    PEF24628EV1X
    Rochester Electronics LLC PEF24628 - SOCRATES Four-channel SHDSL EFM system-on-chip PDF Buy
    TCK305G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK321G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 36 V, 2.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP16C Datasheet
    TCK304G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet
    TCK301G
    Toshiba Electronic Devices & Storage Corporation Load Switch IC, 2.3 to 28 V, 3.0 A, Inrush current reducing / Reverse current blocking / Flag indicate, WCSP9 Datasheet

    BLOWN FUSE INDICATOR APPLICATIONS Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Compact FUSION Brochure

    Contextual Info: Line B COMPACT FUSION SCR POWER CONTROLLERS 1 Compact FUSION Brochure Rev 3.50 www.ccipower.com 1-800-765-2799 Control Concepts Inc., 2013 FEATURES Auto-Ranging Input Voltage 24 - 600 VAC, 45 - 65 Hz AC Output 10 - 160 Amps Internal Class-T Fusing Blown Fuse Indicator


    Original
    RS-485) SMAFUSION-RD25) Compact FUSION Brochure PDF

    D310020

    Abstract: M085203 B0904 N085204 MC 3E 1-5N C090438 L089388 ttf 103 B087332 900VDC
    Contextual Info: 750V DC SQUARE-BODY FUSES /SPECIAL PURPOSE SIZE: 120 Features/Benefits Ratings ➤ 50 to 160 Amps ➤ Blown Fuse indicator ➤ 750vdc at 100kA L/R=100mSec ➤ Square ceramic body ➤ 900vdc at 100kA L/R=40mSec ➤ Full range D.C. operation ➤ Bladed and tapped versions


    Original
    750vdc 100kA 100mSec 900vdc 40mSec 100ms D310020 M085203 B0904 N085204 MC 3E 1-5N C090438 L089388 ttf 103 B087332 PDF

    FU520

    Abstract: 115 663.23 29013 RC510 RC65 FEM8S FU525 115 661.21
    Contextual Info: M 4/8.SF - Up to 10A, 8 mm spacing, with or without indicator. With or without indicator, the blocks can be ganged for multiple pole operation. A profile matching standard block, M 4/8, allows easy wiring of fuse/line applications. * Blocks with LED indicators are labeled "+" on the outside of the lever.


    Original
    FU520 FU525 RC810 RC610 RC510 FU520 115 663.23 29013 RC510 RC65 FEM8S FU525 115 661.21 PDF

    Littelfuse 16A 250v fuse

    Abstract: FLSR100ID LR250 LR29862 LR600 Littelfuse FLNR 30 6002F FLSR_ID FLS-R-10
    Contextual Info: General Purpose Fuses FLNR_ID/FLSR_ID Indicator Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay • 1/10 – 600 Amperes Applications General Purpose Fuses Service entrance switches Switchboard main and feeder switches Motor control center mains and motor branch circuits


    Original
    PDF

    blown fuse indicator APPLICATIONS

    Abstract: LR29862 jtd 100 id
    Contextual Info: JTD_ID Series Indicator POWR-PRO Class J Fuses 600 VAC • Time Delay ■ 8/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 600 Volts DC: Contact Factory Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical Littelfuse self-certified


    Original
    E81895) LR29862) blown fuse indicator APPLICATIONS LR29862 jtd 100 id PDF

    blown fuse indicator APPLICATIONS

    Abstract: of blown fuse indicator LR29862 LR600 E81895 FLSR_ID
    Contextual Info: POWR-PRO Fuses IDSR Series Indicator® POWR-PRO® Class RK5 Fuse 600 V AC/DC • Time-Delay • 1/10 – 600 Amperes POWR-PRO® Fuses Money is wasted each time a circuit opens and halts production. The indicator window of the IDSR allows maintenance personnel to


    Original
    LR600 blown fuse indicator APPLICATIONS of blown fuse indicator LR29862 E81895 FLSR_ID PDF

    blown fuse indicator APPLICATIONS

    Abstract: 200 Amp Fuse of blown fuse indicator LR600 blown fuse indicator LLSRK30ID LR29862 250 amp fuse 60 amp fuse
    Contextual Info: LLSRK_ID Series IndicatorTM POWR-PRO Class RK1 600 VAC • Dual-Element, Time-Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage Rating: 600 VAC/300 VDC Interrupting Ratings: AC: 200,000 amperes rms symmetrical 300,000 amperes rms symmetrical Littelfuse self-certified


