The Datasheet Archive

UL544 Datasheets Context Search

Catalog Datasheet MFG & Type PDF Document Tags
ES5S3000

Abstract: p2.15.200w sp5902 SP5920W 12200W SP592 12D200W
Text: specifically modified to meet the severe dem ands of UL544. All models utilize a Faraday shielded power , CIRCUITS UL544 Standard for Safety - Medical & Dental Equipment · PATIENT CO N TACT RATED (W D ESIGNATOR) · 2500 Vac BREAKD O W N · FARADAY-SHIELDED T R A N S FO R M E R S The UL544 Series consists of , as defined by Underwriters Laboratories, Inc., under UL544 ; STA N D A RD for SA FET Y - M ED ICA L , processor controlled blood analyzers are just a few of the many applica tions utilizing UL544 units


OCR Scan
PDF B3D31S4 00D0723 UL544 UL544 UL544; E50975 4-40x0 ES5S3000 p2.15.200w sp5902 SP5920W 12200W SP592 12D200W
sp5902-2

Abstract: sp5902 ecw12 ecw12-120 ESW11-150 p2.15.200w pw22-020 UL544 sp5902-2w ES12S1200W
Text: demands of UL544. All models utilize a Faraday shielded power transformer which holds AC leakage current , EMERSON/ SEMICONDUCTOR SE 33D3154 DD00723 □ -p. SEMICONDUCTOR CIRCUITS UL544 Standard for , BREAKDOWN • FARADAY-SHIELDED TRANSFORMERS The UL544 Series consists of more than 250 power supply models , Laboratories, Inc., under UL544 ; STANDARD for SAFETY — MEDICAL and DENTAL EQUIPMENT. All models are , microprocessor controlled blood analyzers are just a few of the many applications utilizing UL544 units. Although


OCR Scan
PDF 33D3154 DD00723 UL544 UL544 UL544; E50975 UL544. 4-40x0 H-0306? sp5902-2 sp5902 ecw12 ecw12-120 ESW11-150 p2.15.200w pw22-020 sp5902-2w ES12S1200W
2000 - FA601

Abstract: No abstract text available
Text: H Series RFI Power Line Filters for UL544 Healthcare Equipment EH8 EH9 UL Recognized under UL544 CSA Certified VDE and SEV* Approved EH1 EH4/EH4C EH5 H Series Corcom H series filters were developed specifically for health care applications. These products are suitable for uses in both patient care equipment and nonpatient care equipment. Their extremely low leakage current allows compliance with UL544 and CSA 22.2 health care specifications. See Appendix C for more information on UL544


Original
PDF UL544 10EH4C fre98 10EH4 10EH4C 15EH4 GA400 FA601
Not Available

Abstract: No abstract text available
Text: H Series RFI Power Line Filters for UL544 Healthcare Equipm ent we 'DVE UL Recognized Under UL544 , CSA C ertified, VDE and S EVt Approved H Series Specifications Corcom H Series filte rs were developed sp e cifica lly fo r health care applications. These products are suitable fo , leakage current allow s com pliance w ith UL544 and CSA 22.2 health care specifications. Maximum , ation on UL544 health care specifications. O perating frequency: The H series feature products w


OCR Scan
PDF UL544 UL544, 1500VAC 1450VDC UL544 GA400, GA400: 10EH4, 10EH4C
6J4 CORCOM

Abstract: corcom 6J4 GA400 JA411 rfi power line filter corcom 6vj1 UL544
Text: General Purpose Applications for UL544 Health Care Equipment J Series Front View, All Models 6J4 , with lineto-ground capacitors. Designed to allow equipment to meet UL544 medical specifications for , more information on UL544 specifications, see Appendix C. Note: When using the models with an IEC , filter for susceptibility applications Note 2: Medical line filter for very low leakage UL544 health , Applications for UL544 Health Care Equipment (Continued) J Series Electrical Schematics Specifications


Original
PDF UL544 JA411 JA412 JA413 JA414 JA415 JA416 JA417 JA418 JA419 6J4 CORCOM corcom 6J4 GA400 JA411 rfi power line filter corcom 6vj1
6j1 corcom

