ASEA TH Search Results
Documents mentioning ASEA TH
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ASEA INFORMATION Unbalance Protection Type RYBIA | ASEA INFORMATION Unbalance Protection Type RYBIA RK 60-337 E Reg. 7456 for Series capacitors ■ DESCRIPTION 07 RELAY PROTECTION ASEA capacitor units consist of a number of parallel connected GENERAL elements each of them in series with a built-in fuse. If a short |
OCR Scan | ||||
| Al lili Mil» asea b r o w n bo veri ABB Relays | Al lili Mil» asea b r o w n bo veri ABB Relays -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
OCR Scan | ||||
| ASEA Single-phase thermal overload relay This | ASEA Single-phase thermal overload relay This relay is used to prevent detrim ental heating of 3 machine, transform er 01cable when subjected to overload. Rag. IrB de m ark Catalogue RK 65-27 E Edition 1 May 1975 File R Part 1 cIôîmTbTï F L E X ASEA Design |
OCR Scan | ||||
| i ASEA Catalogue RK 93 E Edition 1 May 1966 File | i ASEA Catalogue RK 93 E Edition 1 May 1966 File R Part 2 Frames and connectors for relays Contents: Front terminals Extension bolts and terminal screws Flush mounting frames Blanking plates Adapting frames Relay testing block RTNP P -2 3 4 9 9 10 ASEA Front terminals |
OCR Scan | ||||
| asea | A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay |
OCR Scan | ||||
| asea | ASEA C a t a lo g u e O cto b er 1966 Indicators typ e RSC and RRSC The in d ic a to rs are chiefly used in relay p ro te ctio n s to Show Whether the protec tio n o r some p a n of it has operated. M a ry ASEA relays are fitted with in d ica tin g flags |
OCR Scan | ||||
| C a t a lo g u e RK 13-5 E Indlcators type RSP | C a t a lo g u e RK 13-5 E Indlcators type RSP and RRSP T-ypn RRSP Jn p lu g -J n tfB B i-g n March 1970 E d lilo n t f7236<k ASEA ASEA Contents Qaneral Design and mode of operation Versions and mounting Maintenance Technical data and Cat. Nos. Ordering particulars |
OCR Scan | ||||
| racic | A S p Sp _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ASEA BROWN BOVERI « ,« , ________________________________________________________________________________________________________________ _ Type RACIC B03-7210 Feeder protection January 1985 Changed since May 1983 |
OCR Scan | ||||
| rarib | II m II M V II ASEA BROWN BOVERI ABBRe,ays i_____________________________________________________________________________________________________________________________________________________________ Type RARIB B03-4015E Negative phase-sequence, w „■ |
OCR Scan | ||||
| rhgx | Mil Ili» III ASEA B R O W N BO VERI A BB Relays Maximum permiss ible ambient temperature for relays Permissible power I n c e o e of n f relaying r o la w in n losses equipment in cases type RHGX and cubicles type VSG and VSH ASEA relays are designed for a maximum am |
OCR Scan | ||||
| asea | Ak 1111 ASEA BROWN BOVERI a b b Relays ------------------------------------------------------------------------------ _ Neutral point voltage selection assembly * ' _ _ ■ ---------------- B03-8510E Data subject to change without notice • New Application |
OCR Scan | ||||
| preset potentiometer | Ah Bi It ASEA B R O W N BO VERI ABB Relays ________________________________________________________________________________ _________ ___ Type RXTMB 1 _… _________________________________________________ B03-9172 .. pagei June 30. 1982 Preset potentiometer unit |
OCR Scan | ||||
| rida | RK 40-401 C om parison betw een ASEA tim e -la g o v e r- c u rr e n t re la y type RIDA w ith independent tim e -la g c h a ra c te ris tic and c o rresp o n d in g re la y s of o th er m akes CONFIDENTIAL Reg, 5621,7431 RELAY INFORMATION This c ir c u la r Is intended as a guide to ASEA s a le s re p re se n ta tiv e s |
