CABLE TENSIONER Search Results
CABLE TENSIONER Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| SF-SFPP2EPASS-000.5 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-000.5 0.5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (1.6 ft) | |||
| AV-DPMDPM0000-001 | Amphenol Cables on Demand | Amphenol AV-DPMDPM0000-001 1m DisplayPort Cable - Amphenol DisplayPort 1.1 Certified Cable (3.3ft) 1m (3.3') | |||
| SF-SFPP2EPASS-001 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-001 1m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (3.3 ft) | |||
| SF-SFPP2EPASS-003 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-003 3m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (9.8 ft) | |||
| SF-SFPP2EPASS-005 | Amphenol Cables on Demand | Amphenol SF-SFPP2EPASS-005 5m SFP+ Cable - Amphenol 10GbE SFP+ Direct Attach Copper Cable (16.4 ft) |
Documents mentioning CABLE TENSIONER
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| tension | Emergency Stop Devices Cable (Rope) Pull Switches Lifeline Rope Tensioner System (LRTS) Specifications Material Tensioner Cable gripper Cable gripper gears Cable P. Bolt Glass filled nylon Acetal, aluminium alloy, stainless steel Stainless steel Cable to BS 302:1987, wire Ø4.0 |
Original | ||||
| Technical portal and online community for Design | Technical portal and online community for Design Engineers - www.element-14.com 1977 Cable Accessories Braided Sleeving… Cable Clips & Cord… Cable Glands… |
Original | ||||
| 8/18/05 3:24 PM Page 1 / Cable Fastening Systems | 8/18/05 3:24 PM Page 1 / Cable Fastening Systems Ty-Rap® /Ty-Fast® Cable Tying System Overview… 2 - 3 Ty-Rap® Cable Ties… 4 - 8 Cable Ties for Special Environments… 9 - 10 |
Original | ||||
| ty | 412031.J01 TYRAP 3/12 3/14/03 11:15 AM Page 1 / Cable Fastening Systems Ty-Rap® /Ty-Fast® Cable Tying System Overview…J2-J3 Ty-Rap® Cable Ties…J4-J8 Cable Ties for Special Environments…J9-J10 |
Original | ||||
| Emergency Stop Devices Cable (Rope) Pull Switches | Emergency Stop Devices Cable (Rope) Pull Switches Lifeline 3 Specifications Description The Lifeline 3 is a cable (rope) operated emergency stop device designed to meet the stringent requirements of EN 418 (Safety of Machinery—Emergency Stop Equipment). The Lifeline 3 system |
Original | ||||
| Emergency Stop Devices Cable (Rope) Pull Switches | Emergency Stop Devices Cable (Rope) Pull Switches Lifeline 4 Specifications Standards Approvals Safety Contact Description The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. |
Original | ||||
| Command devices Pull-wire emergency stop switches | Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 10 6 53,5 40 30 ø 10 6. 6.1 6.1.1 6.1.1.1 22 12 33 56 105 8 18 24 Pg 13,5 Features • To EN 418 • Metal enclosure • 2 contacts • Small body • 2 cable entries • Various spring force variants |
Original | ||||
| 25 cm 24 FO Plug Assembly Tool Kit HCS Quick | 25 cm 24 FO Plug Assembly Tool Kit HCS Quick Mounting Plug PSM-HCS-KONFTOOL for PSM-SET-FSMA/4-HCS 23 22 21 1. Introduction What was previously a matter for the FO specialists, is now available for general use: The on-site assembly of F-SMA plugs to HCS cable. These cables are the preferred choice in polymer fiber transmission systems |
Original | ||||
| vde 0660-200 | Components for safety applications Emergency stop trip wire switches Characteristics References : pages 3/17 to 3/22 Dimensions : page 3/23 Environment Products : XY2-CB : IEC 947-5-1, EN 60947-5-1, VDE 0660-200, CSA C 22-2 n° 14, prEN616 XY2-CE, CH, CB : IEC 947-5-1, EN 60 947-5-1, VDE 0660-200, EN 418, prEN616 |
Original | ||||
| Characteristics 5 Control and signalling units 5 | Characteristics 5 Control and signalling units 5 Emergency stop trip wire switches, type XY2 C Environment Conformity to standards Products XY2 CB: IEC/EN 60947-5-1, CSA C 22-2 n° 14 (when specified) XY2 CE, CH: IEC/EN 60947-5-1, EN 418, UL 508 and CSA C 22-2 n° 14 (when specified) |
