Part Number
    Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    AC RELAYS Search Results

    AC RELAYS Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    DS3680D
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy
    ULN2003LVPWR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-TSSOP -40 to 85 Visit Texas Instruments Buy
    ULN2003V12PWR
    Texas Instruments Low Power 7 channel Relay Driver 16-TSSOP -40 to 125 Visit Texas Instruments Buy
    ULN2003LVDR
    Texas Instruments Low Power 3.3V & 5V Relay Driver 16-SOIC -40 to 85 Visit Texas Instruments Buy
    DS3680DE4
    Texas Instruments Quad Telephone Relay Drivers 14-SOIC 0 to 70 Visit Texas Instruments Buy

    Documents mentioning AC RELAYS

    Document Partial File Text Tags Type PDF
    AC Input Unit G32A-B AC Input Unit Enabling AC
    AC Input Unit G32A-B AC Input Unit Enabling AC Operation • Connects to a maximum of two G3PA-VD Relays. Ordering Information Name AC Input Unit Rated input voltage 100/120 VAC Model G32A-B 200/240 VAC Application Example ■ AC Operation Two G3PA-VD Relays and One G32A-B AC Input Unit
    Original PDF
    g32a-b
    AC Input Unit G32A-B AC Input Unit Enabling AC Operation Connects to a maximum of two G3PA-VD Relays. RC Ordering Information Name Rated input voltage AC C Input u Unit U Model G32A-B G3 100/120 VAC 200/240 VAC Application Examples Note: AC Operation Two G3PA-VD Relays and One G32A-B AC Input Unit
    Original PDF
    emergency stop relay
    Emergency Stop Relays, Safety Gate Monitors Category 2, EN 954-1 PNOZ X7 24 V DC/AC, PNOZ X7 AC Technical Data PNOZ X7 24 V DC/AC PNOZ X7 AC Electrical Data Supply Voltage 24 V DC/AC Tolerance Power Consumption Voltage and Current at reset circuit/ feedback control loop
    Original PDF
    emergency stop relay
    Emergency Stop Relays, Safety Gate Monitors Category 2, EN 954-1 PNOZ X7 24 V DC/AC, PNOZ X7 AC Farnell Codes ; 4439314-9326-9338 Technical Data PNOZ X7 24 V DC/AC PNOZ X7 AC Electrical Data Supply Voltage 24 V DC/AC Tolerance Power Consumption Voltage and Current at reset circuit/
    Original PDF
    g3fd
    Solid-state Relay G3F/G3FD Plug-in Type Power Relays (Same as the MY Series) Sizes and terminal arrangements are the same as OMRON MY-series Power Relays. The same Sockets are also used. DC-AC, DC-DC, AC-AC, AC-DC Types. Operating indicator provided. Ordering Information
    Original PDF
    ac motors
    Contactors & Control Relays Safety Contactors 104S-C Product Selection Reversing AC-Operated Contactors • AC Operating Mechanism, 3 Main Contacts • Includes Mechanical/Electrical Interlock • Includes Reversing Power Wiring Ratings for Switching AC Motors
    Original PDF
    sta07220
    S/MOD/STA07220/DC/14/05/2002 page 1 / 2 F/GB Relais Statique AC AC Solid State Relay STA07220 24V AC/DC input 230V/2A AC output • Compatibilité du brochage avec les Relais Electro-mécaniques . • Commande AC et DC Non polarisée. • Sortie AC synchrone.
    Original PDF
    spa07420
    S/MOD/SPA07420/C/06/01/2000 page 1 / 2 F/GB Relais Statique AC AC Solid State Relay SPA07420 24V AC/DC input 230V/4A AC output • Compatibilité du brochage avec les Relais Electro-mécaniques . • Commande AC et DC Non polarisée. • Sortie AC synchrone.
    Original PDF
    spa07420
    S/MOD/SPA07420/D/14/05/2002 page 1 / 2 F/GB Relais Statique AC AC Solid State Relay SPA07420 24V AC/DC input 230V/4A AC output • Compatibilité du brochage avec les Relais Electro-mécaniques . • Commande AC et DC Non polarisée. • Sortie AC synchrone.
