AMECON Search Results
AMECON Price and Stock
Infineon Technologies AG GAMECONTROLLERTOBO1GAMECONTROLLERTOBO1 |
|||||||||||
Distributors | Part | Package | Stock | Lead Time | Min Order Qty | Price | Buy | ||||
![]() |
GAMECONTROLLERTOBO1 | Box | 1 |
|
Buy Now | ||||||
![]() |
GAMECONTROLLERTOBO1 | Bulk | 3 | 1 |
|
Buy Now | |||||
![]() |
GAMECONTROLLERTOBO1 | 7 |
|
Buy Now | |||||||
![]() |
GAMECONTROLLERTOBO1 | Bulk | 1 | 1 |
|
Buy Now |
AMECON Datasheets Context Search
Catalog Datasheet | Type | Document Tags | |
---|---|---|---|
320VA
Abstract: amecon AMECON 2136
|
OCR Scan |
OD2086 2108signs EEM1999 320VA amecon AMECON 2136 | |
Contextual Info: gflM ECDN 30A CURRENT TRANSFORMER, P /N 5300-1030 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 30A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 3A, FOR 100 OHM LOAD : D.C.RESISTANCE AT 20'C : DIELECTRIC WITHSTANDING VOLTAGE HI-POT : |
OCR Scan |
L94-V0 025IN | |
Contextual Info: gf/MECDN % • O V 50A CURRENT TRANSFORMER, P / N 5300-2050 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 5 0 A , FOR 33 OHM LOAD : VOLT PER AMP RATIO AT 5A , FOR 33 OHM LOAD : D.C.RESISTANCE AT 20'C : |
OCR Scan |
025IN | |
Contextual Info: £f/MECDN 150A CURRENT TRANSFORMER, P /N 5312 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 150 A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 15 A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20‘ C DIELECTRIC WITHSTANDING VOLTAGE: |
OCR Scan |
025IN | |
Contextual Info: gfJMECON ^7lf^ THE ENERGY SAVER FOR 23 YEARS 20A CURRENT TRANSFORMER, P/N 5300-0020 ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 20A, FOR 100 OHM LOAD : VOLT PER AMP RATIO AT 2 A, FOR 100 OHM LOAD : D.C.RESISTANCE AT 2 0 'C : |
OCR Scan |
025IN | |
Contextual Info: gflM ECDN THE ENERGY SAVER FOR 23 YEARS 1OA CURRENT TRANSFORMER, P /N 5300-0010 ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 10A, FOR 200 OHM LOAD : VOLT PER AMP RATIO AT 1 A, FOR 200 OHM LOAD : D.C.RESISTANCE AT 20'C DIELECTRIC WITHSTANDING VOLTAGE HI-POT : |
OCR Scan |
L94-V0 025IN | |
Contextual Info: gflM EC D N 20A FLIP— TOP CURRENT TRANSFORMER, P /N 53FT01 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: 20 A NOM., 50 A MAX. TURNS RATIO: 3240:1 NOMINAL VOLT PER AMP RATIO AT 20 A, FOR 220 OHM LOAD 0 .0 6 7 V /A VOLT PER AMP RATIO AT 2A, FOR 220 OHM LOAD |
OCR Scan |
53FT01 | |
Contextual Info: gfjMECUN tN - 10A CURRENT TRANSFORMER, P/N 5302 THE ENERGY SAVER FOR 2 3 YEARS 0 .3 5 5 ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 1 0 A, FOR 100 OHM LO AD: VOLT PER AMP RATIO AT 1 A, FOR 100 OHM LOAD : D.C.RESISTANCE AT 20‘ C |
OCR Scan |
025IN | |
Contextual Info: 0JM ECD N ^3. O THE ENERGY SAVER ^ /nSS E 0 R 2 S YEARS WIDE DYNAMIC RANGE CURRENT TRANSFORMER QA 5300~0410 “| R / N ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 1 0 A, FOR 100 OHM LOAD : VOLT PER AMP RATIO AT 1 A. FOR 100 OHM LOAD : |
OCR Scan |
025IN | |
Contextual Info: £flMECON 200A CURRENT TRANSFORMER, P / N 53 1 3 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 20 0 A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 20 A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20'C DIELECTRIC WITHSTANDING VOLTAGE: |
OCR Scan |
025IN | |
ameconContextual Info: gflMTHEECO N ENERGY SAVER ^ 7/1 W ID E-R ANG E CURRENT TRANSFORMER, P / N 5 3 0 0 - 6 4 2 0 FOR 22 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 20 A. FOR 100 OHM L O A D : VOLT PER AMP RATIO AT 2A. FOR 100 OHM LOAD : |
OCR Scan |
025IN amecon | |
