Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AIR CONDITIONING Search Results

    AIR CONDITIONING Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DRV401AIDWP
    Texas Instruments Fluxgate Magnetic Sensor Signal Conditioning IC for Closed-Loop Applications 20-SO PowerPAD -40 to 125 Visit Texas Instruments Buy
    DRV401AIDWPRG4
    Texas Instruments Fluxgate Magnetic Sensor Signal Conditioning IC for Closed-Loop Applications 20-SO PowerPAD -40 to 125 Visit Texas Instruments Buy
    DRV401AIDWPR
    Texas Instruments Fluxgate Magnetic Sensor Signal Conditioning IC for Closed-Loop Applications 20-SO PowerPAD -40 to 125 Visit Texas Instruments Buy
    DRV401AMDWPREP
    Texas Instruments Enhanced Product, Fluxgate Magnetic Sensor Signal Conditioning IC for Closed-Loop Applications 20-SO PowerPAD -55 to 125 Visit Texas Instruments Buy
    V62/08630-01XE
    Texas Instruments Enhanced Product, Fluxgate Magnetic Sensor Signal Conditioning IC for Closed-Loop Applications 20-SO PowerPAD -55 to 125 Visit Texas Instruments Buy

    AIR CONDITIONING Datasheets Context Search

    Catalog Datasheet Type Document Tags PDF

    Siemens PT100 temperature sensor

    Abstract: Siemens PT1000 temperature sensor PT1000 temperature sensor QAM100.3 Siemens PT1000 QAM170.3.50 Siemens duct temperature sensor Resistance characteristic Pt1000 PT100 IEC 751 siemens air temperature sensors
    Contextual Info: 1 773 Duct temperature sensors QAM1. Use The sensors are used for acquiring the air temperature in heating, ventilation and air conditioning plants e.g. in supply air, extract air or mixed air ducts . They are designed for use in connection with automation equipment, display and


    Original
    pt100qam100qam160qam170+13cm1n1773enwhe101773m01siemens pt100 temperature sensorsiemens pt1000 temperature sensorpt1000 temperature sensorqam100.3siemens pt1000qam170.3.50siemens duct temperature sensorresistance characteristic pt1000pt100 iec 751siemens air temperature sensors PDF

    car impact sensor

    Abstract: solar sensor Solar sun sensor sensors used in automobiles bumper solar sensors co2 sensor circuit CO2 SENSOR SUN SENSOR solar photodiodes
    Contextual Info: Application Note Sensors for Air-conditioning in Automobiles www.epcos.com Notes Application Note Sensors for air-conditioning in automobiles Contents Sensors for air-conditioning in


    Original
    car impact sensorsolar sensorsolar sun sensorsensors used in automobiles+6bumpersolar sensorsco2 sensor circuitco2 sensorsun sensorsolar photodiodes PDF

    delphi sensor

    Abstract: weight sensor design evaporator color sensor signal conditioning
    Contextual Info: SENSORS Delphi Evaporator Air Temperature Sensor Description The Delphi Evaporator Air Temperature EVAP Sensor is a continuous function device that changes resistance inversely to temperature. It measures the air temperature at the heating, ventilation and air conditioning (HVAC) evaporator


    Original
    delphi sensorweight sensor designevaporatorcolor sensor signal conditioning PDF

    QBM81-3

    Abstract: QBM81-10 Siemens QBM81 QBM81-5 CA1N1589E Differential Pressure siemens 604.15011 siemens QBM81-3 pg11 cable gland IEC529
    Contextual Info: 1 Differential Pressure Detector 552 QBM81-. for monitoring of air pressure Differential pressure detector for ventilation and air conditioning systems • For monitoring of air filters, air flow, fan belts • For monitoring of pressure in clean rooms, kitchens etc.


