Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    ASEA THYRI Search Results

    Documents mentioning ASEA THYRI

    Document Partial File Text Tags Type PDF
    f lt k f v Catalogue RK 43-12 E ASEA Edition 1
    f lt k f v Catalogue RK 43-12 E ASEA Edition 1 Three-phase undervoltage relay type RXOTB 23 Intended among other things for con­ trol equipments and thyristor conver­ tors Operates tor symmetrical and asym­ metrical voltage drops and for phase failures
    OCR Scan PDF
    abb
    Info-No. » I P IP A IIII INFORMATION ASEA B R O W N BOVERI . ABB Relays EEC428-300 E From /D ate Reg. RFR, April 1976 Edition 1 5639 Page 1 Relay type RXETL 2 for measuring current ripple GENERAL • Detects harmful current ripple from thyristor convertors
    OCR Scan PDF
    b03-2910e
    A ill! fM M P ASEA BROWN BOVERI ABB Relays Type RXFE 4 B03-2910E Frequency relay Page 1 June 30, 1982 Data subject to change without notice Abstract Underfrequency or overfrequency relays available with wide setting ranges: underfrequency: 4 4 -5 0 Hz or 5 3 -6 0 Hz
    OCR Scan PDF
    rxkb 1
    ASEA Catalogue RK 31-14 E Edition 1 July 1975 Time-lag relay type RXKB 1 File R, Part 1 c Tô Imïb TTI lF|L|E|Xr- Resetting and recovery time approx. 20 ms. Dispersion of operating time ± 0.5 % of highest scale value. For d.c. supply. With separate rectifying
    OCR Scan PDF
    time-delay
    Àiii ASEA BROWN BOVERI ABB Relays Abstract *x Application Type RXKC 2H Dropout time-delay relay, 60 ms to 20 s B03-1611E Page 1 May 1983 Changed since June 1982 Data subject to change without notice DC voltage operated 60 ms to 20 s total range for 3 models
    OCR Scan PDF
    ASEA Catalogue RK 31-10 E Edition 2 November 1974
    ASEA Catalogue RK 31-10 E Edition 2 November 1974 Time-lag relay type RXKT 2 □ is available with tim e scales 0.2—2 s, 1—10 s, 6 -6 0 s and 0 .5 -5 min Is suitable fo r d.c. supply Requires no auxiliary voltage □ Is used in, for example, relay protections and automatic equipment for
    OCR Scan PDF
    rario
    ASEA Negative sequence current protection type RARIO for thermal overload protection of synchronous machines Bciigt H ossbo and Arne Jo h a n s e n , R elay Division Pamphlet RK 64-201 E Edition 1, January, 1972 L L D .C .. á 2 l . 3 l é .9 2 S .4 3 A S E A Pjc=j;. 7 4 5 2
    OCR Scan PDF
    ASEA jnlo-ND. RELAY DIVISION « R A T IO N ^ K 2 3
    ASEA jnlo-ND. RELAY DIVISION « R A T IO N ^ K 2 3 1 -3 0 0 pE6 RFR, Cían 19S1 Edition 2 5633 1 S tatic auxiliary relay type RXMEA 1 o Used as fast acting bounce free trip relay o O perates for a d.c. input voltage of 8 to 30 V o Operating tim e maximum 1 ms
    OCR Scan PDF
    Inie-No, AS EA RK 615-302 E Rag. Page 7433 1 Filé
    Inie-No, AS EA RK 615-302 E Rag. Page 7433 1 Filé RK 00-90 E Section 6 IHF0EMATI0H From/Dal« R3?R, Dec. 1975 Edit ioti 1 Reiay Division Distance relay type KAZOG o Static three-phase design o Switched scheme o Minimum operating time 20 m3 o Suitable for both overhead
    OCR Scan PDF
    A S E A Information Fram /tielS EER, O ct. 1975 E
    A S E A Information Fram /tielS EER, O ct. 1975 E d it io n 1 Relay Division “ ■ 000-500 E' ie g , Fags 5633 1 D e sig n o f S t a t i c B e la y a , S ta b i ll iin g A u h IH w T im * u t t f f ia ^ tro tta ^ * l ü p p l ï - f S - - ç z £ - DC niter
    OCR Scan PDF
    i * " v i. Selective earth-fault indication for
