Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AMP CLS IIIG Search Results

    AMP CLS IIIG Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TA75W01FU
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, Bipolar (358) type Dual Op-Amp, 3V to 12V, SOT-505 Datasheet
    TC75S67TU
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 2.2V to 5.5V, Low Noise type:VNI=6nV/√Hz@1kHz, SOT-353F Datasheet
    TC75S102F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.5V to 5.5V, I/O Rail to Rail, IDD=0.27μA, SOT-25 Datasheet
    TC75S103F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.8V to 5.5V, I/O Rail to Rail, IDD=100μA, SOT-25 Datasheet
    TC75S51F
    Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.5V to 7.0V, IDD=60μA, SOT-25/SOT-353 Datasheet

    Documents mentioning AMP CLS IIIG

    Document Partial File Text Tags Type PDF
    Catalog 8??75 R e vise d 9 -9 9 Crimp Quality M
    Catalog 8??75 R e vise d 9 -9 9 Crimp Quality M onitor (CQM) Ordering Information for CQM To use regular min -style applicators with CQM. your Model G ’ must be equipped with machine-nnointecl sensors, called G-Adapter. CQM applicators with built-in sensors may also be used, but must be connected to the
    OCR Scan PDF
    114-25038
    Application Specification 114-25038 AMPMODU* Short Point Contacts and Housings NOTE i 26 AUG 08 Rev H All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-2019 Cluster Block
    Application Specification 114-2019 Cluster Block Housings and Contacts 05 NOV 08 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-2088 Open Barrel
    Application Specification 114-2088 Open Barrel Pigtail and Thru Splices NOTE NOTE 29 NOV 04 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification Pre- Insulated Diamond
    Application Specification Pre- Insulated Diamond Grip (PIDG*) FASTON* Receptacle Contacts NOTE i 114-- 1002 16 NOV 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification Tandem Spring and Mini-
    Application Specification Tandem Spring and Mini- Tandem Spring Housings and Contacts NOTE i 114-- 25021 01 OCT 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-- 19048 AMP- DUAC*
    Application Specification 114-- 19048 AMP- DUAC* Headers and Connectors NOTE i 18 NOV 09 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless otherwise specified, dimensions have a tolerance of +0.13 and angles have a tolerance of +2_. Figures and
    Original PDF
    Application Specification Economy Power II
    Application Specification Economy Power II Contacts and Connectors NOTE i 114-- 13265 26 OCT 09 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless otherwise specified, dimensions have a tolerance of +0.13 and angles have a tolerance of +2_. Figures and
    Original PDF
    timer connectors
    Application Specification 114-49003 Standard Timer Connectors NOTE i 27 OCT 08 Rev G All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    hd-20
    Application Specification 114-10000 HD-20 Precision Formed Contacts NOTE i 09 FEB 09 Rev T All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    MTA-100 and MTA-156 Connectors and Headers;
    MTA-100 and MTA-156 Connectors and Headers; CST-100 Connectors and Headers and SL-156 Connectors Catalog 82056 Revised 1-96 SL-.156 Crimp Contacts and Keying Plugs Contacts —I n Material and Finish .012 [0.3] bright tin plated brass or phosphor bronze; .012 [0.3] pre-tin
    OCR Scan PDF
    Application Specification 114-- 13089 Mini-
    Application Specification 114-- 13089 Mini- Universal MATE- N- LOK* Splash- Proof Sealed Connectors NOTE 15 OCT 09 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification 114-- 2161 PLASTI-
    Application Specification 114-- 2161 PLASTI- GRIP* Terminals and Splices NOTE i 03 MAY 11 Rev F All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    Application Specification PLASTI- GRIP* Terminals
    Application Specification PLASTI- GRIP* Terminals and Splices NOTE i 114-- 2161 31 JUL 09 Rev E All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
    Original PDF
    cst-100
    Data downloaded from http://www.anglia.com - the website of Anglia - tel: 01945 474747 .100 [2.54] Centerline CST-100 II Crimp Contacts and Housings Catalogue 1654741 Revised 1-04 Product Facts Application Tooling Low cost wire-to-board interconnections ■
    Original PDF
    micro mate
    Application Specification 114-- 13000 Micro MATE- N- LOK* Connectors NOTE i 10 NOV 09 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters. Unless otherwise specified, dimensions have a tolerance of +0.13 and angles have a tolerance of +2_. Figures and
    Original PDF
    amplimite
    Application Specification AMPLIMITE* HDP-22 114-10001 Connectors and High-Density 22DF Contacts NOTE 18 DEC 08 Rev G All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    Application Specification 114-2162 STRATO-THERM*
    Application Specification 114-2162 STRATO-THERM* Terminals, Splices, and Spare Wire Caps NOTE 19 NOV 08 All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and Rev C _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
    Original PDF
    MTA, CST-100 II, SL-156 and AMP Economy Power
    MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors NOT the LATEST REVISION MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors Table of Contents Introduction This catalog has been designed to assist you, our customer, identify products to satisfy your connector needs for printed circuit
    Original PDF
    cst-100
    MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors Table of Contents Introduction This catalog has been designed to assist you, our customer, identify products to satisfy your connector needs for printed circuit
    Original PDF
    cst-100
    MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors Table of Contents Introduction This catalog has been designed to assist you, our customer, identify products to satisfy your connector needs for printed circuit
    Original PDF
    cst-100
    MTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors .100 [2.54] Centerline MTA-100 IDC Connectors and Headers Product Facts ■ R ■ R Technical Documents Product Specification 108-1050 MTA-100 Connectors
    Original PDF