Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ATEX POT Search Results

    ATEX POT Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    ISO7021FD
    Texas Instruments Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 Visit Texas Instruments
    ISO7021D
    Texas Instruments Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 Visit Texas Instruments
    TPL8002-25PWR
    Texas Instruments TANDEM 64-TAP Digital Potentiometer 16-TSSOP -40 to 85 Visit Texas Instruments Buy
    TPL0401A-10QDCKRQ1
    Texas Instruments Automotive 128-Taps Single-Channel Digital Potentiometer With I2C Interface 6-SC70 -40 to 125 Visit Texas Instruments Buy
    TPL0401B-10DCKR
    Texas Instruments 128-Taps Single-Channel Digital Potentiometer With I2C Interface 6-SC70 -40 to 125 Visit Texas Instruments Buy

    Documents mentioning ATEX POT

    Document Partial File Text Tags Type PDF
    fex300
    SM/FEX300/FEX500/ATEX/IECEX-EN ProcessMaster / HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Safety instructions for electrical apparatus in potentially explosive areas, in accordance with Directive 94/9/EC (ATEX) and IEC60079-0 (IECEx) Electromagnetic Flowmeter
    Original PDF
    fex300
    SM/FEX300/FEX500/ATEX/IECEX-X1 ProcessMaster / HygienicMaster FEX300, FEX500 ATEX / IECEx Zone 1, 2, 21, 22 Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche gemäß Richtlinie 94/9/EG (ATEX) und IEC60079-0 (IECEx) Magnetisch-induktiver Durchflussmesser
    Original PDF
    atex 2033
    CNY65Exi www.vishay.com Vishay Semiconductors Optocoupler, Phototransistor Output, ATEX Certified FEATURES Top view A (±) • ATEX certificate: PTB 03 ATEX 2033 U www.vishay.com/doc?85361 C • Suitable for intrinsic safe circuits for gas • Gas safety provision: II (1) G (EX ia) IIC
    Original PDF
    V I S H AY I N T E R T E C H N O L O G Y, I N C .
    V I S H AY I N T E R T E C H N O L O G Y, I N C . OPTOCOUPLER Optocoupler - ATEX Certified for Gas and Dust CNY65Exi High-Voltage Isolation for Potentially Explosive Environments ATEX Certified The CNY65Exi provides very high voltage isolation and is ATEX certified per 94/9/EC guidelines for use in potentially
    Original PDF
    explosive
    V is h ay I ntertec h nology, I nc . Optocoupler - ATEX Certified for Gas and Dust AND TEC I INNOVAT O L OGY CNY65Exi N HN OPTOCOUPLER O 19 62-2012 High-Voltage Isolation for Potentially Explosive Environments ATEX and IEC Certified The CNY65Exi provides very high voltage isolation and is ATEX certified per 94/9/EG guidelines for use in potentially
    Original PDF
    limit switch
    Insert switch/limit switch Certification Insert switch Limit switch PTB 98 ATEX 1032 U PTB 00 ATEX 1093 X IBExU 01 ATEX 1007 X Ambient temperature -20 °C to +40 °C (-55 °C to +75 °C) -20 °C to +75 °C for dust Ex -55 °C on request Limit switch EEx d insert switch/limit switch
    Original PDF
    1mrs755862
    REF 542plus Motor Protection with ATEX − Certification User´s guide 1MRS755862 Issued: 06.12.2002 Version: C/04.12.2009 Multifunction Protection and Switchgear Control Unit REF 542plus Motor Protection with ATEX − Certification User´s guide Contents
    Original PDF
    Data Sheet SS/6553_3 ATEX Compliant Gas Analyzer
    Data Sheet SS/6553_3 ATEX Compliant Gas Analyzer for Hydrogen-cooled Alternators Type 6553 ■ CENELEC (ATEX) Certification – intrinsically safe to EExia IIC for hydrogen ■ Continuous monitoring – fail-safe alarms indicate immediate danger conditions
    Original PDF
    ms96-11ex0-r
    Signal processor MS96 for flow sensors MS96-11EX0-R/24VDC ■ ATEX category II (1) G, Ex Zone 0 ■ ATEX category II (1) D, Ex Zone 20 ■ single-channel signal processor MS96 ■ adjustment via potentiometer ■ 6 LEDs for display of the flow state ■
    Original PDF
    alternators
    Data Sheet SS/AK100 Issue 9 ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators AK100 Series „ ATEX compliant – intrinsically safe to II (1)G CENELEC EEx ia IIC T4 „ Safety – early warning of hazardous hydrogen/air mixtures „ Cost savings
    Original PDF
    awa1150-2141
    A 01/06 AWA1150-2141 Instruções de montagem Monteringsanvisning Asennusohje Montážní návod Montaažijuhend Szerelési utasítás Montāžas instrukcija Montažo instrukcija Instrukcja montażowa Montážny návod Navodila za montažo +ATEX-I2 +ATEX-I4
    Original PDF
    Absolute encoders - bus interfaces EX approval
    Absolute encoders - bus interfaces EX approval ATEX EEx d IIC T6 Optical multiturn encoders 18 bit ST / 14 bit MT X 700 - CANopen Features – Encoder multiturn / CANopen / ATEX – Optical sensing – Resolution: singleturn 18 bit, multiturn 14 bit – Clamping lange with shaft ø10 mm
    Original PDF
    Graphical Touch Terminal PMI-Range PMI v315 ATEX
    Graphical Touch Terminal PMI-Range PMI v315 ATEX Technical details Display Display type Screen diagonal Screen resolution Touchscreen Graphics operator terminal with resistive touchscreen and integrated visualisation software, approved for use in potentially explosive
    Original PDF
    o315
    Graphics Touchscreen Terminals PMI-Range PMI o315 ATEX Technical details Display Display type Screen diagonal Screen resolution Touchscreen Graphics terminal with resistive touchscreen interface approved for use in potentially explosive atmospheres, zones 2 and 22
    Original PDF