ABB DC SWI Search Results
ABB DC SWI Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| DCH010505DN7 | Texas Instruments | Miniature, 1W, 3kVDC Isolated DC/DC Converters 5-SIP MODULE -40 to 85 |
|
|
|
| DCP010512DBPE4 | Texas Instruments | Miniature, 1W Isolated Unregulated DC/DC Converters 7-PDIP -40 to 100 |
|
|
|
| DCP011515DBP | Texas Instruments | Miniature, 1W Isolated Unregulated DC/DC Converters 7-PDIP -40 to 100 |
|
|
|
| DCP012415DBP-U/700 | Texas Instruments | Miniature, 1W Isolated Unregulated DC/DC Converters 7-SOP -40 to 100 |
|
|
|
| DCP020507U/1K | Texas Instruments | Miniature, 2W Isolated Unregulated DC/DC Converters 12-SOP -40 to 85 |
|
|
Documents mentioning ABB DC SWI
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| ABB Review The corporate technical journal of the | ABB Review The corporate technical journal of the ABB Group www.abb.com/abbreview 3 / 2008 Pioneering spirits Power electronics revolution in high dc current IGBT: aA tiny chip with a huge impact page 19 measurement page 6 Team-mates: MultiMove functionality |
Original | ||||
| razfe | A*6EAunoviNemem B B “ 7.3 Hiiyy 43993 E rteg RFRj April 1978 Pa3e ABB Relays PC/DC CONVERTOR TYPE 'RTQA ISO GENERAL DC/DC convertor type'RTQA ISO is used as a supply unit in distance relay RAZFE and in directional wave detector RALDA. The convertor supplies the internal static circuits with |
OCR Scan | ||||
| rxke 1 | Jk nil M l » ASEA BROWN BOVERI _______________________________________________________________________________________ 303 ^ 3 ^ ^ ABB Relays January 1985 Function Type B03 num b! AC-DC converter, 20 W AC conversion unit for RXKE 1 time-delay relay All or nothing relays, instantaneous, see auxiliary relays |
OCR Scan | ||||
| Solar inverters ABB string inverters | Solar inverters ABB string inverters PVI-10.0-I-OUTD 10kW PV DC + AC Designed for commercial systems, the PVI-10.0, isolated, three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable |
Original | ||||
| ik mm n ra ASEA BROWN BOVERI ABB Relays Type | ik mm n ra ASEA BROWN BOVERI ABB Relays Type RAAAF Double-shot reclosing relay for transmission and distribution lines Abstract Application • Delayed breaker reclosing after initiation from protective relay • Available in two versions: Version -DC for use with distance relays |
OCR Scan | ||||
| Solar inverters ABB string inverters | Solar inverters ABB string inverters PVI-12.0-I-OUTD 12kW PV DC + AC Designed for commercial systems, the PVI-12.0-isolated, three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable |
Original | ||||
| latching relay | Type RXMVE 1 A n n A V I , Latching relay, 3 4 or 6 contacts ASEA BROWN BOVERI B03-1512E Page 1 May 1983 Changed since June 1982 Data subject to change without notic ABB Relays • DC voltage pulse to operate or reset DC polarity sensing 2 stable latched positions |
OCR Scan | ||||
| ragra | ÂSS ASEA BROWN BOVERI ABB Relays Abstract Application Type RAGRA Rotor ground-fault relay for excitation voltages up to 1800 V de • Monitors the ground insulation of rotating or static excitation systems for synchron ous machines • Provides selective ac and dc ground fault |
OCR Scan | ||||
| Asymmetrie GTO Thyristors ABB Semiconductors AG I | Asymmetrie GTO Thyristors ABB Semiconductors AG I Patented free-floating silicon technology. — All G TOs are turn-off tested under maxim um ratings. — Excellent trade-off between on-state and switching losses. T yp e and ordering num ber V DRM V DC V RRM •tGQM at C s |
OCR Scan | ||||
| rxmvb | AU B03-1511b Type RXMVB 4 Page 1 October 1986 Changed since January 1985 Data subject to change without notic Heavy-duty latching relay, 14 contacts ASEA BROWN BOVERI ABB Relays Abstract K • AC or DC voltage operated May be electric or hand-operated |
OCR Scan | ||||
