BLOWN FUSE INDICATOR APPLICATIONS Search Results
BLOWN FUSE INDICATOR APPLICATIONS Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TCK301G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK304G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK305G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 | Datasheet | ||
| TCK321G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C | Datasheet | ||
| TCK323G | Toshiba Electronic Devices & Storage Corporation | Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C | Datasheet |
Documents mentioning BLOWN FUSE INDICATOR APPLICATIONS
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 660vdc | 660VDC FERRULE FUSES /SPECIAL PURPOSE SIZE: 27X60 Features/Benefits Ratings ➤ 0.8 to 110 Amps ➤ Full Range D.C. operation ➤ 660VDC at 50kA I.R. 4R=15mSec ➤ 27x60mm ceramic cylindrical body ➤ Blown Fuse indicator striker ➤ Underwriters Recognized component |
Original | ||||
| compact fusion brochure | Line B COMPACT FUSION SCR POWER CONTROLLERS 1 Compact FUSION Brochure Rev 3.50 www.ccipower.com 1-800-765-2799 © Control Concepts Inc., 2013 FEATURES Auto-Ranging Input Voltage 24 - 600 VAC, 45 - 65 Hz AC Output 10 - 160 Amps Internal Class-T Fusing Blown Fuse Indicator |
Original | ||||
| 100ka | 600-750V DC SQUARE-BODY/SPECIAL PURPOSE SIZE: 123 Features/Benefits Ratings CC 7.5gRC 500 Amp ➤ 750vdc@100kA L/R=100mSec ➤ Blown Fuse indicator ➤ 900vdc at 100kA L/R=40mSec ➤ Full range D.C. operation CC 7.5gRB, gRD ➤ 630 to 750 Amp ➤ Dimensions |
Original | ||||
| 750vdc | 750V DC SQUARE-BODY FUSES /SPECIAL PURPOSE SIZE: 120 Features/Benefits Ratings ➤ 50 to 160 Amps ➤ Blown Fuse indicator ➤ 750vdc at 100kA L/R=100mSec ➤ Square ceramic body ➤ 900vdc at 100kA L/R=40mSec ➤ Full range D.C. operation ➤ Bladed and tapped versions |
Original | ||||
| POWR-PRO® Fuses JTD_ID Series Indicator® | POWR-PRO® Fuses JTD_ID Series Indicator® POWR-PRO® Class J Fuses 600 VAC • Time Delay • 8/10 – 600 Amperes Applications POWR-PRO® Fuses Fused combination motor controllers to provide IEC Type 2 (“No Damage”) motor branch circuit short-circuit and ground fault |
Original | ||||
| POWR-PRO® Fuses LLSRK_ID Series Indicator® | POWR-PRO® Fuses LLSRK_ID Series Indicator® POWR-PRO® Class RK1 Fuses 600 VAC • Dual-Element, Time-Delay • 1/10 – 600 Amperes Applications POWR-PRO® Fuses All general purpose circuits Motors Transformers Solenoids Fluorescent lighting |
Original | ||||
| 1264-2012.qxp:QuarkCatalogTempNew 9/4/12 7:00 AM | 1264-2012.qxp:QuarkCatalogTempNew 9/4/12 7:00 AM Page 1264 POWER ENCLOSURES INTERCONNECT TEST & MEASUREMENT 14 Fuse Holders Applications. Marathon Fuse Holders can be used in various applications, including control panels, lighting and heating circuits, motor circuits, circuit breaker protection, switchgear equipment, appliances, electric heat, air conditioning and refrigeration |
Original | ||||
| International Products LPSG Series Global Pro™ | International Products LPSG Series Global Pro™ Fuseholders Applications • Motor control centers Motor branch circuits Primary and secondary protection for transformers Equipment designed for export Features And Benefits The Global Pro Fuseholder also accepts IEC dimension cartridge style |
Original | ||||
| Introducing the Global Pro System Offering World | Introducing the Global Pro System Offering World Class Performance and Global Acceptance The International Challenge The benefits of the Global Pro System include: Engineers and equipment designers are faced with a dilemma when choosing the right circuit protection for their |
Original | ||||
| M 4/8.SF - Up to 10A, 8 mm spacing, with or | M 4/8.SF - Up to 10A, 8 mm spacing, with or without indicator. With or without indicator, the blocks can be ganged for multiple pole operation. A profile matching standard block, M 4/8, allows easy wiring of fuse/line applications. * Blocks with LED indicators are labeled "+" on the outside of the lever. |