    Original
    VAC/300 E81895) LR29862) blown fuse indicator APPLICATIONS 200 Amp Fuse of blown fuse indicator LR600 blown fuse indicator LLSRK30ID LR29862 250 amp fuse 60 amp fuse PDF

    NFC 63210

    Abstract: SCR 30A 500V IEC 269 63210 NFC 63210 22x58 63211 32A-100A CB832 20C10x38SC 14X51
    Contextual Info: PREVIOUS HOME NEXT FIND IT CYLINDER Cylinder Fuses are typically used in industrial applications to protect electrical devices such as motors, drives, etc. They are available in four sizes with a current range from 1 to 125 Amps. Cylinder Fuses have metal caps at both


    Original
    CB2258-1 CB2258-1N CB2258-2 CB2258-3 CB2258-3N NFC 63210 SCR 30A 500V IEC 269 63210 NFC 63210 22x58 63211 32A-100A CB832 20C10x38SC 14X51 PDF

    AD8556

    Abstract: datasheet of blown fuse indicator
    Contextual Info: Digitally Programmable Sensor Signal Amplifier with EMI Filters AD8556 FEATURES APPLICATIONS EMI filters at input pins Specified from −40°C to +140°C Low offset voltage: 10 µV max Low input offset voltage drift: 65 nV/°C max High CMRR: 94 dB min Digitally programmable gain and output offset voltage


    Original
    AD8556 AD8556ARZ1 AD8556ARZ-REEL1 AD8556ARZ-REEL71 AD8556ACPZ-R21 AD8556ACPZ-REEL1 AD8556ACPZ-REEL71 AD8556ARZ-EVAL1 16-Lead AD8556 datasheet of blown fuse indicator PDF

    AD8557

    Abstract: AD8557ACPZ-R2 AD8557ACPZ-REEL AD8557ACPZ-REEL7 AD8557ARZ MO-220-VGGC MS-012-AA polyfuse* ac
    Contextual Info: Digitally Programmable Sensor Signal Amplifier AD8557 FEATURES APPLICATIONS Automotive sensors Pressure and position sensors Precision current sensing Thermocouple amplifiers Industrial weigh scales Strain gages FUNCTIONAL BLOCK DIAGRAM VDD VCLAMP VDD A4 VNEG


    Original
    AD8557 D06013-0-6/11 AD8557 AD8557ACPZ-R2 AD8557ACPZ-REEL AD8557ACPZ-REEL7 AD8557ARZ MO-220-VGGC MS-012-AA polyfuse* ac PDF

    Z330026

    Abstract: R3301 R330042 C330029 C220710 N330039 y330025 S330181 R330019 W330184
    Contextual Info: DIN 000 FUSES 6,9 gRB-URB SEMICONDUCTOR PROTECTION FUSES GERMAN STANDARD 500 - 690 V AC gRB-URB FROM 20 TO 400A SIZE: 000 Features / Benefits ➤ Extremely high Interrupting rating Fuses: Protection of power Semiconductors according to269.1 and 4 ➤ 500-690V Voltage Rating [Rating 20 to 400A]


    Original
    to269 00-690V 43653-00C Z330026 R3301 R330042 C330029 C220710 N330039 y330025 S330181 R330019 W330184 PDF

    AD8557

    Abstract: Digital Weighing Scale schematic AD8557ACPZ-R2 AD8557ACPZ-REEL AD8557ACPZ-REEL7 AD8557ARZ MO-220-VGGC MS-012-AA
    Contextual Info: Digitally Programmable Sensor Signal Amplifier AD8557 FEATURES APPLICATIONS Automotive sensors Pressure and position sensors Precision current sensing Thermocouple amplifiers Industrial weigh scales Strain gages FUNCTIONAL BLOCK DIAGRAM VDD VCLAMP VDD A4 VNEG


    Original
    AD8557 D06013-0-7/10 AD8557 Digital Weighing Scale schematic AD8557ACPZ-R2 AD8557ACPZ-REEL AD8557ACPZ-REEL7 AD8557ARZ MO-220-VGGC MS-012-AA PDF

