ABB RXMH Search Results
Documents mentioning ABB RXMH
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| brown boveri | ABB ASEA BROWN BOVERI ABB Relays High-speed tripping assembly Application The high-speed tripping assembly is used for several protective relays which do not have trip relays. The unit can trip a maximum of five breakers. Design The tripping assembly consists of a high-speed |
OCR Scan | ||||
| b03-1003e | J% |P IP IP SB s ASEA BRO W N B O VERl ABB Relays Auxiliary relay datatable data V4W41V* bo3- ioo3 e Kryi«» Changed since January 1987 Data subject to change without notic ABB Relays Auxiliary relay data table B03-1003E Page 2 Light-duty single contacts |
OCR Scan | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| 2610e | F lI P I»I19 ASEA BROWN BOVERI ABB Relays Abstract B03-2610E Positive phase-sequence time-undervoltage relay assembly (RXODB 4) • Measures positive-phase-sequence vol tage • Inverse-time characteristic with definiteminimum time • Operate value continuously adjustable 0.4 |
OCR Scan | ||||
| Type RAAAE B03-8010C Page 1 Single-shot, | Type RAAAE B03-8010C Page 1 Single-shot, three-phase reclosing relây ABB Relays 1983 Data subject to change without notice for transmission and distribution lines (840515) Abstract Application • Delayed breaker reclosing after initiation from protective relay |
OCR Scan | ||||
| shunt reactor | Selection Guides Shunt reactor protection 1MRK501 013-BEN Page 1 November 1995 Changed since March 1992 Replaces 1MDB01002-EN Data subject to change without notice ABB Network Partner Shunt reactor protection *s Application notes The types of reactors considered are the com |
OCR Scan | ||||
| ik mm n ra ASEA BROWN BOVERI ABB Relays Type | ik mm n ra ASEA BROWN BOVERI ABB Relays Type RAAAF Double-shot reclosing relay for transmission and distribution lines Abstract Application • Delayed breaker reclosing after initiation from protective relay • Available in two versions: Version -DC for use with distance relays |
OCR Scan | ||||
| rxmh | 41 I I I I Type RXMH 2 s iH P J S Heavy-duty auxiliary relay, ASEA BR O W N BOVERI g Q Q ^ Q Q ^ g B03-1112E Data subject to. change without not ABB Relays Abstract • AC or DC voltage operated • no or nc contacts • Maximum power consumption: dc 4.6 W |
OCR Scan | ||||
| rxeg | Type RXEG ASEA B! .FiOVER Voltage relay and protection assemblies 1MDB09009-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection (830506) Features Application • Single- and three-phase versions for o veror undervoltage protection |
OCR Scan | ||||
| voltage relay | AM ASEA BROWN BOVERI Instantaneous or definitetime ac over- or undervoltage relay v v /i l a i j c ■ C la y assemblies (RXEG 21) B03-2535E January 1987 Changed since Data subject to change without notice -hangàdMay1983 ABB Relays (830506) Abstract Application |
OCR Scan | ||||
| radss | Ä, AS'i Type RADSS K i v .. 8 fiW ,‘-f %gä? 1MDB05003-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice Busbar protection ABB Network Control & Protection (810258) I (810260) Features Application (880568) • Percentage restraint bus differential relay |
OCR Scan | ||||
| asea | A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay |
OCR Scan | ||||
| rxma 2 | Sk S§ ■ § Auxiliary, flag and —— tripping relays i m d b 08003- e n March 1991 Changed since August 1990 Data subject to change without notice ASEA BROWN BOVERI ABB Network Control & Protection RXMA 1 RXMA 2 Features Application (90612) RXSF1 (820263) |
OCR Scan | ||||