    Original
    qbm81-ca1n1552eqbm81-3qbm81-10+8siemens qbm81qbm81-5ca1n1589edifferential pressure siemens604.15011siemens qbm81-3pg11 cable glandiec529 PDF

    MVSS302

    Abstract: ASHRAE fpm 250 airflow 3M Purification MVSS-302 air handling unit automotive air filter D5132-04
    Contextual Info: 3M High Air Flow HAF Air Filters The open channel construction of 3M High Air Flow (HAF) Air Filters offers low initial airflow resistance while its unique microstructure and electrostatic charge provide effective particle capture and retention. This may translate to fewer filter changeouts, reduced coil cleaning, and/or reduced maintenance


    Original
    mvss302ashraefpm 250 airflow3m purification+4mvss-302air handling unitautomotive air filterd5132-04 PDF

    Contextual Info: Data Sheet TMA5 Mini-vane Anemometer The TMA5 is a compact, pocket size tool for indoor air quality and HVAC / R technicians measuring Heat / Ventilation / Air conditioning / Refrigeration wind flow and temperature in residential, commercial and industrial air conditioning systems.


    Original
    cr2032877-amprobe PDF

    Contextual Info: Data Sheet TMA5 Mini-vane Anemometer The TMA5 is a compact, pocket size tool for indoor air quality and HVAC / R technicians measuring Heat / Ventilation / Air conditioning / Refrigeration wind flow and temperature in residential, commercial and industrial air conditioning systems.


    Original
    cr2032877-amprobe PDF

    schematic diagram induction heating

    Abstract: induction furnace circuit diagram igbt based induction furnace circuit diagram induction furnace schematic induction furnace 2x8 segment display IGBT PIC MICROCONTROLLER single phase induction motor speed control schematic diagram "induction heating" of induction heating furnace using IGBT schematic diagram induction furnace
    Contextual Info: AN861 Smart Air Handler using ProMPT and the PIC18F2539 Author: Jon Burroughs Microchip Technology Inc. INTRODUCTION In many heating, ventilation, and air conditioning HVAC applications, air handler motors are either off, or on at full speed. However, by adding variable speed


    Original
    an861pic18f2539d-85737ds00861a-page+10schematic diagram induction heatinginduction furnace circuit diagramigbt based induction furnace circuit diagraminduction furnace schematicinduction furnace2x8 segment displayigbt pic microcontroller single phase induction motor speed controlschematic diagram "induction heatingof induction heating furnace using igbtschematic diagram induction furnace PDF

    NM24A-SR

    Contextual Info: Technical data sheet Damper actuator NM24A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 2 m2 • Torque 10 Nm • Nominal voltage AC/DC 24 V


    Original
    nm24anm24a-snm24ap5nm230a+3nm230a-snm24a-srnm230a-sr PDF

    SM230A

    Abstract: SM24A-S SM24A-V SM24A-SR T2-SM230A
    Contextual Info: Technical data sheet Damper actuator SM230A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC 100 . 240 V


    Original
    sm230asm24asm24a-ssm24ap5+7sm24a-srsm24a-mfsm230asrsm24a-mpsm24a-vsm230a-st2-sm230a PDF

    NM24AP5

    Abstract: NM24A-S
    Contextual Info: Technical data sheet Damper actuator NM230A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 2 m2 • Torque 10 Nm • Nominal voltage AC 100 . 240 V


    Original
    nm230anm24anm24a-snm24ap5+3nm230a-snm24a-srnm230a-sr PDF

    SM24A-SR

    Abstract: T2-SM24A-SR SM230A SM24A-V
    Contextual Info: Technical data sheet Damper actuator SM24A-SR Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC/DC 24 V


    Original
    sm24a-srsm24asm24a-ssm24ap5+7sm24a-mfsm230asrsm24a-mpsm24a-vsm230a-st2-sm24a-srsm230a PDF

    EN 60730-1

    Contextual Info: Technical data sheet GM24A-SR Modulating damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 8 m2 • Torque 40 Nm • Nominal voltage AC/DC 24 V


    Original
    gm24a-srgm24agm230agm24a-mf+5gm24a-mpgm24a-vsm24a-vgm230a-ven 60730-1 PDF

    LM24A-S

    Abstract: EN 60730-1 LM24A LM24AP5
    Contextual Info: Technical data sheet Damper actuator LM24A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC/DC 24 V


    Original
    lm24alm24a-slm24ap5lm230a+4lm230a-slm24a-srlm230a-sren 60730-1 PDF

    LM24A-SR

    Abstract: LM24A-S T2-LM24A-SR ZAD24
    Contextual Info: Technical data sheet Damper actuator LM24A-SR Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC/DC 24 V