    K216669J

    Abstract: D218204J FR22AM69V40P R211569J
    Contextual Info: Modulostar aM 8.5 x 31,5 - 400V Size Current Voltage A (V) 8,5 x 31,5 1 8,5 x 31,5 2 8,5 x 31,5 4 8,5 x 31,5 6 8,5 x 31,5 8 8,5 x 31,5 10 8,5 x 31,5 Neutral 400 400 400 400 400 400 Cat.number w/o indicator FR8AM40V1 FR8AM40V2 FR8AM40V4 FR8AM40V6 FR8AM40V8


    Original
    FR8AM40V1 FR8AM40V2 FR8AM40V4 FR8AM40V6 FR8AM40V8 FR8AM40V10 FRN832 C217168J R218193J S219229J K216669J D218204J FR22AM69V40P R211569J PDF

    A072F

    Abstract: A480R5R-1HE A480R6R-1 A072F1DORO-6R A072B2DARO-18R A480R9R-1 A072F1DORO-9R A480R12R-1 A240R A072F1DORO-3R
    Contextual Info: AMP-TRAP A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of medium voltage motors and motor controllers. R-rated fuses are back up fuses that


    Original
    A240R/A480R/A072F/A072B A480R) A072F) A072F/A072B A072F A072B, A072F2 A480R5R-1HE A480R6R-1 A072F1DORO-6R A072B2DARO-18R A480R9R-1 A072F1DORO-9R A480R12R-1 A240R A072F1DORO-3R PDF

    Littelfuse FLNR 30

    Abstract: FLSR_ID FLSR100ID LR600 LR250 LR29862 250 volt to 600 volt fuse
    Contextual Info: FLNR_ID/FLSR_ID IndicatorTM Class RK5 Fuses 250/600 VAC • Dual-Element, Time Delay ■ 1/10 – 600 Amperes SPECIFICATIONS Voltage Ratings: AC: 250 Volts FLNR_ID ; 600 Volts (FLSR_ID) DC: 125 Volts (FLNR 1/10 – 30A); 125 Volts (FLNR_ID 35 – 600A); 300 Volts (FLSR_ID)


    Original
    E81895) LR29862) WF-1814 Littelfuse FLNR 30 FLSR_ID FLSR100ID LR600 LR250 LR29862 250 volt to 600 volt fuse PDF

    2002-403

    Contextual Info: ? Fuse Terminal Blocks for Blade-Type Fuses acc. to DIN 72581-3f, ISO 8820-3, Series 2002​ mm2​ ➊ AWG 22 — 12​ Terminal block width 5.2 mm / 0.205 in​ L 10 — 12 mm / 0.43 in​ 0.25 — 2.5 4 400 V/6 kV/3 IN 10 A​➋ 29 mm2​ ➊ AWG 22 — 12​


    Original
    72581-3f, 2002-403 PDF

    CLASS J blown fuse indicator

    Abstract: of blown fuse indicator E71611
    Contextual Info: LgD Series Global ProTM-tection Fuses 600 Volts AC • GlobalPro Time-Delay ■ 1 – 100 Amperes GLOBAL CIRCUIT PROTECTION SPECIFICATIONS Voltage Ratings: 600 Volts AC UL 690 Volts AC (IEC) Interrupting Rating: AC: 200,000 amperes rms symmetrical Ampere Range: 1 – 100* amperes


    Original
    E71611) LR29862) CLASS J blown fuse indicator of blown fuse indicator E71611 PDF

    gfn20

    Abstract: fuse 10KA GFN3 GFN30 GFN4 blown fuse indicator APPLICATIONS
    Contextual Info: GFN 1-1/2” X 13/32” GFN midget indicating fuses are available in 34 ratings from 1/10A through 30A. These time-delay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually indicate when the fuse has operated to open the


    Original
    1/10A GFN1/10 GFN15/10 GFN2/10 GFN3/10 GFN4/10 GFN6/10 GFN8/10 GFN1-4/10 GFN1-6/10 gfn20 fuse 10KA GFN3 GFN30 GFN4 blown fuse indicator APPLICATIONS PDF

    Contextual Info: SRM Safety Relay Module Demand Moore Reliability September 2014 Description Part of Moore Industries’ FS FUNCTIONAL SAFETY SERIES, the SRM Safety Relay Module provides a high level of availability for safety-critical applications and as a part of Safety Instrumented Systems SIS .


