ABB RXIG Search Results
Documents mentioning ABB RXIG
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| rxig 21 | ABB ASEA B R O W N BO V E RI A66 Relavs Abstract Application -------------------------------------------------------------------- — ---------------------------------------- — IT Type RXIG 21 B03-2032Ey I Instantaneous ac over- and undercurrent relays |
OCR Scan | ||||
| rxig 21 | A IIII | l | | l l ASEA BROWN BOVERI Instantaneous or definitetime ac overcurrent relay assemblies (RXIG 21, 22, 28) B03-2035E ^ ; 1989 Data subject to change without notice ABB Relays (830504) Abstract Application • Single-phase, two-phase or three-phase |
OCR Scan | ||||
| asea | H4k »>1 l1l ASEA BROWN BOVERI ABB Relays Abstract v Application ---------------------- Type RXIG 22…i . . Harmonic desensitized instantaneous ac over- and undercurrent relays i Data subject to change without notic • 0.01 to 1.5 A total range for 6 models |
OCR Scan | ||||
| m. »11 MMV | m. »11 MMV ______________________________________________________________________________ Selection guide B03-0240E Generator protection ABB Relays Data subject to change without notice Turbo generators < 5 MVA air-cooled 5 - 8 0 MVA air-cooled 8 0 -1 5 0 MVA |
OCR Scan | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| brown boveri | Ali ASEA BROWN BOVERI ABB Relays Abstract Application Type RAGEA 100 % generator stator ground-fault relay • Complete ground-fault protection for gen erator stators that are high impedance grounded • Monitors integrity of the neutral grounding and associated wiring |
OCR Scan | ||||
| shunt reactor | Selection Guides Shunt reactor protection 1MRK501 013-BEN Page 1 November 1995 Changed since March 1992 Replaces 1MDB01002-EN Data subject to change without notice ABB Network Partner Shunt reactor protection *s Application notes The types of reactors considered are the com |
OCR Scan | ||||
| relay | II I I 81 m m aseabro ™ eri ABB Relays Abstract v Application Design _____________________________________________ ____________________________ T y p e R X |G B03-2034E 28 Sensitive instantaneous ac over - and undercurrent relays • 0.25 mA to 300 mA total range for 9 |
OCR Scan | ||||
| ragpc | Gil» Mil» ASEA BROWN BOVERI ABB Relays Abstract Application Design Type RAGPC B03-4013E Loss-of-excitation relay for . , synchronous generators Changed since January 1985 Data subject to change without notice » ■ • Alarm for underexcitation and trip for lossof-excitation |
OCR Scan | ||||
| 'I Selection Guides 1MRK501 011-BEN Page 1 | 'I Selection Guides 1MRK501 011-BEN Page 1 November 1995 Motor protection Changed since March 1992 Replaces 1MDB01002-EN Data subject to change without notice ABB Network Partner M o to r p ro tectio n Application notes The protection system for motors is dependent |
OCR Scan | ||||
| rxig 21 | IL Hi li M IIII ASEA BROWN BOVERI ABB Relays Abstract Application Busbar relays with blocking functions (RXIG 21, RXIL 24, RXIDF 2H, RACIC) • Three-phase overcurrent relay • One or two time steps The energy released as an arc at a short-circuit on a busbar is directly proportional to the short |
OCR Scan | ||||
| rxil 2 | Il il li f*lplp ASEA BROWN BOVERI ABB Relays Type RXIL 22 Harmonic desensitized electromechanical instantaneous ac overcurrent relay Abstract 0.01 to 20 A total range for multiple mod els High accuracy: ± 2 % consistency of operating value ± 3 % graduation and setting error |
OCR Scan | ||||
| rxil 2 | M IP II ASEA BROWN BOVERI ABB Relays Abstract V Application -- Type RXIL 20 Electromechanical instantaneous ac and dc undercurrent relays B03-2011E w • 0.01 to 20 A total range for 9 models • High accuracy: ± 2 % consistency of operating value ± 3 % graduation error |
