ABB 800 TRANSMITTE Search Results
ABB 800 TRANSMITTE Result Highlights (5)
| Part | ECAD Model | Manufacturer | Description | Download | Buy |
|---|---|---|---|---|---|
| QXP27A4-10D | Amphenol Communications Solutions | 40G QSFP+ LR4 | |||
| COMBOSENSOR | Texas Instruments | XTR117 XTR117 4-20mA Current Loop Transmitter |
|
||
| DIT4096IPW | Texas Instruments | 96kHz Digital Audio Transmitter 28-TSSOP -40 to 85 |
|
|
|
| DIT4096IPWR | Texas Instruments | 96kHz Digital Audio Transmitter 28-TSSOP -40 to 85 |
|
|
|
| DIT4192IPW | Texas Instruments | 192 kHz Digital Audio Transmitter 28-TSSOP -40 to 85 |
|
|
Documents mentioning ABB 800 TRANSMITTE
| Document | Partial File Text | Tags | Type | |||
|---|---|---|---|---|---|---|
| 267cs | Data Sheet 2101155-AI XMV Multi-Variable Transmitter Overview INTRODUCTION The ABB XMV (267CS/269CS) measures Static Pressure, Differential Pressure, and Process Temperature in a vapor or liquid media. The XMV (multi-variable transmitter) is a two - wire RS 485 |
Original | ||||
| Technical catalog ABB molded case circuit | Technical catalog ABB molded case circuit breakers UL 489 and CSA C22.2 Standard ABB SACE S.p.A An ABB Group company L.V. Breakers Via Baioni, 35 24123 Bergamo, Italy Tel.: +39 035.395.111 - Telefax: +39 035.395.306-433 http://www.abb.com ABB molded case circuit breakers - UL 489 and CSA C22.2 Standard |
Original | ||||
| 5shz 08f6000 | VDRM VRRM ITGQM VT0 rT = = = = = 6000 6000 800 3.25 6.4 V V A V Reverse Blocking Integrated Gate-Commutated Thyristor 5SHZ 08F6000 mΩ Doc. No. 5SYA1231-01 Sep. 01 • Optimized for current source inverter (CSI) • Fast response (tdon < 3 µs, tdoff < 7 µs) |
Original | ||||
| 5shz 15h6000 | VDRM VRRM ITGQM VT0 rT = = = = = 6000 6000 1500 2.95 3.55 V V A V Reverse Blocking Integrated Gate-Commutated Thyristor 5SHZ 15H6000 mΩ PRELIMINARY Doc. No. 5SYA1237-01 Nov. 01 • Optimized for current source inverter (CSI) • Fast response (tdon < 3.3 µs, tdoff < 6 µs) |
Original | ||||
| Key Parameters VDRM = 5500 ITGQM = 1800 ITSM = 17 | Key Parameters VDRM = 5500 ITGQM = 1800 ITSM = 17 VT0 = 1.5 rT = 0.83 VDClink = 3300 V A kA V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 19L6004 PRELIMINARY mΩ V Doc. No. 5SYA 1220-03 Feb. 99 • Features |
Original | ||||
| Key Parameters VDRM = 4500 ITGQM = 2200 ITSM = 18 | Key Parameters VDRM = 4500 ITGQM = 2200 ITSM = 18 VT0 = 1.47 rT = 0.59 VDClink = 2800 V A kA V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 26L4502 PRELIMINARY mΩ V Doc. No. 5SYA 1221-03 Feb. 99 • Features |
Original | ||||
| flowmeter | Data Sheet DS/WM Issue 5 Electromagnetic Flowmeter WaterMaster The most stable transmitter in the world – self-calibrating transmitter and ultra-low temperature coefficient for highest accuracy One solution for all your needs – designed for use in all water and waste water |
Original | ||||
| VDRM ITGQM ITSM VT0 rT VDClink = = = = = = 5500 | VDRM ITGQM ITSM VT0 rT VDClink = = = = = = 5500 1800 16.1 1.65 1 3300 V A kA V Reverse Conducting Integrated Gate-Commutated Thyristor mΩ V PRELIMINARY 5SHX 19L6005 Doc. No. 5SYA1229-01 Feb. 02 • Direct fiber optic control and status • Fast response (tdon < 3 µs, tdoff < 6 µs) |
Original | ||||
| With effect from 2nd January 2014 Low Voltage | With effect from 2nd January 2014 Low Voltage Products Price list ABB low voltage products ABB is a global leader in power and automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. ABB |
Original | ||||
| Specification sheet Deltapi N Series Pneumatic | Specification sheet Deltapi N Series Pneumatic Transmitters Model NAD Differential pressure transmitter GENERAL CHARACTERISTICS The blind type differential pressure transmitter, mod. NAD, is used to measure and convert a differential pressure value into a proportional pneumatic signal. |
Original | ||||
| 26l4503 | VDRM ITGQM ITSM VT0 rT VDClink = = = = = = 4500 2200 18.8 1.65 0.6 2800 V A kA V mΩ V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 26L4503 Doc. No. 5SYA 1230-01 Aug. 2000 • Direct fiber optic controll and status • Fast response (∆tdon < 3 µs, tdoff < 6 µs) |
Original | ||||
