| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| FO-9LPBMTRJ00-001 | Amphenol Cables on Demand | Amphenol FO-9LPBMTRJ00-001 MT-RJ Connector Loopback Cable: Single-Mode 9/125 Fiber Optic Port Testing .1m | |||
| SF-QXP85B402D-000 | Amphenol Cables on Demand | Amphenol SF-QXP85B402D-000 QSFP28 100GBASE-SR Short-Range 850nm Multi-Mode Optical Transceiver Module (MTP/MPO Connector) by Amphenol XGIGA [QXP85B402D] | |||
| SF-XP85B102DX-000 | Amphenol Cables on Demand | Amphenol SF-XP85B102DX-000 SFP28 25GBASE-SR Short-Range 850nm Multi-Mode Optical Transceiver Module (Duplex LC Connector) by Amphenol XGIGA [XP85B102DX] | |||
| FO-DLSCDLLC00-001 | Amphenol Cables on Demand | Amphenol FO-DLSCDLLC00-001 SC-LC Duplex Single-Mode 9/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x SC Male to 2 x LC Male 1m | |||
| FO-DLSCDLLC00-002 | Amphenol Cables on Demand | Amphenol FO-DLSCDLLC00-002 SC-LC Duplex Single-Mode 9/125 Fiber Optic Patch Cable (OFNR Riser) - 2 x SC Male to 2 x LC Male 2m |
Documents mentioning COMPACTPCI FAILURE MODE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 50gbps | VERSION 1.0 2002 GigaBridge™ GBP H i g h Pe r f o r m a n c e ■ Supports multiple concurrent transactions ■ 6.4Gbps LVDS link interface ■ Up to 50Gbps aggregate bandwidth Scalability ■ Connects up to 224 PCI bus segments ■ Eliminates need for stacked |
Original | ||||
| dialogic | Datasheet Telecom Software Intel® Dialogic® System Release 6.0 CompactPCI* Feature Pack 1 for Windows* Feature Pack 1 for Windows* continues expanding Redundant Host (RH) and Redundant System Slot (RSS) on the CompactPCI* form factor and enhances redundant single board computer (SBC) support |
Original | ||||
| cPCI500 Series 500W 6Ux4HP DC/DC CompactPCI™ | cPCI500 Series 500W 6Ux4HP DC/DC CompactPCI™ Power Supply SELECTION GUIDE S Model Number Power Output Current 5V 3.3V 12V -12V IPMI Ish1 CPCI500D-1 C 500W 55A Y 11A 1.7A N P No CPCI500D-2 C 500W 30A N 11A 1.7A N P No C CPCI500D-3 500W 30A N 11A 1.7A Y A |
Original | ||||
| NOT RECOMMENDED cPCI500 Series 500W 6Ux4HP DC/DC | NOT RECOMMENDED cPCI500 Series 500W 6Ux4HP DC/DC CompactPCI™ Power Supply FOR NEW DESIGNS SELECTION GUIDE S Model Number Power Output Current 5V 3.3V 12V -12V IPMI Ish1 CPCI500D-1 C 500W 55A Y 11A 1.7A N P No CPCI500D-2 C 500W 30A N 11A 1.7A N P No C CPCI500D-3 |
Original | ||||
| an5760 | MSAN-191 Designing a HotSwap Board with Zarlink Components Application Note Contents AN5760 1.0 Overview 2.0 System Models 3.0 Physical Connection Process 3.1 Insertion Process 3.2 Extraction Process 4.0 Hot Swap Technical Specifications 4.1 Power Usage 4.2 CT Bus Signal Conditioning |
Original | ||||
| Datasheet Telecom Software Intel® Dialogic® | Datasheet Telecom Software Intel® Dialogic® System Release 6.0 CompactPCI for the Linux Operating Systems Intel® Dialogic® System Release 6.0 supports new high-density Intel NetStructure® boards on the CompactPCI* form factor, and delivers a wealth of features that enhance system availability. |
Original | ||||
| gbp32 | GigaBridgeTM GBP32 PCI Adaptive Switch Fabric Controller Investment Preservation • Preserves PCI-based SW and HW investments • Operates as a PCI-to-PCI bridge • PCI Local Bus Specification Rev. 2.2 compatible • CompactPCI Rev. 2.1 (PICMG 2.0) compatible |
Original | ||||
| CompactPCI ® SYSTEM POWER SUPPLIES CPCI SERIES | CompactPCI ® SYSTEM POWER SUPPLIES CPCI SERIES 200 Watts, Ac Input with PFC DPCI SERIES 200 Watts, 48 Vdc Input EXECUTIVE MEMBER FEATURES: • 200 W in 3U x 8HP, Fully compliant with PICMG CompactPCI® specifications Current sharing and internal OR-ing diodes for N+1 redundancy |
Original | ||||
| CompactPCI ® SYSTEM POWER SUPPLIES CPCI SERIES | CompactPCI ® SYSTEM POWER SUPPLIES CPCI SERIES 150 to 350 Watts, Ac Input with PFC DCPI SERIES 150 to 350 Watts, 48 Vdc Input EXECUTIVE MEMBER FEATURES: • 150 W and 200 W in 3U x 8HP, 350 W in 6U x 8HP Fully compliant with PICMG CompactPCI® specifications |
Original | ||||