Original | ||||
| Characteristics 5 Safety dialogue solutions | Characteristics 5 Safety dialogue solutions Emergency stop trip wire switches, type XY2 C Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n° 14 (with suffix H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006, CSA C 22-2 n° 14 (with suffix H2) |
Original | ||||
| Safety in system: Protection for man and machine | Safety in system: Protection for man and machine Main catalogue | Safety technology | Version 8.1 K.A. Schmersal GmbH & Co. KG Safety control systems Möddinghofe 30 D-42279 Wuppertal Phone: +49-(0) 2 02-64 74-0 Fax: +49-(0) 2 02-64 74-100 E-Mail: info@schmersal.com |
Original | ||||
| schmersal | L Protection – ATEX Explosion Protection Catalogue | Version 03 b_atep02v001.indd 1 08.12.2008 14:11:26 www.schmersal.com You will also find detailed information on our entire product progamme on our website: www.schmersal.com. Online documentation in six languages |
Original | ||||
| zq 700 | Datasheet - ZQ 700-11 - 1192476 - eclass 27371290 27-37-12-90 Print components Create PDF - Create EXCEL file - Hide system Page 1 of 9 28.09.2011 - 15:17:45h Datasheet - ZQ 700-11 Pull-wire emergency stop switches / ZQ 700 Preferred typ • thermoplastic enclosure |
Original | ||||
|
|
||||||
| Datasheet - ZQ 700-02 - 1192478 - eclass 27371290 | Datasheet - ZQ 700-02 - 1192478 - eclass 27371290 27-37-12-90 Print components Create PDF - Create EXCEL file - Hide system Page 1 of 9 28.09.2011 - 15:16:25h Datasheet - ZQ 700-02 Pull-wire emergency stop switches / ZQ 700 Preferred typ • thermoplastic enclosure |
Original | ||||
| Allen-Bradley 1394 Digital AC Multi-Axis Motion | Allen-Bradley 1394 Digital AC Multi-Axis Motion Control System (Catalog No. 1394-50) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control |
Original | ||||
| epic | VISHAY SFER NICE Resistive Products Application Note EPIC For more than 15 years, Vishay has been very successful in the field of electro-pyrotechnic initiators used in automotive safety devices: airbags, pre-tensioners, etc. To address the booming demand for safety devices in new cars (more than |
Original | ||||
2605 Technical portal and online community for Design Engineers - www.element-14.com Machine Safety & Limit Switches Grab Wire Switches… Hinge and Lever Switches… Limit Switches… |
Original | |||||
| Catalog 2013 ABB Safety Handbook Machine Safety - | Catalog 2013 ABB Safety Handbook Machine Safety - Jokab Safety products ABB Safety Handbook Machine Safety - Jokab Safety products Introduction 1 Directives and Standards, PL, SISTEMA, SIL, Training Pluto Safety PLC 2 Pluto, Gateway, Safe Encoder, IDFIX, program examples |
Original | ||||
| global specialist in energy management The | global specialist in energy management The architects of efficiency Singapore Mongolia Price List Catalogue 2013 Electrical Distribution, Automation & Control ! %3%%3( 3'33, )3 3%%3( +3&-==33&2/= |
Original | ||||
| zq 700 | Operating instructions Pull-wire emergency-stop switches ZQ 700 1 About this document Operating instructions… pages 1 to 6 EN FR NL JP 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe |
Original | ||||
| Rope operated safety switches for the protection | Rope operated safety switches for the protection of exposed machiner y ■ Lockout mechanism isolates safety contacts until manually reset ■ 12 and 35 metre rope length models ■ Indicator of correct rope tension ■ Fail-safe in the event of slack or broken wire rope |
Original | ||||
| Rope operated safety switches for the protection | Rope operated safety switches for the protection of exposed machiner y ■ Lockout mechanism isolates safety contacts until manually reset ■ 12 and 35 metre rope length models ■ Indicator of correct rope tension ■ Fail-safe in the event of slack or broken wire rope |
Original | ||||