Abstract: 6J4 CORCOM JA411 UL544 GA400 312 fuse 2A filter 220V 60 Hz 220v 20v 4a Fuse 240V 30 A Fuse 220V 1A
Text: General Purpose Applications for UL544 Health Care Equipment J Series Front View, All Models 6J4 , with lineto-ground capacitors. Designed to allow equipment to meet UL544 medical specifications for , more information on UL544 specifications, see Appendix C. Note: When using the models with an IEC , filter for susceptibility applications Note 2: Medical line filter for very low leakage UL544 health , Applications for UL544 Health Care Equipment (Continued) J Series Electrical Schematics Specifications


Original
PDF UL544 JA410 JA411 JA412 JA413 JA414 JA415 JA416 JA417 JA418 6j1 corcom 6J4 CORCOM JA411 GA400 312 fuse 2A filter 220V 60 Hz 220v 20v 4a Fuse 240V 30 A Fuse 220V 1A
6J4 CORCOM

Abstract: corcom 6vj1 220v 20v 4a corcom 6J4 filter 220V 60 Hz JA411 JA-500 105125 rfi power line filter transformer 1A 220V
Text: General Purpose Applications for UL544 Health Care Equipment J Series UL Recognized CSA Certified , capacitors. Designed to allow equipment to meet UL544 medical specifications for patient care and , General purpose filter for susceptibility applications. 2 Medical line filter for very low leakage UL544 , UL544 Health Care Equipment (Continued) J Series 6VJ1/6VJ1-2 Terminal View 6HJ4-4/6HJ4-2 , Optional RFI Power Line Filter for General Purpose Applications for UL544 Health Care Equipment (Continued


Original
PDF UL544 susceptib418 JA419 JA500, 6J4 CORCOM corcom 6vj1 220v 20v 4a corcom 6J4 filter 220V 60 Hz JA411 JA-500 105125 rfi power line filter transformer 1A 220V
NFS40-7908

Abstract: No abstract text available
Text: UL544 medical approvals [ 2 YEAR WARRANTY ] The NFS40 medical series is a 40W universal input AC , , with full medical safety approval to EN60601 and UL544 and the CE mark, meets conducted emissions , VDE0750, IEC601 EN60601 -1, UL544 CSA C22.2 No. 125 270g (9.6oz) MIL-HDBK-217E 170,000 hours 110VAC , Licence No. 2559 UL544 File No. E147937 CSA C22.2 No. 125 File No. LR41062C Relative humidity Altitude , UL544 , CSA22.2 No. 125 and IEC601/VDE0750 standards. The NFS40-79XX series is for use in ordinary


OCR Scan
PDF NFS40 EN60601 UL544 40Wunting NFS40-79XX NFS40-7908
2001 - 10EH1

Abstract: 10EH3 10EH4 10EH4C 15EH4 GA400 UL544
Text: H Series RFI Power Line Filters for UL544 Healthcare Equipment EH8 EH9 UL Recognized under UL544 CSA Certified VDE Approved EH5 EH4/EH4C EH1 H Series Corcom H series filters were developed specifically for health care applications. These products are suitable for uses in both patient care equipment and nonpatient care equipment. Their extremely low leakage current allows compliance with UL544 and CSA 22.2 health care specifications. See Appendix C for more information on UL544


Original
PDF UL544 UL544 10EH4C 10EH1 10EH3 10EH4 10EH4C 15EH4 10EH1 10EH3 10EH4 15EH4 GA400
2001 - UL-544

Abstract: UL544
Text: H Series RFI Power Line Filters for UL544 Healthcare Equipment EH8 EH9 UL Recognized under UL544 CSA Certified VDE Approved EH1 EH4/EH4C EH5 H Series Corcom H series filters were developed specifically for health care applications. These products are suitable for uses in both patient care equipment and nonpatient care equipment. Their extremely low leakage current allows compliance with UL544 and CSA 22.2 health care specifications. See Appendix C for more information on UL544 health