| CPCI Series / DPCI Series 200 Watts CompactPCI® | CPCI Series / DPCI Series 200 Watts CompactPCI® System Power Supplies CPCI SERIES 200 Watts, Ac Input with PFC DPCI SERIES 200 Watts, 48 Vdc Input FEATURES: INPUT FAULT CPCI200 EXECUTIVE MEMBER • 200 W in 3U x 8HP, • Fully compliant with PICMG CompactPCI® specifications |
Original | ||||
| CompactPCI ® SYSTEM POWER SUPPLIES CPCI SERIES | CompactPCI ® SYSTEM POWER SUPPLIES CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input EXECUTIVE MEMBER FEATURES: • 150 W and 200 W in 3U x 8HP, 350 W in 6U x 8HP Fully compliant with PICMG CompactPCI® specifications |
Original | ||||
| CPCI Series / DPCI Series 200 Watts CompactPCI® | CPCI Series / DPCI Series 200 Watts CompactPCI® System Power Supplies CPCI SERIES 200 Watts, Ac Input with PFC DPCI SERIES 200 Watts, 48 Vdc Input FEATURES: INPUT FAULT CPCI200 EXECUTIVE MEMBER • 200 W in 3U x 8HP, • Fully compliant with PICMG CompactPCI® specifications |
Original | ||||
| R High Current Density CompactPCI Power Data | R High Current Density CompactPCI Power Data Sheet Power-One's CompactPCI® Power Solutions Provide Extremely-High Current Densities Overview ® Power-One’s CompactPCI power solutions are ® fully compliant to the PICMG 2.11 Power Interface Specification using a standard |
Original | ||||
| power-one | R High Current Density CompactPCI Power Data Sheet Power-One's CompactPCI® Power Solutions Provide Extremely-High Current Densities Overview ® Power-One’s CompactPCI power solutions are ® fully compliant to the PICMG 2.11 Power Interface Specification using a standard |
Original | ||||
|
|
||||||
| R High Current Density CompactPCI Power Data | R High Current Density CompactPCI Power Data Sheet Power-One's CompactPCI® Power Solutions Provide Extremely-High Current Densities Overview ® Power-One’s CompactPCI power solutions are ® fully compliant to the PICMG 2.11 Power Interface Specification using a standard |
Original | ||||
| Intel® NetStructureTM ZT 5085 12U Redundant Host | Intel® NetStructureTM ZT 5085 12U Redundant Host Packet Switched Platform Technical Product Specification July 2003 Order Number: 273790-004 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN |
Original | ||||
| Intel® NetStructureTM ZT 5085 12U Redundant Host | Intel® NetStructureTM ZT 5085 12U Redundant Host Packet Switched Platform Technical Product Specification October 2004 Order Number: 273790-005 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY |
Original | ||||
| netstructure | Product Brief Intel NetStructure ZT 5504 System Master Processor Board ® ™ Introduction Highlights Designed to the PICMG* 2.16 specification, this Computing Core processor board offers excellent value with an ■ optimized feature set to support a broad range of |
Original | ||||
| VMICPCI-4320 CompactPCI 8-Channel Analog Output | VMICPCI-4320 CompactPCI 8-Channel Analog Output Board Product Manual 12090 South Memorial Parkway Huntsville, Alabama 35803-3308, USA (256) 880-0444 w (800) 322-3616 w Fax: (256) 882-0859 500-654320-000 Rev. B 12090 South Memorial Parkway Huntsville, Alabama 35803-3308, USA |
Original | ||||
| Intel® NetStructureTM ZT 5088 12U General Purpose | Intel® NetStructureTM ZT 5088 12U General Purpose Packet Switched Platform Technical Product Specification July 2003 Order Number: 273789-003 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY |
Original | ||||
| Revised April 2002 Section 2 - Backplane | Revised April 2002 Section 2 - Backplane Protocols Backplane Designer’s Guide Backplane bus protocols determine - electrically and mechanically - how signals are dropped off or picked up at every device attached to the line. Protocols determine how cards pass information, the speed of data transfer, the maximum number and type of peripheral devices allowed, and the physical size and layout of the system. In general, the choice of the correct protocol for a backplane design is a complex decision that involves many design compromises. No one solution will |