OCR Scan | ||||
| rakzb | Type RAKZB Impedance protection relay 1 M G B i? )9 0 1 6 -E N Page 1 March 1992 Changed since August 1990 Data subject to change without notice ASEA BROWN BOVERI ABB Network Control & Protection (830243) Features Application Design • Single and two zone versions |
OCR Scan | ||||
|
|
||||||
| rxic 1 | là li m ASEA BROWN BOVERI ABB Relays A bstract s Application Design Type RXIC 1 I 1 High-speed electromechanical instantaneous ac or dc overcurrent relays &KE. Dalasub|ectt0chan9ewthoutnotce • 5 —10 ms operating time • 0.05 to 125 A total range for 10 models |
OCR Scan | ||||
| asea | A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay |
OCR Scan | ||||
| A lI » ABB Relays Abstract B03-9131I e Type | A lI » ABB Relays Abstract B03-9131I e Type RXTBEA 2 Page 1 January 1987 symmetrical components • Measuring negative or positive sequence voltage Q <K Application The RXTBEA 2 voltage filter is used for measur ing or controlling the negative or positive se |
OCR Scan | ||||
| rakzb | All II Ml»» RAKZB Impedance protection relay 1MRK 509 014-BEN Page 1 February 1997 Changed since November 1995 Data subject to change without notice ABB Network Partner (SE 83 02 44) Features • Single and two zone versions • Circular or modified lens characteristics with |
OCR Scan | ||||
| current relay data table b03-2003e | A H II /■ M IR A S E A B R O W N B O VE R I Current relay data table B03-2003E January 1987 Changed since January 1985 Data subject to change without notici ABB Relays Undercurrent relays Static Electromechanic.' RXIG 21 -2032E 50-60 Hr RXIG22 - ?011B" 5 0 -6 0 H ? |
OCR Scan | ||||
| 1mdb04011-en | Type RAYA Voltage regulating relay for tap changer control ASEA BROWN BGVEfii 1MDB04011-EN Page 1 March 1992 Changed since August 1990 Data subject to change without notice ABB Network Control & Protection a i 1 , 0 á lú i- . ¿i M Irtfl ÌO í)O I¿ . a > |
OCR Scan | ||||
| radsl | m i RADSL 1M RK 506 010-BEN Cu-Pilot-Wire Differential Protection Page 1 April 1997 Changed since November 1995 D el* subject to change without notice ABB Network Partner (S E 90 08 45) Features •High-speed operation, 10-30 ms >Current only system - no VT’s required |
OCR Scan | ||||
| rxil 2 | _a t » M W ASEA BROWN BOVERI Types RXIL 23, 24 ABB Relays Abstract K B03-2013E Page 1 January 1987 Electromechanical instantaneous ac and dc overcurrent relays Changed since June 1982 Data subject to change without notic • 2.5 mA to 20 A total range for 10 RXIL 23 |
OCR Scan | ||||
| ASEA B RO W N BOVERI Type RAYA B03.5210 Voltage | ASEA B RO W N BOVERI Type RAYA B03.5210 Voltage regulating relay for Page 1 January 1985 Changed since May 1983 Data subject to change without noti t r a f lS f O r iT IG r S ABB Relays Abstract Application • Accurate regulation of tap changers • Parallel control of two or more power |
OCR Scan | ||||
| ragpc | J L li I I 1 lrlc"Nn RX 641-303 E INFORMATION iS E i BRO W N BCVERI F r o m /B a te <*09- RER, August 1973 ABB Refays E ditio n l F>age 7452 m * rk X' 00-90 Section 6 Loss-of-field relays type BAGPA and RAGPC for synchronous generators _____________ ______________________________ |
OCR Scan | ||||
| rakzb | là I I I I U U E R A bE A B R O W N BUVfcHI Type RAKZB B03-3213E Three-phase impedance f© | 3 y 0313 SUb*eCt 10 chan9e wi,ho‘ ABB Relays (8 3 0 2 4 3 Abstract Application • One and two zone versions • Offset circular MHO or modified lens char acteristic, 60° or 75° |
OCR Scan | ||||