AUTOMATIC DAISY CHAIN VME Search Results
AUTOMATIC DAISY CHAIN VME Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| TMP104YFFT | Texas Instruments | Temperature Sensor with Daisy-Chain UART Interface with up to 16 Devices 4-DSBGA -40 to 125 |
|
|
|
| TMP104YFFR | Texas Instruments | Temperature Sensor with Daisy-Chain UART Interface with up to 16 Devices 4-DSBGA -40 to 125 |
|
|
|
| BQ79600EVM-030 | Texas Instruments | SafeTI™ SPI/UART to daisy chain bridge interface with auto host wakeup evaluation module |
|
|
|
| FLHCT002 | Amphenol Communications Solutions | FLH series mini sealed connectors semi automatic crimp tool | |||
| TMP107BID | Texas Instruments | ±0.4°C Temperature Sensor with Daisy-Chain UART, EEPROM, and Alert Function 8-SOIC -55 to 125 |
|
|
Documents mentioning AUTOMATIC DAISY CHAIN VME
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| HARTING New product information HAUTI NC HARTING, | HARTING New product information HAUTI NC HARTING, Inc. har-bus® 64S, A reliable connector that offers passive switching for VME64x backplanes. HARTING presents the har-bus® 64S that offers an automatic Daisy Chain Solution for passive VME64x backplanes: |
OCR Scan | ||||
| e1302a | PDFINFO H5 5 2 6 - 0 1 20-Slot B-Size VME/VXI Mainframe HP E1302A Technical Specifications ● VME power supplies that meet VXI Specifications Power supply/fans are serviceable in rack (low MTTR) Automatic daisy chain jumpering Easy access to P2 rows A and C at rear of |
Original | ||||
| vme64x | User Manual VME / VME64x Backplanes 73972-103 Rev.001 VME / VME64x Manual Overview What is VMEbus The VMEbus started with the ANSI/VITA 1 specification in 1982. The original specification was sponsored by VITA and eventually standardized as IEEE 1014. It established a framework for 8-, 16- and 32-bit parallelbus computer architectures that can implement single and multiprocessor |
Original | ||||
| vme64x | 7U VME64x BACKPLANES FEATURES BOARD SPECIFICATIONS • Meets or exceeds ANSI/VITA 1.1-1997, VME extension • 10-layer board • 2 oz. copper power and ground standard • Exceeds ANSI/VITA 1-1994 and IEEE P1014 • PCB UL recognized 94V-0 • PCB FR-4 or equivalent |
Original | ||||
| User Manual VME / VME64x Backplanes 73972-103 | User Manual VME / VME64x Backplanes 73972-103 Rev.002 VME / VME64x Manual Overview What is VMEbus The VMEbus started with the ANSI/VITA 1 specification in 1982. The original specification was sponsored by VITA and eventually standardized as IEEE 1014. It established a framework for 8-, 16- and 32-bit parallelbus computer architectures that can implement single and multiprocessor |
Original | ||||
| augat | AUGAT/ INTCON PRDT GP S7E » ■ 1DRS33S D0D2flbfl 567 ■ AUIP Bus Grant Connector The Bus Grant connector is a version ofAugat's Switching Din connector which is specific to the VME and VXI systems. This connector Provides automatic jumpering between the bus grant |
OCR Scan | ||||
| NEWBRIDGE C R u MICROSYSTEMS m m S5E D ■ | NEWBRIDGE C R u MICROSYSTEMS m m S5E D ■ LSfifllQl Q O O O b ? a 3 ' c a s ic o 1 4 VMEbusAVICS CONTROL CIRCUIT (ACC) T -5 2 -3 3 -5 5 • Full VMEbus system controller functions • Auto-ID slot Identification • Automatic VMEbus SYSCON Identification |
OCR Scan | ||||
| ca91 | o u .m m ~ C A 9 1 C 1 4 VMEbus AVICS CONTROL CIRCUIT (ACC) The CA91C014 Advanced System Architecture Control Circuit (ACC) is part of the Advanced VMEbus Interface Chip Set (AVICS); the other part being the CA91C015 Data and Address Register File (DARF). The AVICS in |
OCR Scan | ||||
| NEWBRIDGE MICROSYSTEMS CRUMBS' 2SE D ■ tSôfllOl 0 | NEWBRIDGE MICROSYSTEMS CRUMBS' 2SE D ■ tSôfllOl 0 0 0 0 b 7 ô 3 CAS1C014 VMEbusAVICS CONTROL CIRCUIT (ÀCC) T-52 -33 -55 • Full VMEbus system controller functions • Auto-ID slot Identification • Automatic VMEbus SYSCON Identification • The CA91C014 Advanced System Architecture Control |
OCR Scan | ||||
| OEC t) 3 199' TM C R JULY 1991 CA91C014 L VMEbus | OEC t) 3 199' TM C R JULY 1991 CA91C014 L VMEbus AVICS CONTROL CIRCUIT (ACC) Full VMEbus system controller functions Auto-ID slot Identification Automatic VMEbus SYSCON Identification Bus Isolation (Bl-mode*) controller Multiple VMEbus request and release options |
OCR Scan | ||||
| Lattice ISP in Cellular Switching Stations ™ most | Lattice ISP in Cellular Switching Stations ™ most important, ISP products provide the means to complete field upgrades efficiently and cost effectively. Introduction The challenges facing cellular telephone switching station manufacturers today reflect those facing the entire |
Original | ||||
| Lattice ISP ™ in Cellular Switching Stations most | Lattice ISP ™ in Cellular Switching Stations most important, ISP products provide the means to complete field upgrades efficiently and cost effectively. Introduction The challenges facing cellular telephone switching station manufacturers today reflect those facing the entire |
Original | ||||
| augat | AUGAT/ INTCON PRDT GP S7E D ■ imS33S 0Q02B0b H3T * A U I P Bus Grant Connector Features ■ Complies with DIN 41612 ■ No special press-fit fixture required ■ Auto switching of bus grant and interrupt acknowledge lines with card removal Materials-Connector |
OCR Scan |