| balco | PRECISION SENSING ELEMENT TYPE PT "Profit from PRECISION” BALCO® sensing element: • Type PT156 1000 ohm sensor is the ultimate in Balco technology with resistance tolerances to ±0.05% . • TCR char: +4300ppm/°C (±50ppm/°C) between 25°C and 100°C. |
OCR Scan | ||||
| balco | 100 Series / SM Series / PC Series Precision Wirewound Resistors • Resistances to 6 Megohms Resistance Tolerances to ±0.005% Temperature Coefficients of ±1 ppm/K High TCR Available (Balco & Platinum Wire) 100% Acceptance Tested / Traceable to NIST |
Original | ||||
| PRECISION SENSING ELEMENT TY PE FT _ . _ j _ Type | PRECISION SENSING ELEMENT TY PE FT _ . _ j _ Type PT156 1 Kilohm ±1% BALCO® sensing elements are in-stock for immediate delivery. L-*H _______________ Custom resistance tolerances to ±0.05% with: • TCR char: +4300ppm/°C (±50ppm/°C) between 25°C and 100°C. |
OCR Scan | ||||
| Bondable Resistor Patterns Micro-Measurements | Bondable Resistor Patterns Micro-Measurements Bondable Resistors for Transducers – Selection Chart GAGE PATTERN AND DESIGNATION Matrix is shown at actual size. Insert Desired S-T-C No. in Spaces Marked XX. See Note 1 N2B-TR-A02-00150 N2B-TR-A02-00175 N2B-TR-A02-00200 |
Original | ||||
| TRANSDUCER STRAIN GAGE ACCESSORIES SPAN | TRANSDUCER STRAIN GAGE ACCESSORIES SPAN TEMPERATURE COMPENSATION RESISTOR SPECIFICATIONS NICKEL MODULUS SPAN TEMPERATURE COMPENSATION RESISTORS Tolerance in Ohms: ±1 ohms Temp. Coefficient of Resistance: 0.59%/°C (0.33%/°F) Temp. Range:10 to 65°C (50 to 150°F) |
Original | ||||
| rtd basics | RTD Basics Why Choose Riedon (a Resistor Company) For Your Special RTD Requirements Riedon has manufactured high-precision wirewound resistors for OEM industries since 1960. These precision resistors have tolerances as small as 0.005%. They are extremely stable over time, and operate over wide operating |
Original | ||||
| temperature sensing wirewound resistors | Temperature Sensing Wirewound Resistors • Standard TCRs available to 6000ppm/K Engineering assistance available for application support Custom TCRs developed for special applications Customized packages available Short Lead Times on samples and stock TCRs |
Original | ||||
| resistor catalog | RESISTOR CATALOG HANDBOOK 2004 ENGINEERS & DESIGNERS! PRC can save you both Time and Money when you need “Custom High Quality” Precision Fixed Wire Wound… RESISTORS SENSORS AND SHUNTS PRC PRECISION RESISTOR CO., INC. 10601 75th Street North, Largo, FL 33777-1421 U.S.A. |
Original | ||||
| VISHAY INTERTECHNO L O G Y , INC . INTERACTIVE | VISHAY INTERTECHNO L O G Y , INC . INTERACTIVE data book transducer-class ® strain gages vishay micro-measurements vse-db0075-0802 Notes: 1. To navigate: a) Click on the Vishay logo on any datasheet to go to the Contents page for that section. Click on the Vishay logo on any Contents |
Original | ||||
| ax400 | PROFIBUS® Datalink Description Supplement IM/AX4/PBS Issue 3 Single and Dual Input Analyzers AX400 Series ABB The Company EN ISO 9001:1994 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. |
Original | ||||
| ax416 | User Guide IM/AX4PH Issue 12 Single and Dual Input Analyzers for pH/Redox (ORP) AX416, AX436, AX460, AX466 & AX468 ABB The Company EN ISO 9001:2000 We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental |
Original | ||||
| TAC I/A Series 1 MicroNet BACnet VAV Controllers | TAC I/A Series 1 MicroNet BACnet VAV Controllers MicroNet BACnet VAV Controllers MNB-Vx The TAC I/A Series™ MicroNet™ BACnet™ VAV (Variable Air Volume) Controllers are interoperable controllers with native BACnet MS/TP communications support. All models incorporate: an |
Original | ||||
| STR AIN Getting the Most out of Strain Gauge Load | STR AIN Getting the Most out of Strain Gauge Load Cells Optimized performance is the result of a blend of good manufacturing processes, smart system integration, high-dynamic range A/D converters, and software compensation. ou’ve heard of strain gauge load cells. You may have even seen one or two. But do you know |
Original | ||||
| Electric/Electronic Products Catalog Make the | Electric/Electronic Products Catalog Make the most of your energy General Information TAC TAC is a Schneider Electric Company with a long tradition of global leadership in building controls technology. We offer the most extensive line of controls and components available to today's market, including: valve bodies, valve assemblies, actuation devices and sensors, as well as interfaces, and automated systems that link these products and other building systems |
Original | ||||
|
|
||||||
| adt70 | a PRTD Conditioning Circuit and Temperature Controller ADT70/ADT71* Preliminary FEATURES PRTD Temperature Measurement Range Typically IC Measurement Error ±0.1°C Includes Two Matched Current Sources Rail-to-Rail Output Instrumentation Amp Uncommitted, Rail-to-Rail Output, Op Amp |
Original | ||||
| adt70 | BACK a PRTD Conditioning Circuit and Temperature Controller ADT70/ADT71* Preliminary FEATURES PRTD Temperature Measurement Range Typically IC Measurement Error ±0.1°C Includes Two Matched Current Sources Rail-to-Rail Output Instrumentation Amp Uncommitted, Rail-to-Rail Output, Op Amp |
Original | ||||
| THE THERMISTOR 12 .390 .344 .293 8 Equivalent | THE THERMISTOR 12 .390 .344 .293 8 Equivalent Linearities Type S Thermocouple vs. Platinum RTD 4 200 400 600 Like the RTD, the thermistor is also a temperature sensitive resistor. While the thermocouple is the most versatile temperature transducer and the PRTD is the |
Original | ||||
| Application Notes Resistor Selection RESISTOR | Application Notes Resistor Selection RESISTOR FACTS AND FACTORS A resistor is a device connected into an electrical circuit to introduce a specified resistance. The resistance is measured in ohms. As stated by Ohm’s Law, the current through the resistor |
Original | ||||
| Application Notes Resistor Selection RESISTOR | Application Notes Resistor Selection RESISTOR FACTS AND FACTORS A resistor is a device connected into an electrical circuit to introduce a specified resistance. The resistance is measured in ohms. As stated by Ohm’s Law, the current through the resistor |
Original | ||||