    Part ECAD Model Manufacturer Description Download Buy
    DS3680D
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy
    ULN2003LVPWR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 Visit Texas Instruments Buy
    ULN2003V12PWR
    Texas Instruments Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 Visit Texas Instruments Buy
    ULN2003LVDR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 Visit Texas Instruments Buy
    DS3680DE4
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy

    Documents mentioning CENELEC RELAY

    Document Partial File Text Tags Type PDF
    Switch-Tek Switch-Tek Ultrasonic LU10 0510 DS2_3
    Switch-Tek Switch-Tek Ultrasonic LU10 0510 DS2_3 TM Ultrasonic Level Switch Features 1A relay selectable NO or NC via power supply wiring polarity CSA & Cenelec approved intrinsically safe for use in hazardous areas Specifications Universal ± 1 mm in water
    Original PDF
    PCB Relay G5B Single-pole 3-A Miniature Relay
    PCB Relay G5B Single-pole 3-A Miniature Relay Impulse withstand voltage of 10 kV (between coil and contact). Models available with 200-mW current consumption (High-sensitivity Type). High-capacity (8 A) type available. IEC/CENELEC/UL/CSA/SEMKO approved. VDE
    Original PDF
    Data Sheet SS/6553_3 ATEX Compliant Gas Analyzer
    Data Sheet SS/6553_3 ATEX Compliant Gas Analyzer for Hydrogen-cooled Alternators Type 6553 ■ CENELEC (ATEX) Certification – intrinsically safe to EExia IIC for hydrogen ■ Continuous monitoring – fail-safe alarms indicate immediate danger conditions
    Original PDF
    inductive proximity sensor
    Inductive Proximity Sensor E2Q Square Proximity Sensor Limit switch styled housing models easy to install. Standard CENELEC models and miniature types. Terminal housing, M12 Plug--in connection and cable types. Special weld--field immune models. Broad Line-up of the E2Q Series
    Original PDF
    proximity sensor
    Cylindrical Proximity Sensor E2A3 High Quality for Extra Long Distance • CENELEC triple-distance operation. • Normally open (NO), and normally closed (NC) models are available. • Stainless steel and brass housings. • 360° angle indicators <READ AND UNDERSTAND THIS CATALOG>
    Original PDF
    ultrasonic level transmitter
    Echotouch Echotouch 0504 DS3_1 TM Ultrasonic Level Transmitter Description Offered in CSA and Cenelec approved intrinsically safe or general purpose configurations, the two-wire ultrasonic transmitter provides noncontact level measurement up to 18’ or 5.4m, and is ideally suited for
    Original PDF
    Issued March 1996 021-091 Data pack B Data Sheet
    Issued March 1996 021-091 Data pack B Data Sheet ac industrial electric motors Standards’ organisations The RS-ABB range of ac induction motors is produced to common European standards, these being IEC and CENELEC (Comité Européen de Normalisation Electrotechnique).
    Original PDF
    Compliance of Infrared Communication Products to
    Compliance of Infrared Communication Products to IEC 825-1 and CENELEC EN 60825-1 Application Note 1118 Introduction Products compliant with or merely interoperable under the Infrared Data Association (IrDA) Specifications 1.0 and 1.1 also must be eye safe, and in some geographical
    Original PDF
    ab
    Issued September 2001 232-5812 Data pack B Data Sheet AC Industrial Electric Motors Standards’ organisations The RS-ABB range of ac induction motors is produced to common European standards, these being IEC and CENELEC (Comité Européen de Normalisation
    Original PDF
    ts35x15
    Accessories: Electrical Accessories Grounding Spec-00567 C PH (763) (763) 422-2600 422-2211 FX Accessories Electrical Accessories Grounding DIN Type Rails Catalog Number ADNR1 ADNR3 ACENR1 Description DIN 1 mounting rail TS32 DIN 3 mounting rail TS35x7.5 CENELEC mounting rail TS35x15
    Original PDF
    Cylindrical Proximity Sensor E2E/E2E2 A New
    Cylindrical Proximity Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Proximity Sensor Conforms to CENELEC • Ideal for a variety of applications. • With a metal connector that can be tightened securely and a cable protector.