| Phase Control and Bi-directionally Controlled | Phase Control and Bi-directionally Controlled Thyristors ABB Semiconductors The work-horse of power conversion Since its introduction almost 50 years ago, the Phase Control Thyristor has been the back-bone of the high power electronics industry. Its field of application ranges from kW DC-drives |
Original | ||||
| Al II II M III9 ASEA BROWN BOVERI ABB Relays | Al II II M III9 ASEA BROWN BOVERI ABB Relays Abstract Type RXKD 2H Pickup time-delay relay with target, 0.75 s to 120 h B03-1612E Page 1 October 1986 Changed since June 1982 Data subject to change without notic DC voltage operated Continuous measurement and |
OCR Scan | ||||
| rxmvb 2 | AH m ASEA BROW N BOVERI 30VERI IIP Type RXMVB 2 B03-1510E Heavy-duty latching relay, 8 contacts January 1987 Changed since January 1985 Data subject to change without notic ABB Relays Abstract • AC or DC voltage operated May be electric or hand-operated |
OCR Scan | ||||
| 2cdg | Binary Input, 8-fold, 230 V AC/DC, MDRC BE/S 8.230.1, 2CDG 110 054 R0011 ABB i-bus ® EIB / KNX 2CDC 071 595 F0004 The 8-fold Binary Input BE/S 8.230.1 with manual operation is a rail mounted device for insertion in the distribution board. The device is suitable for |
Original | ||||
|
|
||||||
| cs31 | 4.5 Digital output module ICSO 08 Y1, 8 channels 24 V DC, 2 A Outputs ande CS31 system bus interface electrically isolated 1 2 3 4 5 6 7 1 ICSO08Y1 24VDC I/O REMOTE UNIT ABB Procontic CS31 Unit error 3 Supply error 6 1 Bus error 4 Overload 7 2 2 5 Output TEST |
Original | ||||
| rxke 1 | Êkn i l r\m m ASEA BROWN BOVERI Type RXKE 1 Pickup time-delay relay, 20 ms to 99 s B03-1613E Page 1 June 30, 1982 Data subject to change without noti ABB Relays Abstract v • DC voltage operated • Continuous m easurem ent or summation measurement • 20 ms to 99 s in the same relay |
OCR Scan | ||||
| 5STF 09D1420 5STF 09D1420 Old part no. TR | 5STF 09D1420 5STF 09D1420 Old part no. TR 907-850-14 Fast Thyristor Properties § Amplifying gate § High operational capability § Optimized turn-off parameters Applications § Power switching applications Key Parameters V DRM, V RRM = 1 400 I TAV = 847 I TSM = 13.0 |
Original | ||||
| 5STF 05D2625 5STF 05D2625 Old part no. TR | 5STF 05D2625 5STF 05D2625 Old part no. TR 907F-530-26 Medium Frequency Thyristor Properties § Amplifying gate § High operational capability § Optimized turn-on and turn-off parameters § High operating frequency Applications § Power switching applications |
Original | ||||
| 5stf | 5STF 15F2040 5STF 15F2040 Old part no. TR 918F-1490-20 Medium Frequency Thyristor Properties § Amplifying gate § High operational capability § Optimized turn-on and turn-off parameters § High operating frequency Applications § Power switching applications |
Original | ||||
| 5STF 07T1414 5STF 07T1414 Old part no. TR | 5STF 07T1414 5STF 07T1414 Old part no. TR 907FC-740-14 Medium Frequency Thyristor Properties § Amplifying gate § High operational capability § Optimized turn-on and turn-off parameters § High operating frequency Applications § Power switching applications |
Original | ||||
| 5stf 16f1413 | 5STF 16F1413 5STF 16F1413 Old part no. TR 918F-1590-14 Medium Frequency Thyristor Properties § Amplifying gate § High operational capability § Optimized turn-on and turn-off parameters § High operating frequency Applications § Power switching applications |
Original | ||||
| tr 907f-570-14 | 5STF 06D1408 5STF 06D1408 Old part no. TR 907F-570-14 Medium Frequency Thyristor Properties Amplifying gate High operational capability Optimized turn-on and turn-off parameters High operating frequency Applications Power switching applications |
Original | ||||
| 5STF 07D1414 5STF 07D1414 Old part no. TR | 5STF 07D1414 5STF 07D1414 Old part no. TR 907F-740-14 Medium Frequency Thyristor Properties § Amplifying gate § High operational capability § Optimized turn-on and turn-off parameters § High operating frequency Applications § Power switching applications |
Original | ||||