Contextual Info: gf/MECDN f C 1 THE ENERGY SAVER ' FOR 2 3 YEARS 100 A FLIP-TOP CURRENT TRANSFORMER, P /N 53FT02 ELECTRICAL SPECIFICATIONS 100 A NOM. 250 A MAX. PRIMARY CURRENT: 1000:1 NOMINAL TURNS RATIO: 0 .1 0 0 V /A VOLT PER AMP RATIO AT 1 0 0 A. FOR 100 OHM LOAD VOLT PER AMP RATIO AT 10A, FOR 100 OHM LOAD: |
OCR Scan |
53FT02 | |
5304 transformer
Abstract: RTI Electronics Amecon 5304 5304 marking code ts-130 transformer IMB Electronics amecon 5304 Electronic transformer WT diode marking 714
|
Original |
50-400Hz. 94-V0 5304 transformer RTI Electronics Amecon 5304 5304 marking code ts-130 transformer IMB Electronics amecon 5304 Electronic transformer WT diode marking 714 | |
Contextual Info: S^flMECDN 15A CURRENT TRANSFORMER, P /N 5303 THE ENERGY SAVER FOR 2 3 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 1 5 A, FOR 100 OHM LOAD : VOLT PER AMP RATIO AT 1.5A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20‘ C DIELECTRIC WITHSTANDING VOLTAGE H I-P O T : |
OCR Scan |
025IN | |
|
|||
Contextual Info: 01MECDN •“ 3. THE ENERGY SAVER r0 R 23 YEARS 7 5 A CURRENT TRANSFORMER, P /N 5310 ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 75 A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 7 .5 A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20‘ C |
OCR Scan |
01MECDN 025IN | |
Contextual Info: gfJMECDN THE ENERGY SAVER FOR 23 YEARS 5A CURRENT TRANSFORMER, P /N 5300-0005 ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 5 A, FOR 400 OHM LOAD : VOLT PER AMP RATIO AT .5 A. FOR 400 OHM LOAD : D.C.RESISTANCE AT 20‘ C : DIELECTRIC WITHSTANDING VOLTAGE HI-POT : |
OCR Scan |
L94-V0 025IN | |
Amecon 5304
Abstract: Amecon 5306
|
OCR Scan |
LM3914 Amecon 5304 Amecon 5306 | |
Contextual Info: gfiM ECON • ^ 5A CURRENT TRANSFORMER, P /N 5301 THE ENERGY SAVER FOR 23 YEARS 71^ ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 5 A, FOR 100 OHM LOAD : VOLT PER AMP RATIO AT .5 A, FOR 100 OHM LOAD : D.C.RESISTANCE AT 20‘ C : |
OCR Scan |
025IN | |
Contextual Info: gflM ECDN ^71 40A CURRENT TRANSFORMER, P/N 5307 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 40 A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 4 .0 A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20'C DIELECTRIC WITHSTANDING VOLTAGE: |
OCR Scan |
025IN | |
Amecon 5304
Abstract: 5304 transformer
|
OCR Scan |
025IN Amecon 5304 5304 transformer | |
Contextual Info: £f?MECDN 'Zynfi' 1OOA CURRENT TRANSFORMER, P /N 5311 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS 100 A NOM. 250 A MAX. 1000:1 NOMINAL 0 .1 0 0 V /A 0 .0 9 8 6 V /A 20 OHMS 4kV RMS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 100 A, FOR 100 OHM LOAD: |
OCR Scan |
025IN | |
Contextual Info: gfiM ECDN 1OOA CURRENT TRANSFORMER, P /N 5300-3011 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 100 A, FOR 15 OHM LOAD: VOLT PER AMP RATIO AT 10 A, FOR 15 OHM LOAD: D.C.RESISTANCE AT 20’ C DIELECTRIC WITHSTANDING VOLTAGE: |
OCR Scan |
025IN | |
Contextual Info: gflM ECDN ^ 50A CURRENT TRANSFORMER, P/N 5308 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS 50 A NOM. 125A MAX. 1000:1 NOMINAL 0 .1 0 0 V /A 0 .0 9 8 V /A 46 OHMS 4kV RMS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 50 A, FOR 100 OHM LOAD: |
OCR Scan |
025IN | |
Contextual Info: MflMEODN ^ /[\V 60A CURRENT TRANSFORMER, P /N 5309 THE ENERGY SAVER FOR 23 YEARS ELECTRICAL SPECIFICATIONS PRIMARY CURRENT: TURNS RATIO: VOLT PER AMP RATIO AT 60 A, FOR 100 OHM LOAD: VOLT PER AMP RATIO AT 6.0 A, FOR 100 OHM LOAD: D.C.RESISTANCE AT 20'C DIELECTRIC WITHSTANDING VOLTAGE: |
OCR Scan |
025IN |