ABB SLCE 16 Search Results
Documents mentioning ABB SLCE 16
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| radss | A ll» nvn Auxiliary current transformers for differential relay RADSS 3-phase SLCE 12 Features SLCE12, SLCE16 and SLX E 4 SLCE 16 • High secondary knee-point voltage • Iron core with a small anti-remanence air-gap • Highly inductive magnetizing impedance |
OCR Scan | ||||
| radsb | Type RADSB A8EA 8R O W N BOVEFtf Transformer differential protection 1MDB04007-EN Page 1 March 1992 Changed since August 1990 Data subject to change wihtout notice ABB N etw ork Control & Protection (840536) I (90142) Features Application •Complete phase and earth fault protection |
OCR Scan | ||||
| ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three | ABB ASEA BROWN BOVERI ABB Relays Type RACIF Three phase overcurrent and ground-fault relay independent of auxiliary power supply B03-2314E Page 1 January 1989 Changed since January 1987 Data subject to change without notic (860567; Abstract Overcurrent and ground-fault protection |
OCR Scan | ||||
| radss | Auxiliary current transformers SLCE 12, SLCE 16 for differential relay RADSS and SLXE 4 1MRK 513 011-BEN 1-phase and 3-phase SE980091 Page 1 Issued March 1999 Changed since December 1998 Replaces 1MRK 513 009-BEN and 1MRK 513 010-BEN Data subject to change without notice |
Original | ||||
| radss | Ä, AS'i Type RADSS K i v .. 8 fiW ,‘-f %gä? 1MDB05003-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice Busbar protection ABB Network Control & Protection (810258) I (810260) Features Application (880568) • Percentage restraint bus differential relay |
OCR Scan | ||||
| Type RACIF ASEA BROWN BGVERI 1MDB07007-EN Phase | Type RACIF ASEA BROWN BGVERI 1MDB07007-EN Phase and neutral overcurrent protection independent of auxiliary supply Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB N etw ork Control & Protection (SE 90632) Features Application |
OCR Scan | ||||
| Phase and neutral overcurrent protection | Phase and neutral overcurrent protection independent of auxiliary supply RACIF 1MRK 507 003-BEN Page 1 Issued February 1997 Changed since November 1995 Data subject to change without notice (SE 970167) Features • Overcurrent and earth fault protection • No auxiliary power supply required |
Original | ||||
| Bus differential relay using auxiliary summation | Bus differential relay using auxiliary summation CT’s REB 101 1-phase 1MRK 505 006-BEN Page 1 Issued: September 2006 Revision: C Data subject to change without notice (SE970178) Features • Percentage restrained differential relay for phase-to-phase and phase-to-earth faults |
Original | ||||
| Bus differential relay REB 103 3-phase 1MRK 505 | Bus differential relay REB 103 3-phase 1MRK 505 007-BEN (SE970146) Page 1 Issued: September 2006 Revision: C Data subject to change without notice Features • Percentage restrained differential relay for phase-to-phase and phase-to-earth faults. • Very high E/F-sensitivity of the differential |
Original | ||||
| radss | I n io - f io . A l i n INFORMATION f >IP IP F «m v D a l& *saBi™»wai add ABB Relays RFR, December 19S3 Edition 2 RK 637-302 E Reg- Page 7^51 Supersedes Ed?tion { 1 Auxiliary CT’s for RADS5 bus protection The RADSS bus differential protection uses auxiliary CT’s for |
OCR Scan | ||||
| 016-ben | Multi-purpose percentage restraint differential protection RADSC 1MRK 509 016-BEN Page 1 Issued June 2002 Changed since June 1999 Data subject to change without notice (SE970169) Features • Complete phase and earth fault protection for generators, motors, reactors, cables or |
Original | ||||
| radss | n i l IB I I Type RADSS jp ^ |p |p uitrahigh-speed bus ASEA B R O W N B O VER I c iif f S T G n tid l B03-6010E f g |^ y Data subject to change without notice ABB Relays o o (810258) Abstract Application ) • Protection for buses or short lines |
OCR Scan | ||||
| radsb | Transformer differential protection RADSB 1MRK 504 002-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970883) Features • Three phase differential protection with two, three, five or six through-current restraint inputs |
Original | ||||
| radhl | Pilot-wire differential relay for lines with two or more terminals RADHL 1MRK 507 004-BEN Page 1 Issued: March 2003 Revision: A Data subject to change without notice Pilot-wire differential relay RADHL with RXHL 401 Features • Phase and earth fault protection for cable |
Original | ||||
|
|
||||||
| REB 103 and REB 101 1wirk 505 002-BEN Busbar | REB 103 and REB 101 1wirk 505 002-BEN Busbar protection Page 1 November 1995 Changed since March 1992 Replaces 1MDB05006-EN Data subject to change without notice ABB Network Partner (SE 90 00 20) Features • Based upon a previous design with long experience |
OCR Scan | ||||
| radss | Busbar protection with auxiliary summation CT’s RADSS 1-phase 1MRK 505 009-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE980086) Features • Percentage restrained bus differential relay for phase and earth faults |
Original | ||||
| b03-401 | ih a i i l * * ip ip ASEA B R O W N BO VERI ABB Relays Abstract Application Design Type RADSG Ultrahigh-speed generator differential relay B03-4011E P age 1 J une 30, 1982 D a ta subject to c h a n g e without notice • 1—3 ms fault detection 5 —10 ms to trip |
OCR Scan | ||||
| radss | Busbar differential protection RADSS 3-phase 1MRK 505 008-BEN Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE 81 02 58) (SE 81 02 60) Features • Percentage restrained bus differential relay for phase and earth faults |
Original | ||||
| radss | RADSS 1MRK 505 003-BEN Busbar protection Changed since March 1992 Replaces 1M D B 0 5 00 3-E N D ata subject to change without notice ABB Network Partner (SE 81 02 58) (SE 81 02 60) Features Application (SE 88 05 68) • Percentage restraint bus differential relay |
OCR Scan | ||||
| *HQHUDO GLIIHUHQWLDO SURWHFWLRQ 5(' 1MRK | *HQHUDO GLIIHUHQWLDO SURWHFWLRQ 5(' 1MRK 505 031-BEN Page 1 Revision B Issued: November 2003 Data subject to change without notice Three-Phase Terminal )HDWXUHV Three One-Phase Terminals • High speed general differential protection. Minimal operating time around 10 ms |
Original | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| radhl | ABB # * ü l» 1nfO‘Wü. ILK612-301 INFORMATION FiontfDitB Reg. E P4£6 ASEft B R O W N BOVÊRI RFR, January 1978 Edition 1 Relay Division 7434 1 Pile RK 00-90 E Section 6 Pilot-vire differential relay type RADHL for cables and overhead lines ___________________________________ |
OCR Scan | ||||
| differential relay | A Et It m ir ASE*BROW NBOVERI , f \ Catalogue RK 61-10 E Edition 1 October 197S ABB Relays /,______________________________________________________________ Pilot-wire differential relay type RADHL Icïô ImïbmTî TfTl I w for cables and overhead lines • |
OCR Scan | ||||
| reb 670 | Busbar differential protection IED REB 670 Buyer's Guide Pre-configured 1MRK 505 172-BEN Revision: A Issued: February 2007 Data subject to change without notice Page 1 Features • IED for differential protection of busbars, meshed corners and T-protection |
Original | ||||