    i * " v i. Selective earth-fault indication for cables in low-voltage networks A condition for the use of this equipment is that the low-voltage network does not have a directly earthed neutral point. The equipment operates in the fol­ lowing way. When earth faults occur in the low-voltage network t a signal is obtained from
    OCR Scan PDF
    vii200-12g4
    IGBT Module Half-Bridge Configuration VII200-12G4 IC(DC) VCES VCE(sat) 3 High Short Circuit SOA Capability Symbol Test Conditions VCES VCGR T J = 25°C to 150°C T J = 25°C to 150°C; RGE = 1 MΩ VGES VGEM Continuous Transient IC25 IC100 ICM T C = 25°C
    Original PDF
    ABB Review The corporate technical journal of the
    ABB Review The corporate technical journal of the ABB Group www.abb.com/abbreview 3 / 2008 Pioneering spirits Power electronics revolution in high dc current IGBT: aA tiny chip with a huge impact page 19 measurement page 6 Team-mates: MultiMove functionality
    Original PDF
    ABB review A world in transformation 6 Power
    ABB review A world in transformation 6 Power below the waves 33 Transforming industry 45 Sustainable and available 64 Special Report Transformers The corporate technical journal Transformers are essential pieces of electrical equipment that help to transmit
    Original PDF
    electronica du/dt GT T(AV) t di/dt Günter Pilz Technische Daten von Thyristoren, Triacs und Diacs electrónica • Band 19G GÜNTER PILZ Technische Daten von Thyristoren, Triacs und Diacs MILITÄRVERLAG DER DEUTSCHEN DEMOKRATISCHEN REPUBLIK I. Auflage {(j) Militär vorlag
    OCR Scan PDF
    A M INSTRUCTIO N FronVOate R F R , March 1983
    A M INSTRUCTIO N FronVOate R F R , March 1983 Edition 2 ASEABROWNBOLERI InloHo. R K 617-300 E RegPage 7W5 1 F ile RK 00-90 E Section 6 U LT RA HIGH SPEED R E L A Y T Y PE R A LD A FO R EHV/UHV TRANSM ISSION LIN E A5ÉA S-721A3Vasfefis, SWOOOH o Unaffected by current transformer saturation and capacitor
    OCR Scan PDF
    ralza
    Imo-No. INFORMATION RF 619-001 From/Date ASS Relays Reg. RFA, No\'ember 1988 Edition 4 E Page 743.5 1 Ultra High SpeedLine Protection type RALZA Unaffected by current transformer voltage transformer transients. saturation and capacitor Ultra high Spe-edof fault detection, typical 2-5 ms.
    Original PDF
    Bulletin 3400 Digital Drive Cont Appendices
    Bulletin 3400 Digital Drive Cont Appendices Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each
    OCR Scan PDF
    Introduction to Solid State Power Electronics
    Introduction to Solid State Power Electronics Editor: John William Motto, Jr. Semiconductor Division Youngwood, Pennsylvania 15697 Acknowledgement February 1977 The material for this updated text was originally written by Dr. William E. Newell, a noted authority
    Original PDF
    Central Semiconductor Corp. Represented iSIGNTBOHICS B y: TORONTO I Regan Road, Unit 13, Bram pton, O ntario L7A 1B8 Tel: 905-846-1100 Fax:905-846-7116 E -m a il: d e s ig n tr< a id ire c t.c o m OTTAW A 21 Pine Bluff Trail, Stittsville, O ntario K2S 1E1
    OCR Scan PDF
    NEED IT NOW? BUY REMAN! SEE PAGE lxx xx xvi SOLUTIONS, SOLUTIONS… Q A r e q u a l i t y, c o s t , a n d t i m e i m p o r t a n t to you? A ELECTRICAL SOUTH! Q Do you spend too much of your valuable time dealing with too m a n y d i ff e r e n t r e p a i r v e n d o r s ?
    Original PDF