| brown boveri | JLII1I MPP ASEA BROWN BOVERI B03-1111E Type RXME 18 Page 1 January 1989 Heavy-duty auxiliary relay with target, 2 contacts Changed since June, 1982 Data subject to change without notic( ABB Relays Abstract • Hand-reset target • DC voltage operated • 2 heavy-duty contacts: |
OCR Scan | ||||
|
|
||||||
| b03-1113 | À Ï p Sp ASEA BROWN BOVERI ABB Relays Abstract Application B03-1113E Type RXMK 1 Page 1 January 1987 Heavy-duty auxiliary relay, 4 contacts Changed since June 1982 Data subject to change without notice • AC voltage operated • no or nc contacts • 5 VA maximum power consumption after |
OCR Scan | ||||
| brown boveri | AMI ASEA BROWN BOVERI Type RXME 1 B03-1110E Page 1 June 30, 1982 Data subject to change without noti Heavy-duty auxiliary relay, 2 or 4 contacts ABB Relays Abstract *s Application • Self-reset • DC voltage operated • 2 or 4 heavy-duty contacts: no and nc |
OCR Scan | ||||
| 011-ben | il II II A D V R X EG 21 and R A EG 1MRK 509 011-BEN Voltage relay and protection assemblies February 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (S E 9 4 07 13) Features • Single- and three-phase versions for over- or |
OCR Scan | ||||
| radss | n i l IB I I Type RADSS jp ^ |p |p uitrahigh-speed bus ASEA B R O W N B O VER I c iif f S T G n tid l B03-6010E f g |^ y Data subject to change without notice ABB Relays o o (810258) Abstract Application ) • Protection for buses or short lines |
OCR Scan | ||||
| raaam | Info-No. INFORM ATION v I B I B F ro m /D a te RFR, Oct 1981 Edition I ASEA B R O W N BO VERI RK 851 -305 E Reg. Pa ge 5651 _ . ABB Relays RECLOSING RELAY TYPE RAAAM Single shot single-phase or three-phase reclosure Fig. 1. Reclosing relay RAAAM GENERAL (810892) |
OCR Scan | ||||
| Bus differential relay using auxiliary summation | Bus differential relay using auxiliary summation CT’s REB 101 1-phase 1MRK 505 006-BEN Page 1 Issued: September 2006 Revision: C Data subject to change without notice (SE970178) Features • Percentage restrained differential relay for phase-to-phase and phase-to-earth faults |
Original | ||||
| combiflex | Generator protection COMBIFLEX 1MRK 502 003-BEN Page 1 Issued June 2004 Revision: A Data subject to change without notice (SE970128) Features • Great flexibility in mounting and wiring • Can be delivered as prewired and factory tested protection assemblies or as individual relays |
Original | ||||
| Bus differential relay REB 103 3-phase 1MRK 505 | Bus differential relay REB 103 3-phase 1MRK 505 007-BEN (SE970146) Page 1 Issued: September 2006 Revision: C Data subject to change without notice Features • Percentage restrained differential relay for phase-to-phase and phase-to-earth faults. • Very high E/F-sensitivity of the differential |
Original | ||||
| raaam | ASEA B R O W N BO VERI Type RAAAM Single-shot, single-phase or three-phase reclosing relay for transmission lines B03-8014E ' Datasubtecttochangewithoutnot.ee M m Abstract Application • Delayed breaker reclosing after initiation from protective relay • Four-mode selector switch for single |
OCR Scan | ||||
| Âl il _ M IP II ASEA B R O W N BOVERI Abstract | Âl il _ M IP II ASEA B R O W N BOVERI Abstract Page 1 January 1 98 5 Double-shot, single-phase or three-phase reclosing relay for transmission lines • Delayed breaker reclosing after initiation from protective relay • Four-mode selector switch for single |
OCR Scan | ||||
| rxma1 | Auxiliary, signalling and tripping relays RXMA1, RXMA 2, RXMM 1 RXMS 1, RXSF 1, RXME 1, RXME 18, RXMH 2 & RXMT 1 RXMM 1 (SE 90 06 16) RXSF 1 (SE 82 02 62) (SE 82 02 62) (SE 94 07 44) (SE 94 07 41) Page 1 Issued July 2007 Revision: B Data subject to change without notice |
Original | ||||