    Original PDF
    dua01
    Monitoring Relays 1-Phase AC/DC Over Voltage - AC Over Current Types DUA01, PUA01 DUA01 • AC/DC over voltage monitoring relay • Selection of measuring range by DIP-switches • Measuring ranges: 2 to 20 VAC/DC, 5 to 50 VAC/DC, 20 to 200 VAC/DC, 50 to 500 VAC/DC, 0.4 to 4 Vp AC
    Original PDF
    dua01
    Monitoring Relays 1-Phase AC/DC Over Voltage - AC Over Current Types DUA01, PUA01 DUA01 • AC/DC over voltage monitoring relay • Selection of measuring range by DIP-switches • Measuring ranges: 2 to 20 VAC/DC, 5 to 50 VAC/DC, 20 to 200 VAC/DC, 50 to 500 VAC/DC, 0.4 to 4 Vp AC
    Original PDF
    dua01
    Monitoring Relays 1-Phase AC/DC Over Voltage - AC Over Current Types DUA01, PUA01 DUA01 • AC/DC over voltage monitoring relay • Selection of measuring range by DIP-switches • Measuring ranges: 2 to 20 VAC/DC, 5 to 50 VAC/DC, 20 to 200 VAC/DC, 50 to 500 VAC/DC, 0.4 to 4 Vp AC
    Original PDF
    dua01
    Monitoring Relays 1-Phase AC/DC Over Voltage - AC Over Current Types DUA01, PUA01 DUA01 • AC/DC over voltage monitoring relay • Selection of measuring range by DIP-switches • Measuring ranges: 2 to 20 VAC/DC, 5 to 50 VAC/DC, 20 to 200 VAC/DC, 50 to 500 VAC/DC, 0.4 to 4 Vp AC
    Original PDF
    jds9
    SOLID STATE RELAYS AC SOLID STATE RELAYS JDS9 1Y PS12 1Y 2 AMP 10 AMP 25 AMP QUALIFIED TO MIL–R–28750/9 MEETS DESC DWG. 86031/2 MIL–R–28750/10 (QPL PENDING) ■ _ + 8 + + DC INPUT _ 1 1 1 2 3 4 6 AC POWER TERMINAL VIEW 4 LOAD AC POWER AC POWER ■
    Original PDF
    c
    CPM2A Specifications CPM2A General Specifications Item Supply pp y voltage g Operating p g voltage g range Power consumption p Inrush current External power supply (AC power supplies only) AC power DC power AC power DC power AC power DC power AC power DC power
    Original PDF
    DY (ADY1, 3) 10A MINIATURE POWER RELAY FOR
    DY (ADY1, 3) 10A MINIATURE POWER RELAY FOR INDUCTIVE LOADS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ DY RELAYS (ADY) FEATURES TYPICAL APPLICATIONS 1. Compact size: 1 Form A (10A 250V AC), 1 Form A 1 Form B (8A 250V AC)
    Original PDF
    DY (ADY1, 3) 10A MINIATURE POWER RELAY FOR
    DY (ADY1, 3) 10A MINIATURE POWER RELAY FOR INDUCTIVE LOADS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ DY RELAYS (ADY) FEATURES TYPICAL APPLICATIONS 1. Compact size: 1 Form A (10A 250V AC), 1 Form A 1 Form B (8A 250V AC)
    Original PDF
    AC Power Source/Analyzers… an integrated AC power
    AC Power Source/Analyzers… an integrated AC power solution Agilent AC Power Source/ Analyzers provide a complete AC test solution. As AC sources, they combine the capabilities of a power amplifier and an arbitrary waveform generator. This allows you to simulate normal waveforms and many types
    Original PDF
    Relays - MCZ-TRAK-SERIES Ordering data Input
    Relays - MCZ-TRAK-SERIES Ordering data Input Rated voltage Rated current AC Rated current DC Power rating AC Response/dropout Volt DC Response/dropout Volt AC pickup/dropout current DC pickup/dropout current Digital signalling MCZ R TRAK 1 CO contact or 1 NO contact
    Original PDF
    Monitoring Relays 1-Phase AC/DC Over Current
    Monitoring Relays 1-Phase AC/DC Over Current Types DIA01, PIA01 • AC/DC over current monitoring relay Current measured through internal shunt Measuring range 0.5 to 5 A AC/DC Adjustable current limit on relative scale Adjustable hysteresis
    Original PDF