OCR Scan | ||||
| asea | ik II11 — ________________________________________________________________________________ ASEA BROWN BOVERI ABBRe,ays Type RXBA 4 £03-8310E Fuse failure relay# Abstract Application Changed since May 1983 Data subject to change without notic • Detects single-, two- or three-phase fuse |
OCR Scan | ||||
|
|
||||||
| b03-9175e | 41 lili IP IP ASEA BROWN BOVERI --------------------- ABBRelavs :--------------------------------------------------------- Selection tables for resistors B03-9175E Page 1 January 1987 Changed since January 1985 Data subject to change without notic« These tables include MRB and MSB stud-type |
OCR Scan | ||||
| rxig 21 | ABB ASEA B R O W N BO V E RI A66 Relavs Abstract Application -------------------------------------------------------------------- — ---------------------------------------- — IT Type RXIG 21 B03-2032Ey I Instantaneous ac over- and undercurrent relays |
OCR Scan | ||||
| '• - V ASS Type TEA 1130 and TEA 1135 ABB Relays | '• - V ASS Type TEA 1130 and TEA 1135 ABB Relays Single- or two-shot, threephase reclosing relays for distribution lines ASEA BROWN BOVERI Abstract s Application • Delayed breaker reclosing after initiation from protective relay • Delay time adjustable: |
OCR Scan | ||||
| rxtla 1 | Ah I I 11 M il» abb Relays ASEA BROWN BOVERI _________________________________________________________ >____________________________________________________________________________________ Type RXTLA 1 R p r t if ip r 1 Abstract 1 1^ 1 B03-9211E u n it june3o. 1982 |
OCR Scan | ||||
| razfe | ASEA EP 613-008 Page 1 RAZFEL - COOPERATION WITH CARRIER RAZEE is designed to cooperate with %he 5 communication systems below. 1. Overreaching blocking scheme. This scheme requires a delayed trip output. The trip output is delayed by the timer TkO. TkO is |
OCR Scan | ||||
| reverse power relay | ABB ASEA BROWN BOVERI Reverse power relay for generators (RXPE 40) B03-4022E Page 1 January 1989 Data subject to change without noticc ABB Relays (830077) Abstract Application ■Single-phase reverse power relay measuring the active component of the generator current |
OCR Scan | ||||
| brown boveri | Ali ASEA BROWN BOVERI ABB Relays Abstract Application Type RAGEA 100 % generator stator ground-fault relay • Complete ground-fault protection for gen erator stators that are high impedance grounded • Monitors integrity of the neutral grounding and associated wiring |
OCR Scan | ||||
| ASEA Catalogue RK 65-13 E Edition 1 Fil« » , Part | ASEA Catalogue RK 65-13 E Edition 1 Fil« » , Part 1 ClOlMiBll iFlLlElXÍ Two or three-phase timeovercurrent protective relays Contarli* General Design Setting Diagrams Installation Ordering Reference publications Cl oj CJ For machines, transformers, cables and |
OCR Scan | ||||
| rxig 21 | A IIII | l | | l l ASEA BROWN BOVERI Instantaneous or definitetime ac overcurrent relay assemblies (RXIG 21, 22, 28) B03-2035E ^ ; 1989 Data subject to change without notice ABB Relays (830504) Abstract Application • Single-phase, two-phase or three-phase |
OCR Scan | ||||
| breaker failure relay | I Type REB 010 Breaker failure relay 1M DB05007-EN Pag© 1 September 1992 Changed since March 1992 Data subject to change without notice ASEA BROWN BOVERI, ABB Network Control & Protection T Features Application •Local redundant protection when the circuit |
OCR Scan | ||||
| Jk lili Mw» ASEA BROWN BOVERI ABB Relays Abstract | Jk lili Mw» ASEA BROWN BOVERI ABB Relays Abstract Application Type REXA 101 Single or double-shot, single or three-phase reclosing relay for transmission and subtransmission lines • Automatic high speed or delayed breaker reclosing initiated by protective relay trip |
OCR Scan | ||||