ABB S270 Search Results
ABB S270 Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| ND9BS2700 | Amphenol Communications Solutions | ix Industrial, Input output connectors, Receptacle, Type B Vertical, SMT, Palladium-Nickel Gold | |||
| ND9AS2700 | Amphenol Communications Solutions | ix Industrial, Input output connectors, Receptacle, Type A Vertical, SMT, Palladium-Nickel Gold | |||
| TPS27082LDDCR | Texas Instruments | PFET Load Switch with Adjustable Slew Rate, Fast Transient Isolation & Hysteretic Control 6-SOT-23-THIN -40 to 125 |
|
|
|
| TPS27081ADDCR | Texas Instruments | 1.2V - 8V, 3A PFET high side load switch w/ level shift & adj slew rate control 6-SOT-23-THIN -40 to 85 |
|
|
|
| TVS2701DRBR | Texas Instruments | 27-V bidirectional flat-clamp surge protection device 8-SON -40 to 125 |
|
|
Documents mentioning ABB S270
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| s270 | Line Protection Devices MCB- S270 & S260 series Conforms to IEC60898, IS8828-10kA and IEC60947-2 ABB- the pioneer in MCB technology brings to you the S270 range based on system pro M, a modular system developed by ABB. The S270 range of MCBs are designed and constructed to |
Original | ||||
| 2 | In consideration of modifications to Standards and materials, the characteristics and overall dimensions indicated in this catalogue may be considered binding only following confirmation by ABB Copyright 2010 ABB. All right reserved. System pro M compact® and other modular devices for low voltage installation |
Original | ||||
| s800 | Technical catalogue S800 The High Performance MCB ABB ABB Table of Contents A question of power. Definitively more power. The extensive S800 range offers the right High gured and operated safely in an uncomplica- Performance MCB with high-rated breaking ted manner. Convincing selectivity ratings to |
Original | ||||
| Pro M Miniature circuit breakers General | Pro M Miniature circuit breakers General information General information CSA C22.2 Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for use by Underwriters Laboratories Standard |
Original | ||||
| stotz | Technical data System pro M System pro M Residual Current-operated Circuit Breakers F 660 SK 5 ABB STOTZ-KONTAKT 1 System pro M Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be |
Original | ||||
| s260 | 14 em st M y S ro P Accessories S260, S270 & S280 Electrical accessories Catalog number List price Delivery class Suggested order quantities Wgt. oz. (1 pc.) Undervoltage release For field mounting, left or right side 12 VDC 24 VAC/VDC 48 VAC/VDC 110 VAC/VDC |
Original | ||||
| Line Protection Contents Miniature Circuit | Line Protection Contents Miniature Circuit Breakers (MCB’s)… 3-2 Protecta Type B Pan Assemblies… 3-12 High Performance MCB’s… |
Original | ||||
| Technical catalogue System pro M compact® and | Technical catalogue System pro M compact® and other modular devices for low voltage installation System pro M compact® and other modular devices for low voltage installation In consideration of modifications to Standards and materials, the characteristics |
Original | ||||
| rccb | Technical data System pro M Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range System pro M 1 System pro M When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease. |
Original | ||||
| Technical Data System pro M Industrial Miniature | Technical Data System pro M Industrial Miniature Circuit-Breakers S 220 series System pro M 1 System pro M When connecting aluminum conductors, ensure that the contact surfaces of the conductors are cleaned, brushed and greased. For finely stranded conductors, |
Original | ||||
| Technical data Miniature circuit-breakers S 280 | Technical data Miniature circuit-breakers S 280 UC series System pro M Prior to connection of aluminum conductors (ͧ 4 mm2) ensure that their contact points are cleaned, brushed and coated with grease. Conditions for Delivery and Sale For domestic business, the Standard Terms for Delivery of Products and Services of the Electrical |
Original | ||||
| System pro M Selection Table Modular Installation | System pro M Selection Table Modular Installation Equipment with UL/CSA-Approvals 1 System pro M When connecting aluminium conductors, ensure that the contact surfaces of the conductors are cleaned, brushed and treated with grease. Re-tighten contacts terminals after 6 to 8 weeks' time |
Original | ||||
Technical Data System pro M System pro M compact® Miniature Circuit-Breakers for Railway Applications Railway application prEN 45545-1 Level HL4 220/440 V DC 230/400 V AC 60 V DC 230/400 V AC 1. Fire Resistance Miniature circuit-breakers of the S 200 P and S 280 UC series, |
Original | |||||
| System pro M compact ȭ Technical data System | System pro M compact ȭ Technical data System Navigate pro MDocument compact ® Miniature circuit-breakers S 200/S 200 M Residual-current-operated circuit-breakers F 200 Cross wiring/accessories 1 System pro M compact ® Miniature circuit-breaker S 201 Standard Terms for Delivery and Sale |
Original | ||||
|
|
||||||
| semicon indexes | I SEMICON INDEXES Contents and Introduction Manufacturers' Information V O LU M E 3 INTERNATIONAL INTEGRATED CIRCUITS INDEX 15th EDITION 1997 Numerical Listing of Integrated Circuits Substitution Guide U D C 621.382.3 Diagram s THE S E M IC O N INTERNATIONAL INDEXES |
OCR Scan | ||||
| The E ngineering Staff of TEXAS INSTRUMENTS | The E ngineering Staff of TEXAS INSTRUMENTS INCORPORATED Semiconductor Memory Data Book y for \ T exas In Design Engineers s t r u m e n t s >le of Contents • Alphanumeric Index • GENERAL INFORMATION Selection Guides • Glossary INTERCHANGEABILITY GUIDE |
OCR Scan | ||||