Original
PDF UL544 10EH4C 10EH4 15EH4 10EH1 10EH3 UL-544
8 pin IC 7601

Abstract: NFS50-7908 76XX NFS50 nfs507610 nfs50 7608m NFS50-7610 M/sh 40/085/21/NFS50 nfs50-7601 NFS50-7608
Text: , UL544 EN60601, CSA C22.2 No. 125 400g (14oz) MIL-HDBK-217E, 25°C 160,000 hours 85 to 264VAC 120 to , DIFFERENCES Isolation Approvals Input/output 4000VAC IEC601, EN60601 VDE0750, UL544 CSA C22.2 No. 125 25|jA , approved to UL544 , CSA C22.2 No. 125 and IEC601 standards. It is suitable for use in ordinary, patient-connect applications under the UL544 and CSA 22.2 standards, and authorised for use in non-critical , . E136005 NFS50-7908: UL544 File No. E147937 NFS50-76XX: CSA C22.2 No. 950 File No. LR41062C NFS50


OCR Scan
PDF NFS50 EN55022, EN55011 NFS50-7608M NFS50-7601 NFS50-76XX: VDE0805/EN60950/IEC950/IEC1010 NFS50-7908: 8 pin IC 7601 NFS50-7908 76XX nfs507610 nfs50 7608m NFS50-7610 M/sh 40/085/21/NFS50 nfs50-7601 NFS50-7608
NFS50-7608D

Abstract: NFS42-7610T NFS50-7908 NFS42-7608T NFS50-7608M nfs50 7608m NFS42-7627T NFS42-7610 NFS42 MOLEX 09-50-30-31
Text: frequency N ow With UL544 Approval « · iu 'O 'irn rn e n tltd tor new de sig ns The new NFS42 , approved to UL544 medical standards, and electrically similar and mechanically identical to the NFS507608 , electrical characteristics table). The NFS50-7908 is approved to UL544 (File No. E65890), CSA C22.2-125 (File , is for use in ordinary, patient connected applications under the UL544 and CSA C22.2 standards, and


OCR Scan
PDF NFS42, NFS50 120VDC 370VDC 16mSec 20KHz UL544 NFS42 NFS50-7601 NFS50-7608D NFS42-7610T NFS50-7908 NFS42-7608T NFS50-7608M nfs50 7608m NFS42-7627T NFS42-7610 MOLEX 09-50-30-31
Not Available

Abstract: No abstract text available
Text: arespecifically modified to meet the severe demands of UL544. All models utilize a Faraday shielded power , rating as defined by Underwriters Laboratories, Inc., under UL544 ; STANDARD for SAFETY-MEDICAL and , are just a few of the many applications utilizing UL544 units. Although Underwriters Laboratories maintains strict requirements to ensure the safety of such equipment, UL544 recognized units are not


OCR Scan
PDF UL544; E50975 UL544.
Not Available

Abstract: No abstract text available
Text: equipment specification UL544 is broken down into two basic categories. A. Patient Care Equipment â , ) UL544 nonpatient equipment. 8S613 C22.2 No. 8-1986 Yes Par 5.419 1250 VAC or 1768 VDC3 , . UL2601 has more relaxed leak­ age current requirements than UL544 , allowing increased line-to-ground capacitance and therefore more perfor­ mance. Like UL544 it is divided into 2 categories. A. Patient Care


OCR Scan
PDF 120VAC, UL2601
GA400

Abstract: 10EH1 10EH3 10EH4 10EH4C 15EH4 UL544
Text: H Series EH4/EH4C RFI Power Line Filters for UL544 Healthcare Equipment EH8 UL Recognized under UL544 CSA Certified VDE and SEV* Approved EH9 EH1 H Series Corcom H series filters were developed specifically for health care applications. These products are suitable for uses in both patient care equipment and nonpatient care equipment. Their extremely low leakage current allows compliance with UL544 and CSA 22.2 health care specifications. See Appendix C for more information on UL544


Original
PDF UL544 UL544 10EH4C 10EH1 10EH3 10EH4 10EH4C 15EH4 GA400 10EH1 10EH3 10EH4 15EH4
1999 - flu3-40-3

