AXIC Search Results
AXIC Datasheets (2)
Axicom
| Part | ECAD Model | Manufacturer | Description | Datasheet Type | PDF Size | Page count | |
|---|---|---|---|---|---|---|---|
| MT2 | Axicom | MT Relay Light Duty dual-in-line | Original | 239.41KB | 8 | ||
| MT4 | Axicom | MT Relay Light Duty dual-in-line | Original | 239.41KB | 8 |
AXIC Price and Stock
Select Manufacturer
Amphenol Corporation 470-AAXI-C- Bulk (Alt: 470-AAXI-C) |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
470-AAXI-C | Bulk | 2 Weeks | 50 |
|
Buy Now | |||||
|
470-AAXI-C |
|
Get Quote | ||||||||
Phoenix Contact 2203165 (HCS-C MAXI C C C C 7035)ELECTRONIC HSG HANDHELD MAXI;HCS-C MAXI C C C C 7035 |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
2203165 (HCS-C MAXI C C C C 7035) | Bulk | 1 |
|
Get Quote | ||||||
TE Connectivity 9-1462038-9High Frequency / RF Relays IM03DGR=IM RELAY 140MW 5V |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
9-1462038-9 | Reel | 27,000 | 1,000 |
|
Buy Now | |||||
TE Connectivity IM03GRHigh Frequency / RF Relays IM03GR=IM RELAY 140MW 5V |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
IM03GR | Reel | 18,000 | 1,000 |
|
Buy Now | |||||
TE Connectivity IM06GRLow Signal Relays - PCB IM06GR=IM RELAY 140MW 12V |
|||||||||||
| Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
|
IM06GR | Reel | 14,000 | 1,000 |
|
Buy Now | |||||
Documents mentioning AXIC
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| v23 | Signal Relays AXICOM Cradle N Relay V23154/V23162 n Multi purpose relay reliable n Great variety of contact arrangements and materials to meet specific applications n Contacts for signal loads and currents up to 5 A n DC coil, operating voltage 1.5VDC to 125VDC; AC, latching and nonlatching coils on request |
Original | ||||
| v23079 | Signal Relays AXICOM P2 Relay V23079 n Standard telecom relay (ringing and test access) line 15x7.5mm (.590x.295”) n Max. switching current 5A n 2 form C bifurcated contacts (2 changeover contacts, 2 CO) n Immersion cleanable n High sensitivity for low power consumption 140mW/ 70mW |
Original | ||||
| Signal Relays AXICOM FX2 Relay n Slim line | Signal Relays AXICOM FX2 Relay n Slim line 15x7.3mm (.590x.287”) form C bifurcated contacts (2 CO), switching current 2A n High sensitivity for low power consumption, 80mW/140mW n High dielectric characteristic, ≤1800Vrms between open contact n High surge capability (1.2/50μs and 10/700μs) meets Telcordia GR |
Original | ||||
| Non-latching type, Latching type, 1 coil not | Non-latching type, Latching type, 1 coil not energized condition rest condition RF Signal Relays AXICOM HF3 Relay n Y-Design n Frequency range DC to 3GHz n Impedance 50Ω or 75Ω n Small dimensions (14.6x7.2x10mm) n 1 form C contact (1 changeover contact) |
Original | ||||
| Signal Relays Axicom IM - D/E Relay board-space | Signal Relays Axicom IM - D/E Relay board-space 60mm2 n Slim line 10x6mm (0.39x0.24”) and n Low profile 5.65mm (0.222”) n Switching power 60W/62.5VA n Switching voltage 220VDC/250VAC n Switching current 2A n Bifurcated contacts n High mechanical shock resistance |
Original | ||||
| relay v23054 | Signal Relays Axicom Cradle S Relay V23054/V23062 n Strong magnet system and wide voltage range reliable n Contacts for signal loads and currents up to 5A n DC coils operating voltage 6VDC to 220VDC; AC, latching and nonlatching coils on request n Multi purpose relay |
Original | ||||
| Signal Relays Axicom MT2 Relay n Telecom/signal | Signal Relays Axicom MT2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 20x10mm (.795x.393”) n Switching current 2A n 2 form C contacts (2 CO, 2 changeover contacts) n Bifurcated contacts n Meets FCC Part 68 and ITU-T K20 n Slim Typical applications |
Original | ||||
| Signal Relays Axicom FX2 Relay n Slim line | Signal Relays Axicom FX2 Relay n Slim line 15x7.3mm (.590x.287”) form C bifurcated contacts (2 CO), switching current 2A n High sensitivity for low power consumption, 80mW/140mW n High dielectric characteristic, ≤1800Vrms between open contact n High surge capability (1.2/50μs and 10/700μs) meets Telcordia GR |