| Specification sheet Deltapi N Series Pneumatic | Specification sheet Deltapi N Series Pneumatic Transmitters Model NBC Absolute pressure transmitter GENERAL CHARACTERISTICS The blind type absolute pressure transmitter, mod. NBC, is used to measure an absolute pressure and convert it into a proportional pneumatic signal. |
Original | ||||
| deltapi | Specification sheet Deltapi N Series Pneumatic Transmitters Model NAD Differential pressure transmitter GENERAL CHARACTERISTICS The blind type differential pressure transmitter, mod. NAD, is used to measure and convert a differential pressure value into a proportional pneumatic signal. |
Original | ||||
| zirconia oxygen | Data Sheet SS/EXFG/GP Hazardous Area Zirconia Oxygen Systems Issue 9 EXFG & EXGP Hazardous area certification – ATEX II 2G EEx d IIB T3 (T amb -20° to +50°C) In situ probe for high speed measuring of excess oxygen – continuous uninterrupted on-line measurement |
Original | ||||
|
|
||||||
| 1sdc210004d0203 | Technical catalogue Tmax Low voltage moulded-case circuit-breakers up to 630 A Preliminary - 1SDC210004D0203 OVERVIEW MAIN CHARACTERISTICS THE RANGES ACCESSORIES CHARACTERISTIC CURVES AND TECHNICAL INFORMATION WIRING DIAGRAMS OVERALL DIMENSIONS ORDERING CODES |
Original | ||||
| VDRM ITGQM ITSM V(T0) rT VDC-link = = = = = = | VDRM ITGQM ITSM V(T0) rT VDC-link = = = = = = 4500 1100 8.8×103 1.65 1.2 2800 V A A V mΩ V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 14H4510 PRELIMINARY Doc. No. 5SYA1227-05 Aug 07 • High snubberless turn-off rating • Optimized for medium frequency (<1 kHz) and |
Original | ||||
| VDRM ITGQM ITSM V(T0) rT VDC-link = = = = = = | VDRM ITGQM ITSM V(T0) rT VDC-link = = = = = = 5500 900 7.5×103 1.65 2 3300 V A A V mΩ V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 10H6010 PRELIMINARY Doc. No. 5SYA1226-05 Aug 07 • High snubberless turn-off rating • Optimized for medium frequency (<1 kHz) and |
Original | ||||
| d-ts-v10186 | Data Sheet D-TS-V10186_2 IT Field Temperature Measurement Products Heavy Duty Spring Loaded Sensor Assembly with Transmitter - Series V10186 n Design - Can be build from standardized components - Standard lengths for fewer spare parts on stock - Immersion lengths can be selected |
Original | ||||
| Specification sheet Deltapi N Series Pneumatic | Specification sheet Deltapi N Series Pneumatic Transmitters Model NBC Absolute pressure transmitter GENERAL CHARACTERISTICS The blind type absolute pressure transmitter, mod. NBC, is used to measure an absolute pressure and convert it into a proportional pneumatic signal. |
Original | ||||
| ABB review A world in transformation 6 Power | ABB review A world in transformation 6 Power below the waves 33 Transforming industry 45 Sustainable and available 64 Special Report Transformers The corporate technical journal Transformers are essential pieces of electrical equipment that help to transmit |
Original | ||||
| VDRM ITGQM ITSM V(T0) rT VDC-link = = = = = = | VDRM ITGQM ITSM V(T0) rT VDC-link = = = = = = 4500 630 5×103 1.8 2 2800 V A A V mΩ V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 08F4510 PRELIMINARY Doc. No. 5SYA1223-06 Aug 07 • High snubberless turn-off rating • Optimized for medium frequency (<1 kHz) and |
Original | ||||
| VDRM ITGQM ITSM VT0 rT VDClink = = = = = = 4500 | VDRM ITGQM ITSM VT0 rT VDClink = = = = = = 4500 2200 18.8 1.65 0.6 2800 V A kA V Reverse Conducting Integrated Gate-Commutated Thyristor 5SHX 26L4503 mΩ V Doc. No. 5SYA1230-01 Sep. 01 • Direct fiber optic controll and status • Fast response (tdon < 3 µs, tdoff < 6 µs) |
Original | ||||
| Specification sheet Deltapi N Series Pneumatic | Specification sheet Deltapi N Series Pneumatic Transmitters Model NDC Absolute pressure transmitter GENERAL CHARACTERISTICS The blind type absolute pressure transmitter, mod. NDC, is used to measure an absolute pressure and convert it into a proportional pneumatic signal. |
Original | ||||
| 5SSA 5SSA Old part no. S 833 Silicon Surge | 5SSA 5SSA Old part no. S 833 Silicon Surge Voltage Suppressor Properties § Diffused pnp – Si structure § hermetically sealed in metal-ceramic package § Available to protect power devices (thyristors) against small and medium power surges (e.g. 200 kW over 10 μs) |