Abstract: FLU2-40-1 FLU3-40-1AD FLU1-40 flu2-40 LR52335 power-40W MDU-3-40 mdu3-40-1ad FLU3-40-6
Text: Approvals Austel CCL Certification Models with UL544 /CSA C22.2-601/EN60-601 Medical Safety Approvals , 1.0% 0.1% 0.2% - AC-DC Singles To UL544 /EN60-601/CSA 22.2-601.1 MDU1-40-1AD V1 5 , % AC-DC Duals To UL544 /EN60-601/CSA 22.2-601.1 MDU2-40-1AD V1 V2 +5 +12 0.0 0.0 3.00 , % 1.0% 1.0% AC-DC Triples FLU3-40-3AD FLU3-40-4AD FLU3-40-5AD FLU3-40-6AD To UL544 , Series FLU = AC Input MDU = AC Input ( UL544 /IEC601 Safety) DC = DC Input Number of Outputs Output


Original
PDF UL/CSA/EN60950 UL544/CSA 2-601/EN60-601 EN55022/FCC 000-Hour M830-1155 036-inch flu3-40-3 FLU2-40-1 FLU3-40-1AD FLU1-40 flu2-40 LR52335 power-40W MDU-3-40 mdu3-40-1ad FLU3-40-6
Condor

Abstract: XMAT200 power supply FCC
Text: potentially exceed the 100µA UL544 specification limit. The monitor should be UL544 approved and plugged into a separate outlet. AC Cord The AC cord is user-supplied; must be UL544 approved for medical use


Original
PDF XMAT200 180-264Vac, 47-63Hz 115Vac 230Vac. 20MHz 100KHz A/250V 115/230Vac 250mm) Condor power supply FCC
1999 - NFS50-7610

Abstract: NFS50-7608M NFS50-7908 nfs50-7601 NFS50-7608 E147937 LR41062C nfs507610 79XX nfs50 7608m
Text: , UL544 EN60601, CSA C22.2 No. 125 MTBF (See Note 7) 400g (14oz) MIL-HDBK-217E, 25°C 160,000 hours , -7908 SPECIFICATION DIFFERENCES Isolation Approvals Input/output 4000VAC IEC601, EN60601 VDE0750, UL544 CSA , approved to UL544 , CSA C22.2 No. 125 and IEC601 standards. It is suitable for use in ordinary, patient-connect applications under the UL544 and CSA 22.2 standards, and authorised for use in non-critical , NATURAL CONVECTION COOLING NFS50-76XX: UL1950 File No. E136005 NFS50-7908: UL544 File No. E147937


Original
PDF NFS50 20CFM LR41062C NFS50-7908: NFS50-76XX: PS/603174 NFS50-7610 NFS50-7608M NFS50-7908 nfs50-7601 NFS50-7608 E147937 LR41062C nfs507610 79XX nfs50 7608m
lr50913

Abstract: NFS50-7610 NFS50-7908 nfs50-7601 76XX LR41062C NFS50-7608 nfs507610 120vdc 60hz 25w Model 7908
Text: .2-234 Medical IEC601, VDE0750, UL544 EN60601, CSA22.2-125 ±0.03%/°C, max. +5V output Primary power , approved to UL544 , CSA 22.2-125 and IEC601 standards. It is suitable for use in ordinary, patient-connect applications under the UL544 and CSA 22.2 standards, and authorized for use in non-critical , -76XX: UL1950 File No. E136005 NFS50-7908: UL544 File No. E147937 NFS50-76XX: CSA22.2-234/950 File No , , EN60601, VDE0750, CSA22.2-125, UL544 132VAC, 60Hz 25µA, max. 264VAC, 50Hz 50µA, max. EN55022


Original
PDF NFS50 85VAC 264VAC 120VDC 370VDC IEC601 115/230VAC cus50-0164 NFS50-7608 lr50913 NFS50-7610 NFS50-7908 nfs50-7601 76XX LR41062C NFS50-7608 nfs507610 120vdc 60hz 25w Model 7908
Condor

Abstract: XMAT200 CISPR11 CISPR-11 power supply FCC 4565 D c 5929 transistor
Text: to the leakage current of the supply and potentially exceed the 100 µA UL544 specification limit. The monitor should be UL544 approved and plugged into a separate outlet. Overload Protection All , user-supplied; must be UL544 approved for medical use. Fusing 6 A/250 V for 115/230 Vac both lines. Inrush