    Original PDF
    Cylindrical Proximity Sensor E2A High quality for
    Cylindrical Proximity Sensor E2A High quality for extra long life in daily use • sensing distance approximately 1.5 to 2 times longer than standard CENELEC proximity sensors • designed and tested for extra long life • IP67 and IP69k for highest protection in wet
    Original PDF
    stm32
    STEVAL-IHP002V1 SmartPlug systems to measure and control AC loads, based on the STM32, ST7540 PLM, and STPM01 Data brief Features ■ Energy consumption monitoring ■ PLM communication ■ On/Off or dimming configuration ■ CENELEC band C compliant ■ System setting by RS232
    Original PDF
     Safety-door Switch D4BS Special Key Positively
     Safety-door Switch D4BS Special Key Positively Pulls Contacts Apart, Increasing Machine Safety  Wide operating temperature range: -40°C to 80°C  Mounting pitch and shape of the switch box conforms to CENELEC EN50041  Enclosure rating of the switch box
    Original PDF
    alternators
    Data Sheet SS/AK100 Issue 9 ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators AK100 Series „ ATEX compliant – intrinsically safe to II (1)G CENELEC EEx ia IIC T4 „ Safety – early warning of hazardous hydrogen/air mixtures „ Cost savings
    Original PDF
    Cylindrical Proximity Sensor E2E/E2E2 A New
    Cylindrical Proximity Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Proximity Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened securely and a cord protector.
    Original PDF
    Issued March 1997 232-5812 Data pack B Data Sheet
    Issued March 1997 232-5812 Data pack B Data Sheet ac industrial electric motors Standards’ organisations The RS-ABB range of ac induction motors is produced to common European standards, these being IEC and CENELEC (Comité Européen de Normalisation Electrotechnique).
    Original PDF
    Issued July 1992 B13337 ac industrial electric motors StandardsÕ organisations The RS-ABB range of ac induction motors is produced to common European standards, these being IEC and CENELEC (ComitŽ EuropŽen de Normalisation Electrotechnique). These two organisations work together on
    Original PDF
    proximity sensor
    Cylindrical Proximity Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Proximity Sensor Conforms to CENELEC • Ideal for a variety of applications. • With a metal connector that can be tightened securely and a cable protector.
    Original PDF
    Cylindrical Proximity Sensor E2E/E2E2 A New
    Cylindrical Proximity Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Proximity Sensor Conforms to CENELEC • Ideal for a variety of applications. • With a metal connector that can be tightened securely and a cord protector.
    Original PDF
    RELAIS INSTANTANE IN S TA N TA N E O U S RELAY
    RELAIS INSTANTANE IN S TA N TA N E O U S RELAY SERIE 2 5 9 4 RT - 4 PDT CA R A C TER ISTIQ U ES GENERALES GENERAL C H A R A C T E R IS TIC S 14 A 10 A 0,2V A , mini 5V ou 5m A Ag CdO doré 350 A - 30 ms 30.10e m anœ uvres Intensité nom inale therm ique Pouvoir de m anœ uvre (voir courbes)
    OCR Scan PDF
    relais temporise
    RELAIS TEMPORISE ELECTRONIQUE A L'ENCLENCHEMENT ET AU DECLENCHEMENT ELECTRONIC TIM E DELAY RELAY ON OPE RATE A N D ON RELEASE 0,15 à 180 secondes sérié 245 TE 2 RT - 2 PDT CARACTERISTIQUES GENERALES GENERAL CHARACTERISTICS Intensité nom inale therm ique • type 245 TE
    OCR Scan PDF
    RELAIS INSTANTANÉ INSTANTANEOUS RELAY SÉRIE 245 4
    RELAIS INSTANTANÉ INSTANTANEOUS RELAY SÉRIE 245 4 RT - 4 PU T CARACTÉRISTIQUES GÉNÉRALES GENERAL CHARACTERISTICS Intensité nominale (suivant le type) 3 ou 5 A Endurance mécanique 30.106 manoeuvres Tension nominale d'isolement 250 V Rigidité diélectrique entre :
    OCR Scan PDF
    Two-Wire, Process-Loop Indicator in NEMA-4X
    Two-Wire, Process-Loop Indicator in NEMA-4X Housing TX83A FM $ 325 APPROVED 2P1A7.AX LR83977 Basic Unit MADE IN USA ߜ FM, CSA, BASEEFA Intrinsic Safety Certification ߜ Powered by 1 to 5, 4 to 20 or 10 to 50 mA Signal ߜ 2.5 V Max Voltage Drop ߜ 0.35 in (8.9 mm) LCD
    Original PDF