Available in GFS Nylon, Polypropylene, Polysulfone and PPS** • UL & FDA Approved The RSF30 series of float switch are a range of general purpose, high |
Original | ||||
| ultrasonic | Ultrasonic Sensors Ultrasonic MA Series 1- Open Structure Types These sensors transmit and receive ultrasonic waves, having applications in distance measurement (vehicle reversing aids etc), object detecting, security alarms and remote control Features 1. Compact and lightweight design |
Original | ||||
| ® EchoSwitch® LU74/77/78 Ultrasonic Level Switch | ® EchoSwitch® LU74/77/78 Ultrasonic Level Switch Application LU74 / 78 Faceplate LU77 The general purpose ultrasonic level sensor provides continuous level detection up to 26.2’ (8m) with 3 programmable relays for level switch or level control functions, and a 4-20mA signal output. The sensor |
Original | ||||
| ModSTACK TM Data Sheet: 2B6I 500/800-450W | ModSTACK TM Data Sheet: 2B6I 500/800-450W Preliminary Data Key Data 2 x 3 x 450A AC at 500V AC, water cooled General Information Stack with IGBT’s, heatsinks, capacitors, drivers and sensors for several inverter applications. These are only technical data! Please read heedful the complete documentation and attend the |
Original | ||||
| DISCRIMINATING LIQUID SENSOR for Interstitial | DISCRIMINATING LIQUID SENSOR for Interstitial Applications Shown Actual Size Double-Wall Tanks, Containment Sumps, and Double-Wall Pipes Applications Integral Pull Your Controls Containment S ump Model LV132 $ 160 MADE IN USA ߜ Three Distinct Outputs: Dry, Water Present, Fuel |
Original | ||||
| capacitive | Level Sensors Capacitive Level Detector Type CD50 DC • Basic capacitive water level sensor For water storage tanks in mini-pools and whirlpools Detection of excess water in the whirlpool tub Safety device to control the operation of the pump. |
Original | ||||
|
|
||||||
| REFERENCE A N D APPLIC ATIO N DATA Pressure | REFERENCE A N D APPLIC ATIO N DATA Pressure Sensors Pressure Sensor Auto-Referencing - Note # 1 0 INTRODUCTION Pressure sensors are not “ ideal” devices. Laser trimming on MICRO SWITCH high level amplified sensors reduces null and full scale errors to approximately 1% to |
OCR Scan | ||||
| lmt100 | Level sensors LMT100 Electronic level sensor LMT Connector Process connection: G½ gold-plated contacts 2 switching outputs normally open / closed complementary 1: tightening torque 20…25 Nm Made in Germany Application water, water-based medium Electrical design |
Original | ||||
| modstack | ModSTACK Data Sheet: 2B6I 500/800-400G M, S Preliminary Data Key Data 2 x 3 x 400A AC at 500V AC, air cooled General Information Stack with IGBT’s, heatsinks, capacitors, drivers and sensors for several inverter applications. These are only technical data! Please read heedful the complete documentation and attend the |
Original | ||||
| microsens | Microsens Amperometric Sensor MAES-2402, Chlorine (HOCl) Sensor General description Operating principle The integrated chlorine sensor MAES-2402 measures the concentration of Hypochlorous Acid (HOCl) in water using the principle of conventional amperometric technique. |
Original | ||||
| Liquid Level Sensors Capable of Operating in | Liquid Level Sensors Capable of Operating in Harsh Environments up to 200° 200°C REED RELAYS REED SENSORS REED SWITCHES Introduction High temperature liquid environments have been around for a long time without any accurate, easy method of measuring their liquid levels. MEDER has solved |
Original | ||||
| Small Size – Alloys Ordering is Easy! See Page | Small Size – Alloys Ordering is Easy! See Page C-12. Easy online ordering too! LEVEL SENSORS – CONTINUOUS XM/XT-800 Series – Compact Analog Sensors Lengths to 12 ft! Stainless or Brass Construction 1/4˝ Resolution Lengths to 144 inches OEM Configurations Available |
Original | ||||
| Ceramic PTC thermistors as sensors Level | Ceramic PTC thermistors as sensors Level measurement made easy The reference temperature or Curie point of a PTC thermistor depends on the composition of the ceramic material. Siemens Matsushita Components offers PTC thermistors with reference temperatures from |
Original | ||||