Original
PDF XMAT200 204-watt, CISPR11 UL2601 IEC601 pk/115 pk/230 Condor CISPR-11 power supply FCC 4565 D c 5929 transistor
10EAH1

Abstract: GA400
Text: Tyco Electronics CORCOM Product Guide For UL544 Health Care Equipment EAH, EBH Series UL Recognized CSA Certified VDE Approved EAH Series This is a new generation of compact medical RFI filters with an IEC socket. A new design in internal structure and manufacturing process makes this series cost , information on UL544 specification is listed in Appendix C. Note: When using the models with an IEC connector , are metric equivalents. to change. Tyco Electronics CORCOM Product Guide For UL544 Health Care


OCR Scan
PDF UL544 FA601 10EAH1 GA400
2000 - NFS50-7610

Abstract: NFS50-7908 nfs50 7608m NFS50-7608M NFS50-7608 NFS50 nfs50 4 pin transistor nfs50-7601 NFS50 7908 LR41062C/LR50913
Text: , VDE0750, UL544 EN60601, CSA C22.2 No. 125 MTBF (See Note 7) 400g (14oz) MIL-HDBK-217E, 25°C 160 , Isolation Approvals Input/output 4000VAC IEC601, EN60601 VDE0750, UL544 CSA C22.2 No. 125 , conducted noise and safety ground leakage current specifications. The NFS50-7908 is approved to UL544 , CSA , under the UL544 and CSA 22.2 standards, and authorised for use in non-critical, non-patient-connect , -76XX: UL1950 File No. E136005 NFS50-7908: UL544 File No. E147937 25W 5W MINIMUM LOAD REQUIRED TO ACHIEVE


Original
PDF NFS50 NFS50 20CFM E147937 NFS50-76XX: LR41062C NFS50-7908: NFS50-7610 NFS50-7908 nfs50 7608m NFS50-7608M NFS50-7608 nfs50 4 pin transistor nfs50-7601 NFS50 7908 LR41062C/LR50913
Transformer 500 volt to 24 a c 24 dc 240 ac volt

Abstract: P575
Text: COMPUTER PRDTS/ POUER TTC D 2313103 00QD3bP =517 CPR T-S1-05 MED 300/500 SERIES Single, Dual and Triple Outputs ■UL544 Approved ■CSA Certified ■Less than 10 mA Leakage ■Split Bobbin Transformer ■2500 VAC Isolation ■Overtemperature Protection The MED 300/500 Series of AC/DC encapsulated power modules meet or exceed the stringent UL544 requirements for patient contact , iMSPmà ucrsi y I l^/ I VI vi. % « POWER PROOLICTS OlVISIOn '1 UL544 Power Modules OUTPUT VOLTAGE1 OUTPUT


OCR Scan
PDF 00QD3bP T-S1-05 UL544 MED302 MED365 MED301 MED396 MED531 MED514 Transformer 500 volt to 24 a c 24 dc 240 ac volt P575
2013 - Not Available

Abstract: No abstract text available
Text: SUP-EH SERIES NOISE FILTERS Features ● Leak current lower than 10μA ( 250VAC, 60Hz ), The best for medical equipment. ● High performance magnetics for pulse absorption. ● High insertion loss characteristics. File No. E78644 LR60681 SE/0142-13 SE/0142-14 Safety Standard UL :UL1283 / UL544 CSA :C22.2, No.8-M1986 SEMKO :EN60939 UL-544 is the standard of medical equipments. The "ENEC" mark is a common European product certification mark based on testing to harmonised


Original
PDF 250VAC, E78644 LR60681 SE/0142-13 SE/0142-14 UL1283 UL544 8-M1986 EN60939 UL-544
2001 - Not Available

Abstract: No abstract text available
Text: H Series - Low Cost Low Cost Medical Filter for UL544 or UL2601 Healthcare Equipment UL Recognized CSA Certified VDE Approved H Series - Low Cost A low cost alternative version of the H series. Provides similar performance in a similar package and at a lower cost. Also offers a wider range of current ratings. Designed specifically for health care applications, these filters are suitable for use , allows compliance with UL544 and UL2601 as well as CSA 22.2 health care specifications


Original
PDF UL544 UL2601 UL2601