ABB RAAAM Search Results
Documents mentioning ABB RAAAM
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| razoa | ABB A SEA B R O W N B O V E R I ABB Relays Abstract Application Type RAZOA # Three-zone, phase and grOlind distance relay for transmission lines • Three-phase and ground, three-zone se quential measurement distance relay for overhead lines and cables • Independent X and R reach settings |
OCR Scan | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| A lili #%■•!» ASEA BROWN BOVERI Type RASD | A lili #%■•!» ASEA BROWN BOVERI Type RASD B03-8112E Page 1 May 1983 Data subject to change without notic J r ^ Voltage-check relay ABB Relays Abstract Application • Permits circuit breaker closing for “live” bus and “dead” line or “live” line and |
OCR Scan | ||||
| asea | A »11 ASEA BROWN BOVERI ABB Relays Index of IEEE device function numbers with associated ASEA relays B03-0312E Page 1 January 1985 Changed sin ce M ay 1983 Ref: ANSI/IEEE C37.2-1979 Device number Function Type B03 number 2 Time-delay starting or closing relay |
OCR Scan | ||||
| raaam | Info-No. INFORM ATION v I B I B F ro m /D a te RFR, Oct 1981 Edition I ASEA B R O W N BO VERI RK 851 -305 E Reg. Pa ge 5651 _ . ABB Relays RECLOSING RELAY TYPE RAAAM Single shot single-phase or three-phase reclosure Fig. 1. Reclosing relay RAAAM GENERAL (810892) |
OCR Scan | ||||
| razog | V Al l i l i A* IP IP ASEA BROWN BOVERI ABB Relays Type RAZOG B03-7013E Three-zone, phase and ground distance relay for transmission lines Abstract Application Data subject to change without notice >Three-phase and ground sequential mea surement distance relay for overhead lines |
OCR Scan | ||||
| 8111e | Ék I» I I # * W I» Type RASC Synchronism-check relay ASEA BROWN BOVERI B03-8111E Page 1 January 1987 Changed since January 1985 Data subject to change without notic ABB Relays Abstract Application • Measures the difference in magnitude (A U), phase angle ( A cp) and frequency (A f) of |
OCR Scan | ||||
| Info-No. INFORMATION From /Date asea b ro w n b o | Info-No. INFORMATION From /Date asea b ro w n b o v e ri \ RFR, February 1982 Edition 1 ABB Relays RK 862-302 E Reg. Page 5891 1 Replaces Cat. RK 86-11 E Synchro-check relay type RASC o Used for controlled connection of parts of a network th at is already interconnected. |
OCR Scan | ||||
| raaam | ASEA B R O W N BO VERI Type RAAAM Single-shot, single-phase or three-phase reclosing relay for transmission lines B03-8014E ' Datasubtecttochangewithoutnot.ee M m Abstract Application • Delayed breaker reclosing after initiation from protective relay • Four-mode selector switch for single |
OCR Scan |