Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    B8806 Search Results

    B8806 Datasheets (478)

    Select Manufacturer
    Part ECAD Model Manufacturer Description Datasheet Type PDF PDF Size Page count
    B88069X0180S102
    EPCOS Arrester: Surge Arrester 2-Electrode-Arrester: Tape and Reel Original PDF 80.12KB 2
    B88069X0180T502
    EPCOS Arrester: Surge Arrester 2-Electrode-Arrester: Tape and Reel Original PDF 80.12KB 2
    B88069X0190S102
    EPCOS IC SURGE ARRESTER Original PDF 79.43KB 2
    B88069X0190T502
    EPCOS IC SURGE ARRESTER Original PDF 79.43KB 2
    B88069X0200S102
    EPCOS 2-Electrode-Arrester Original PDF 78.14KB 2
    B88069X0210S102
    EPCOS Switching Spark Gap Original PDF 80.31KB 2
    B88069X0240S102
    EPCOS Circuit Protection - Gas Discharge Tube Arresters (GDT) - GAS DISCHARGE TUBE Original PDF 89.78KB
    B88069X0250S102
    EPCOS IC Switching Spark Gaps Original PDF 90.35KB 3
    B88069X0260S102
    EPCOS Switching Spark Gap Original PDF 87.73KB 2
    B88069X0260T502
    EPCOS - TDK Electronics GDT SPARK GAP SSG3X-1 Original PDF 51.39KB 5
    B88069X0270S102
    EPCOS Switching Spark Gap Original PDF 88.17KB 2
    B88069X0280T502
    EPCOS IC SWITCHING SPARK GAP T/R Original PDF 23.5KB 3
    B88069X0340T103
    EPCOS Switching Spark Gap Original PDF 88.84KB 2
    B88069X0340T502
    EPCOS Circuit Protection - Gas Discharge Tube Arresters (GDT) - GDT 800V THROUGH HOLE Original PDF 63.13KB
    B88069X0400S102
    EPCOS Circuit Protection - Gas Discharge Tube Arresters (GDT) - FS04X-1JM Original PDF 86.43KB
    B88069X0410T502
    EPCOS Switching Spark Gap Original PDF 89.49KB 2
    B88069X0440S102
    EPCOS IC ELECTRODE ARRESTER Original PDF 73.5KB 2
    B88069X0450C253
    EPCOS 2-Electrode-Arrester Original PDF 80.45KB 2
    B88069X0540B103
    EPCOS Circuit Protection - Gas Discharge Tube Arresters (GDT) - 2 ELECT / 90V Original PDF 23.88KB
    B88069X0540C103
    EPCOS Circuit Protection - Gas Discharge Tube Arresters (GDT) - EC 90XN Original PDF 85.33KB
    ...
    SF Impression Pixel

    B8806 Price and Stock

    TDK Corporation

    TDK Corporation B88069X720S102

    Arrester: surge arrester; THT; Ubr type: 90V; Uimp max: 450V; 8mm
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME B88069X720S102 13,200 200
    • 1 -
    • 10 -
    • 100 -
    • 1000 $0.55
    • 10000 $0.55
    Buy Now
    Avnet Abacus B88069X720S102 13,800 23 Weeks 100
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Buy Now

    TDK Corporation B88069X1630T602

    Arrester: surge arrester; SMD; Ø8x6mm; Ubr type: 90V; 1.5pF; 10GΩ
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME B88069X1630T602 496 1
    • 1 $2.17
    • 10 $2.17
    • 100 $1.49
    • 1000 $1.02
    • 10000 $0.77
    Buy Now
    Avnet Asia B88069X1630T602 26 Weeks 600
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    TDK Corporation B88069X0720S102

    Arrester: surge arrester; Ubr type: 90V; Uimp max: 550V; Ø: 8mm; 1pF
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME B88069X0720S102 382 1
    • 1 $1.42
    • 10 $1.30
    • 100 $0.86
    • 1000 $0.73
    • 10000 $0.73
    Buy Now
    TTI B88069X0720S102 Ammo Pack 2,250 50
    • 1 -
    • 10 -
    • 100 $0.91
    • 1000 $0.91
    • 10000 $0.91
    Buy Now

    TDK Corporation B88069X6461S102

    Arrester: surge arrester; Ubr type: 600V; Uimp max: 850V; Ø: 8mm
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME B88069X6461S102 349 1
    • 1 $2.24
    • 10 $1.70
    • 100 $1.42
    • 1000 $1.41
    • 10000 $1.41
    Buy Now

    TDK Corporation B88069X4880S102

    Arrester: surge arrester; Ubr type: 90V; Uimp max: 550V; Ø: 8mm
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    TME B88069X4880S102 147 1
    • 1 $1.52
    • 10 $1.35
    • 100 $0.95
    • 1000 $0.84
    • 10000 $0.84
    Buy Now
    Avnet Asia B88069X4880S102 20 Weeks 1,000
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    Documents mentioning B8806