Original | ||||
| flsr_id | General Purpose Fuses FLNR_ID/FLSR_ID Indicator® Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay • 1/10 – 600 Amperes Applications General Purpose Fuses Service entrance switches Switchboard main and feeder switches Motor control center mains and motor branch circuits |
Original | ||||
| JTD_ID Series Indicator POWR-PRO® Class J Fuses | JTD_ID Series Indicator POWR-PRO® Class J Fuses 600 VAC ■ Time Delay ■ 8/10 – 600 Amperes POWR-PRO FUSES SPECIFICATIONS Voltage ratings: AC: 600 Volts DC: Contact Factory Interrupting ratings: AC: 200,000 amperes rms symmetrical. 300,000 amperes rms symmetrical |
Original | ||||
| JTD_ID Series Indicator POWR-PRO® Class J Fuses | JTD_ID Series Indicator POWR-PRO® Class J Fuses 600 VAC ■ Time Delay ■ 8/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact Factory Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical (Littelfuse self-certified) |
Original | ||||
| JTD_ID Series Indicator POWR-PRO® Class J Fuses | JTD_ID Series Indicator POWR-PRO® Class J Fuses 600 VAC ■ Time Delay ■ 8/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact Factory Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical (Littelfuse self-certified) |
Original | ||||
|
|
||||||
| POWR-PRO® Fuses IDSR Series Indicator® POWR-PRO® | POWR-PRO® Fuses IDSR Series Indicator® POWR-PRO® Class RK5 Fuse 600 V AC/DC • Time-Delay • 1/10 – 600 Amperes POWR-PRO® Fuses Money is wasted each time a circuit opens and halts production. The indicator window of the IDSR allows maintenance personnel to |
Original | ||||
| POWR-PRO® Fuses IDSR Series Indicator® POWR-PRO® | POWR-PRO® Fuses IDSR Series Indicator® POWR-PRO® Class RK5 Fuse 600 V AC/DC • Time-Delay • 1/10 – 600 Amperes POWR-PRO® Fuses Money is wasted each time a circuit opens and halts production. The indicator window of the IDSR allows maintenance personnel to |
Original | ||||
| Low Voltage Fuses General information Description | Low Voltage Fuses General information Description FUJI low voltage current-limiting fuses are designed to give protection to power supply and distribution circuits and equipment such as motor starter and semiconductors. Since they can be supplied in a variety |
Original | ||||
| ad8557 | Digitally Programmable Sensor Signal Amplifier AD8557 Preliminary Technical Data FEATURES APPLICATIONS Very low offset voltage: 10 μV max over temperature Very low input offset voltage drift: 50 nV/°C max High CMRR: 96 dB min Digitally programmable gain and output offset voltage |
Original | ||||
| LLSRK_ID Series IndicatorTM POWR-PRO® Class RK1 | LLSRK_ID Series IndicatorTM POWR-PRO® Class RK1 600 VAC ■ Dual-Element, Time-Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage Rating: 600 VAC/300 VDC Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical (Littelfuse self-certified) |
Original | ||||
| 6,9 gRB-URB DIN German Standard German Standard | 6,9 gRB-URB DIN German Standard German Standard 500 - 690V AC gRB-URB FROM 20 TO 400A Size: 000 Features/Benefits: •• Extremely high interrupting rating •• Protection of power semiconductors according to IEC 269.1 and EN 60269.4 •• 500-690V [Rating 20 to 400A] |
Original | ||||
| t duc Pro ilable m ava ng fro ti star 2009 System | t duc Pro ilable m ava ng fro ti star 2009 System Selection tables ® pro M compact Protection devices E 90 fuse-disconnectors E 90 E 90 fuse-disconnectors 2CSC400696F0201 E 90 series fuse-disconnectors are designed for connecting and disconnecting circuits under load, providing |
Original | ||||
| PREVIOUS HOME NEXT FIND IT CYLINDER Cylinder | PREVIOUS HOME NEXT FIND IT CYLINDER Cylinder Fuses are typically used in industrial applications to protect electrical devices such as motors, drives, etc. They are available in four sizes with a current range from 1 to 125 Amps. Cylinder Fuses have metal caps at both |
Original | ||||