    Original
    lm24a-srlm24alm24a-slm24ap5+5lm230alm230a-slm230a-srt2-lm24a-srzad24 PDF

    Heating, Ventilation and Air Conditioning

    Contextual Info: 565C1 Hotwire Air Velocity Meter APPLICATIONS • Air flow measurements in heating, ventilation and air conditioning systems • Where low and high feet per minute readings are critical - you must use a hot wire below 80 feet per minute. Comes hardwired with protective boot A604


    Original
    rs-232565c5-0905heating, ventilation and air conditioning PDF

    LM230A

    Contextual Info: Technical data sheet Damper actuator LM230A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC 100 . 240 V


    Original
    lm230alm24alm24a-slm24ap5+3lm230a-slm24a-srlm230a-sr PDF

    LM24A-S

    Abstract: LM24A s3 via s3 application sheet LM24AP5
    Contextual Info: Technical data sheet Damper actuator LM24A-S Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC/DC 24 V


    Original
    lm24a-slm24alm24ap5lm230a+5lm230a-slm24a-srlm230a-srs3 vias3 application sheet PDF

    LM230A-S

    Abstract: LM230 s3 application sheet
    Contextual Info: Technical data sheet Damper actuator LM230A-S Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 1 m2 • Torque 5 Nm • Nominal voltage AC 100 . 240 V


    Original
    lm230a-slm24alm24a-slm24ap5+5lm230alm24a-srlm230a-srlm230s3 application sheet PDF

    Q62705K352

    Abstract: 4267G "injector driver" PRESSURE SENSOR IC EGR Valve Position Sensor capacitive pressure sensor 6230-GP injector diesel C167 C505
    Contextual Info: P R O D U C T B R I E F Integrated Pressure Sensor IC for Barometric Air Pressure Measurement Application Features The manifold air pressure MAP and barometric air pressure (BAP) are important parameters to compute the air-fuel ratio provided to the engine


    Original
    b112-h7866-x-x-7600q62705k3524267ginjector driver+7pressure sensor icegr valve position sensorcapacitive pressure sensor6230-gpinjector dieselc167c505 PDF

    diesel engine

    Abstract: Common rail injector driver 4267G diesel injector manufacturer K352 infineon capacitive pressure sensor an tle 4990 injector diesel Common rail injector Technical data diesel injector
    Contextual Info: P R O D U C T B R I E F Integrated Pressure Sensor IC for Barometric Air Pressure Measurement Application Features The manifold air pressure MAP and barometric air pressure (BAP) are important parameters to compute the air-fuel ratio provided to the engine


    Original
    b112-h7866-x-x-7600diesel enginecommon rail injector driver4267g+7diesel injector manufacturerk352infineon capacitive pressure sensoran tle 4990injector dieselcommon rail injector technical datadiesel injector PDF

    SF24A

    Abstract: NF230 NF24A-S2 NF230A 45dBA
    Contextual Info: Technical data sheet SF24A Spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings • For air dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC/DC 24 V • Control: Open-close


    Original
    sf24anf24anf230asf230a+6nf24a-s2sf24a-s2nf230a-s2sf230a-s2nf23045dba PDF

    EN 60730-1

    Abstract: air flow damper GM24A GM24AM
    Contextual Info: Technical data sheet GM24A Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations • For air control dampers up to approx. 8 m2 • Torque 40 Nm • Nominal voltage AC/DC 24 V • Control: Open-close


    Original
    gm24agm230agm24a-srgm24a-mf+7gm24a-mpgm24a-vsm24a-vgm230a-ven 60730-1air flow dampergm24am PDF

    SF24A-S2

    Abstract: SF24A SF24A-S
    Contextual Info: Technical data sheet SF24A-S2 Spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings • For air dampers up to approx. 4 m2 • Torque 20 Nm • Nominal voltage AC/DC 24 V • Control: Open-close


    Original
    sf24a-s2nf24asf24anf230a+5sf230anf24a-s2nf230a-s2sf230a-s2sf24a-s PDF