    Original
    PDF

    WESTINGHOUSE ELECTRIC fuse

    Abstract: A055F1D westinghouse transformer WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A bussmann Fuse 40a A055F1 a055f2doro westinghouse kV transformer MV055F1CAX15E MV055F1CAX20E
    Contextual Info: Bussmann E-Rated Medium Voltage Fuses MV055 For Transformer and Feeder Protection 5.5 kV Electrical Characteristics Part Number † Ampere Rating Min. Melt I2t Max. Clear I2t MV055F1CAX5E 5A 180 2400 MV055F1CAX7E 7A 850 8000 MV055F1CAX10E 10A 850 8000 MV055F1CAX15E


    Original
    MV055 MV055F1CAX5E MV055F1CAX7E MV055F1CAX10E MV055F1CAX15E MV055F1CAX20E MV055F1CAX25E MV055F1CAX30E MV055F1CAX40E MV055F1CAX50E WESTINGHOUSE ELECTRIC fuse A055F1D westinghouse transformer WESTINGHOUSE ELECTRIC fuse MEDIUM VOLTAGE 100A bussmann Fuse 40a A055F1 a055f2doro westinghouse kV transformer MV055F1CAX15E MV055F1CAX20E PDF

    AD8556

    Abstract: AD8556ACPZ-R2
    Contextual Info: FUNCTIONAL BLOCK DIAGRAM FEATURES EMI filters at input pins Specified from −40°C to +140°C Very low offset voltage: 11 µV maximum over temperature Very low input offset voltage drift: 65 nV/°C maximum High CMRR: 94 dB minimum Digitally programmable gain and output offset voltage


    Original
    AD8556 CP-16-4) AD8556ARZ1 AD8556ARZ-REEL71 AD8556ARZ-REEL1 AD8556ARZ-EVAL1 AD8556ACPZ-R21 AD8556ACPZ-REEL71 AD8556ACPZ-REEL1 16-Lead AD8556 AD8556ACPZ-R2 PDF

    AD8557

    Abstract: AD8557ACPZ-R2 MO-220-VGGC AD8557AR-EVAL
    Contextual Info: Digitally Programmable Sensor Signal Amplifier AD8557 auto-zero and DigiTrim technologies to create an accurate and flexible signal processing solution in a compact footprint. FEATURES Very low offset voltage: 12 V maximum over temperature Very low input offset voltage drift: 65 nV/°C maximum


    Original
    AD8557 57ACPZ-REEL1 AD8557ACPZ-REEL71 AD8557ARZ1 AD8557ARZ-REEL1 AD8557ARZ-REEL71 AD8557AR-EVAL 16-Lead AD8557 AD8557ACPZ-R2 MO-220-VGGC AD8557AR-EVAL PDF

    ferraz gS

    Abstract: blown fuse indicator APPLICATIONS ferraz 14 50 ferraz
    Contextual Info: FERRAZ PRODUCT DATA FC-GP-6JX JULY 1997 Publication: High Performance Midget Fuses - 6 JX Series K600470-07/97 RA 0312B 600 Volts AC/500 Volts DC 100,000A I.R. 100 mA TO 30 Amps Current Limiting The Ferraz 6JX M idget Fuses are recom m ended for applications


    OCR Scan
    K600470-07/97 0312B AC/500 100mA 125mA 300mA 750mA 100mA-1A 1X514 ferraz gS blown fuse indicator APPLICATIONS ferraz 14 50 ferraz PDF

    LA30QS800

    Abstract: LA30QS800-4 LA30QS450-4 LA30QS60-4 la scr catalog blown fuse indicator APPLICATIONS LA30QS250-4TI
    Contextual Info: LA30QS Semiconductor Fuses 300 VAC • Very Fast-Acting ■ 35 – 4500 Amperes SPECIFICATIONS Voltage Rating: AC: 300 volts DC: 300 volts Interrupting Rating: 200,000 Amperes Ampere Range: 35 – 4500 Amperes Approvals: UL Recognized under the components


    Original
    LA30QS LA30QS800 LA30QS800-4 LA30QS450-4 LA30QS60-4 la scr catalog blown fuse indicator APPLICATIONS LA30QS250-4TI PDF