Original | ||||
| v23100 | Coil Data (values at 23 °C) Nominal voltage U nom Signal Relays Operate/set voltage range Minimum voltage U min Maximum voltage U max Vdc Vdc Vdc Reed Relay V23100 -V4 Release/ reset voltage Minimum Coil power Co Resista Axicom Vdc mW Ω/±1 0.75 1.80 2.25 |
Original | ||||
| Signal Relays Axicom IM - A/B Relay board-space | Signal Relays Axicom IM - A/B Relay board-space 60mm2 n Slim line 10x6mm (0.39x0.24”) and low profile 5.65mm (0.222”) n Switching power 60W/62.5VA n Switching voltage 220VDC/250VAC n Switching current 2A n Bifurcated contacts n High mechanical shock resistance up to 300g functional and 500g |
Original | ||||
| axicom fp2 | Signal Relays Axicom FP2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 14x9mm (.551x.354”) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitivity results in low nominal power consumption, 80mW for high sensitive, 140mW for sensitive version |
Original | ||||
| AXICOM Telecom-, Signal and RF Relays FX2 Relay | AXICOM Telecom-, Signal and RF Relays FX2 Relay 108-98003 • Aug. 08 Rev. F • ECOC: JM10 AXICOM 108-98003 Rev. F Telecom-, Signal and RF Relays FX2 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| AXICOM Telecom-, Signal and RF Relays FT2/FU2 | AXICOM Telecom-, Signal and RF Relays FT2/FU2 Relay 108-98004 • Sep. 08 Rev. G • ECOC: JM10 AXICOM 108-98004 Rev. G Telecom-, Signal and RF Relays FT2/FU2 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| axicom | AXICOM Telecom-, Signal and RF Relays Cradle Relay Accessories and Mounting 108-98016 • Nov. 07 • Rev. C • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98016 Rev. C Cradle Relay Accessories and Mounting Disclaimer While Tyco Electronics has made every reasonable effort |
Original | ||||
|
|
||||||
| AXICOM Telecom-, Signal and RF Relays MT2 Relay | AXICOM Telecom-, Signal and RF Relays MT2 Relay 108-98006 • No. 07 Rev. E • ECOC: JM10 AXICOM 108-98006 Rev. E Telecom-, Signal and RF Relays MT2 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| v23101 | AXICOM Telecom-, Signal and RF Relays W11 Relay V23101 108-98010 • Aug. 08 • Rev. D • ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98010 Rev. D W11 Relay V23101 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| Signal Relays AXICOM FT2/FU2 Relay n | Signal Relays AXICOM FT2/FU2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 15x7.5mm (.59x.295”) n Switching current 2A n 2 form C bifurcated contacts (2 CO) n High sensitive 24V and 48V coil versions n Meets Telcordia GR 1089, FCC Part 68 and ITU-T K20, ≥ 2500V |
Original | ||||
| v23026 | AXICOM Telecom-, Signal and RF Relays P1 V23026 Relay 108-98009 • Nov. 07 Rev. E • ECOC: JM10 AXICOM 108-98009 Rev. E Telecom-, Signal and RF Relays P1 V23026 Relay Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, |
Original | ||||
| axicom im | Signal Relays AXICOM IM Relay line 10x6mm, low profile 5.65mm and min. board-space 60mm2 n Switching current 2/5A, switching power 60W/62.5VA and switching voltage 220VDC/250VAC n Low coil power consumption, 140mW standard, 100mW for high sensitive version, 50mW for ultra |
Original | ||||
| Signal Relays AXICOM MT2 Relay n Telecom/signal | Signal Relays AXICOM MT2 Relay n Telecom/signal relay (dry circuit, test access, ringing) line 20x10mm (.795x.393”) n Switching current 2A n 2 form C contacts (2 CO, 2 changeover contacts) n Bifurcated contacts n Meets FCC Part 68 and ITU-T K20 n Slim Typical applications |
Original | ||||
| P2 V23079 Relay 108-98002 Sept 06 Rev. D ECOC: | P2 V23079 Relay 108-98002 Sept 06 Rev. D ECOC: JM10 AXICOM Telecom-, Signal and RF Relays 108-98002 Rev. D P2 V23079 Relay Index UL 508 UL 60950 IEC/EN60950 File No. E 111441 IEC Ref. Cert. No. 3271 All specifications subject to change. Consult Tyco Electronics for latest specifications. |
Original | ||||