    Document Partial File Text Tags Type PDF
    em4500xs
    Surge arrester 2-electrode arrester Series/Type: Ordering code: EM4500XS B88069X9271**** Version/Date: Version: Issue 01 / 2010-05-04 6 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
    Original PDF
    g30-a90xsmd
    Surge arrester 2-electrode arrester Series/Type: Ordering code: G30-A90XSMD B88069X9451T203 Version/Date: Version: Issue 02 / 2010-11-15 6 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
    Original PDF
    em400x
    Surge Arrester 2-Electrode-Arrester EM400X Ordering code: B88069X0200S102 DC spark-over voltage 1) 2) 400 ± 20 V % < 800 < 750 V V < 900 < 850 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 2.5 5 kA
    Original PDF
    t87-a230x
    Surge Arrester 3-Electrode-Arrester T87-A230X Ordering code: B88069X8900B502 DC spark-over voltage 1) 2) 4) 230 ± 20 V % < 450 < 400 V V < 650 < 600 V V Nominal impulse discharge current (wave 8/20 µs) 5) Single impulse discharge current (wave 8/20 µs) 5)
    Original PDF
    fs04x-1jmg
    Switching Spark Gap FS04X-1JMG Ordering code: B88069X0410T502 Nominal breakdown voltage VN Initial values Static breakdown voltage VS 1) 2) First ignition value VS, FTE after 24 hours in darkness Following ignition values (selection limits) Following ignition values VS, FIV
    Original PDF
    a71-h10x
    Surge Arrester 2-Electrode-Arrester A71-H10X Ordering code: B88069X3820S102 DC spark-over voltage 1) 2) 1000 ± 15 V % < 1300 < 1200 V V < 1400 < 1300 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 10
    Original PDF
    em4000
    Surge Arrester 2-Electrode-Arrester EM4000XS Ordering code: B88069X4251xxxx a) DC spark-over voltage 1) 2) 4000 ± 20 V % < 4800 < 4000 V V < 4900 < 4100 V V 2 100 kA A Insulation resistance at 100 Vdc >1 GΩ Capacitance at 1 MHz <1 pF Arc voltage at 1 A
    Original PDF
    v12-h14x
    Surge Arrester 2-Electrode-Arrester V12-H14X Ordering code: B88069X4220C101 DC spark-over voltage 1) 2) 1400 ± 20 V % < 1900 < 1800 V V < 2200 < 2000 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20
    Original PDF
    t80-a90x
    Surge Arrester 3-Electrode-Arrester T80-A90X Ordering code: B88069X8360C203 DC spark-over voltage 1) 2) 4) 90 ± 20 V % < 400 < 300 V V < 550 < 450 V V Nominal impulse discharge current (wave 8/20 µs) 5) Single impulse discharge current (wave 8/20 µs) 5)
    Original PDF
    n80-a600x
    Surge Arrester 2-Electrode-Arrester N80-A600X Ordering code: B88069X4990C103 DC spark-over voltage 1) 2) 600 ± 20 V % < 1100 < 950 V V < 1400 < 1100 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 10
    Original PDF
    spark gap
    Switching Spark Gap CAS04XG Ordering code: B88069X1200T502 Preliminary data DC spark-over voltage 1) 2) 350… 550 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 900 < 800 V V < 1200 < 1100 V V Insulation resistance at 300 Vdc
    Original PDF
    spark gap
    Switching Spark Gap FS06X-1NG Ordering code: B88069X3660T502 Nominal breakdown voltage VN 600 V Initial values 2) Static breakdown voltage VS 1) First ignition value VS, FTE after 24 hours in darkness Following ignition values VS, FIV ≤ 720 560… 680 V
    Original PDF
    m51-a600x
    Surge Arrester 2-Electrode-Arrester M51-A600X Ordering code: B88069X4590C102 DC spark-over voltage 1) 2) 570 … 780 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1350 < 1200 V V < 1500 < 1350 V
    Original PDF
    surge arrester
    Surge Arrester 2-Electrode-Arrester V10-H08X Ordering code: B88069X9170C251 DC spark-over voltage 1) 2) 800 ± 20 V % < 1000 < 900 V V < 1200 < 1100 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20 30
    Original PDF
    t80-a230xfp
    Surge Arrester 3-Electrode-Arrester T80-A230XFP Ordering code: B88069X8220B502 DC spark-over voltage 1) 2) 4) 230 ± 20 V % < 450 < 400 V V < 650 < 600 V V Nominal impulse discharge current (wave 8/20 µs) 5) Single impulse discharge current (wave 8/20 µs) 5)
    Original PDF
    em300x
    Surge Arrester 2-Electrode-Arrester EM300X Ordering code: B88069X0800xxxx a) DC spark-over voltage 1) 2) 270 … 345 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 700 < 600 V V < 800 < 700 V V Nominal impulse discharge current (wave 8/20 µs)
    Original PDF
    t83-a260xf4
    Surge Arrester 3-Electrode-Arrester T83-A260XF4 Ordering code: B88069X7170B502 DC spark-over voltage 1) 2) 4) 260 ± 20 V % < 500 < 450 V V < 700 < 650 V V Nominal impulse discharge current (wave 8/20 µs) 5) Single impulse discharge current (wave 8/20 µs) 5)
    Original PDF
    em550x
    Surge Arrester 2-Electrode-Arrester EM550X Ordering code: B88069X2910S102 DC spark-over voltage 1) 2) 550 ± 20 V % < 1000 < 850 V V < 1100 < 950 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 2.5 5 kA
    Original PDF
    a81-c90xg
    Surge Arrester 2-Electrode-Arrester A81-C90XG Ordering code: B88069X3840T502 DC spark-over voltage 1) 2) 90 ± 20 V % < 500 < 450 V V < 600 < 550 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 20 25 kA
    Original PDF
    a80-c90x
    Surge Arrester 2-Electrode-Arrester A80-C90X Ordering code: B88069X1410C103 DC spark-over voltage 1) 2) 90 ± 20 V % < 500 < 450 V V < 600 < 550 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) Single impulse discharge current
    Original PDF
    a71-h55x
    Surge Arrester 2-Electrode-Arrester A71-H55X Ordering code: B88069X2620S102 DC spark-over voltage 1) 2) 5500 ± 15 V % < 6500 < 6000 V V < 7000 < 6500 V V Nominal impulse discharge current (wave 8/20 µs) Single impulse discharge current (wave 8/20 µs) 5
    Original PDF